Motion correction for Simultaneous PET/MR with No Additional MR Sequence

被引:0
|
作者
Wang, Jizhe [2 ]
Feng, Tao [2 ]
Hu, Lingzhi [2 ]
Zhu, Wentao [2 ]
Dong, Yun [1 ]
Li, Hongdi [2 ]
机构
[1] Shanghai United Imaging Healthcare Co Ltd, Shanghai, Peoples R China
[2] UIH Amer Inc, Houston, TX USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
654
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Fast tagged MR acquisition for PET motion correction in simultaneous cardiac PET-MR
    Huang, Chuan
    Petibon, Yoann
    Ouyang, Jinsong
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [2] PET motion correction using simultaneous PET-MR acquisition and MR-derived motion fields
    Tsoumpas, Charalampos
    Mackewn, Jane
    King, Andrew
    Buerger, Christian
    Totman, John
    Schaeffter, Tobias
    Marsden, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 532 - 532
  • [3] PRACTICAL PET RESPIRATORY MOTION CORRECTION IN CLINICAL SIMULTANEOUS PET/MR
    Manber, Richard
    Atkinson, David
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    O'Meara, Celia
    Wan, Simon
    Ourselin, Sebastien
    Arridge, Simon
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1580 - 1583
  • [4] Hybrid MR-guided and PET-guided motion correction of PET images in simultaneous PET/MR
    Feng, Tao
    Ahlman, Mark
    Tsui, Benjamin
    Guo, Liheng
    Guttman, Mike
    McVeigh, Elliot
    Bluemke, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [5] In-vivo studies of tagged MR based PET motion correction in simultaneous PET-MR
    Chun, Se Young
    Moussallem, Elie
    Reese, Timothy
    Guerin, Bastien
    Catana, Ciprian
    Alpert, Nathaniel
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [6] Assessment of motion correction strategies in simultaneous PET-MR
    Chun, Se Young
    Guerin, Bastien
    Cho, Sanghee
    Reese, Timothy
    Zhu, Xuping
    Ouyang, Jinsong
    Catana, Ciprian
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [7] Simultaneous PET–MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET
    Charalampos Tsoumpas
    Jane E. Mackewn
    Philip Halsted
    Andrew P. King
    Christian Buerger
    John J. Totman
    Tobias Schaeffter
    Paul K. Marsden
    Annals of Nuclear Medicine, 2010, 24 : 745 - 750
  • [8] Clinical Impact of Respiratory Motion Correction in Simultaneous PET/MR, Using a Joint PET/MR Predictive Motion Model
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian F.
    Wan, Simon
    Fraioli, Francesco
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Atkinson, David
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (09) : 1467 - 1473
  • [9] Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR
    Kolbitsch, Christoph
    Ahlman, Mark A.
    Davies-Venn, Cynthia
    Evers, Robert
    Hansen, Michael
    Peressutti, Devis
    Marsden, Paul
    Kellman, Peter
    Bluemke, David A.
    Schaeffter, Tobias
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (05) : 846 - 852
  • [10] Respiratory Motion Detection and Correction for MR Using the Pilot Tone Applications for MR and Simultaneous PET/MR Examinations
    Vahle, Thomas
    Bacher, Mario
    Rigie, David
    Fenchel, Matthias
    Speier, Peter
    Bollenbeck, Jan
    Schaefers, Klaus P.
    Kiefer, Berthold
    Boada, Fernando E.
    INVESTIGATIVE RADIOLOGY, 2020, 55 (03) : 153 - 159