Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

被引:24
|
作者
Beyersdorf, PT [1 ]
Fejer, MM [1 ]
Byer, RL [1 ]
机构
[1] Stanford Univ, Ginzton Lab, Stanford, CA 94305 USA
关键词
D O I
10.1364/JOSAB.16.001354
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a free-space common-path polarization Sagnac interferometer. The polarization Sagnac interferometer is used in a symmetric fashion with detection on the dark fringe of the interference to avoid photodetector saturation when high-powered illumination is used. By modulating the carrier field that is reflected from the interferometer, we generate a local oscillator for heterodyne detection of the signal field. We calculate the effect of optical element misalignments and imperfect polarization on the shot-noise-limited sensitivity of the interferometer. The predictions are experimentally verified with a 2-m arm-length tabletop polarization Sagnac interferometer. (C) 1999 Optical Society of America [S0740-3224(99)02609-0].
引用
收藏
页码:1354 / 1358
页数:5
相关论文
共 50 条
  • [1] SPR phase sensitivity enhancement in common-path polarization heterodyne interferometer by polarization tuning
    Aref, Seyed Hashem
    [J]. OPTIK, 2018, 156 : 619 - 627
  • [2] Heterodyne common-path grating interferometer with Littrow configuration
    Wu, Chyan-Chyi
    Hsu, Cheng-Chih
    Lee, Ju-Yi
    Chen, Yan-Zou
    [J]. OPTICS EXPRESS, 2013, 21 (11): : 13322 - 13332
  • [3] SIMPLE HETERODYNE INTERFEROMETRY USING A HOLOGRAPHIC COMMON-PATH INTERFEROMETER
    TOYOOKA, S
    TANAHASHI, T
    TOMINAGA, M
    [J]. APPLIED OPTICS, 1984, 23 (10): : 1460 - 1463
  • [4] A common-path heterodyne interferometer for surface profiling in microelectronic fabrication
    Klein, EJ
    Ramirez, WF
    Hall, JL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (05): : 2455 - 2466
  • [5] Study on the nonlinear error of common-path laser heterodyne interferometer
    Zhao, HJ
    Zhang, GJ
    [J]. RECENT DEVELOPMENTS IN TRACEABLE DIMENSIONAL MEASUREMENTS, 2001, 4401 : 305 - 312
  • [6] Common-path surface plasmon interferometer with radial polarization
    Zhang, Bei
    Zhang, Chengqian
    Somekh, Michael G.
    Yan, Peng
    Wang, Le
    [J]. OPTICS LETTERS, 2018, 43 (14) : 3245 - 3248
  • [7] FORCE MICROSCOPY USING COMMON-PATH OPTICAL-HETERODYNE INTERFEROMETER
    KIKUTA, H
    ASAI, S
    YASUKOCHI, H
    IWATA, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (03): : 587 - 590
  • [8] Practical common-path heterodyne surface profiling interferometer with automatic focusing
    Zhao, HZ
    Liang, R
    Li, DC
    Cao, M
    [J]. OPTICS AND LASER TECHNOLOGY, 2001, 33 (04): : 259 - 265
  • [9] A double common-path heterodyne interferometer for the measurement of flying height modulation
    Lin, Dejiao
    Yue, Zhaoyang
    Song, Nanhai
    Meng, Yonggang
    Yin, Chunyong
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (05)
  • [10] Common-path laser interferometer
    Qu, Xing-hua
    Wang, Li-hua
    Fu, Yun-xia
    [J]. OPTICS LETTERS, 2009, 34 (24) : 3809 - 3811