Report of a case receiving full-arch rehabilitation in both jaws using immediate implant loading protocols: A 1-year resonance frequency analysis follow-up

被引:11
|
作者
Portmann, M
Glauser, R
机构
[1] Univ Zurich, Dept Fixed Prosthodont & Dent Mat, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Dept Fixed Prosthodont & Dent Mat, Zurich, Switzerland
关键词
Branemark dental implants; immediate loading; primary stability; resonance frequency analysis; secondary stability;
D O I
10.2310/j.6480.2005.00027.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Immediate occlusal implant loading has been documented as a viable treatment option for various indications. However, documentations related to full-arch rehabilitation are usually limited to treatment of one jaw at a time, thereby leaving the opposing dentition unchanged. Furthermore, clinical documentation using traditional, well-accepted measuring techniques may not be adequate when it comes to short-term evaluation of the success or failure of implants subjected to immediate occlusal loading. Purpose: The purpose of this case report is to (1) present an implant stability follow-up of a patient receiving an immediate, implant-supported full-arch rehabilitation in both jaws and (2) evaluate the patient's acceptance of this rehabilitation. Materials and Methods: A 68-year-old patient scheduled for implant treatment was selected for an immediate implant loading protocol in both jaws. During two surgical events 3 weeks apart, eight maxillary and four mandibular Branemark System (R) Mk IV TiUnite(TM) fixtures (Nobel Biocare AB, Goteborg, Sweden) were inserted and subsequently used to immediately support a cross-arch fixed prosthesis in the maxilla and a bar-retained overdenture in the mandible. Implant stability was recorded from the day of surgery periodically during a 1-year follow-up using resonance frequency analysis (RFA). Results: At the 1-year follow-up, based on clinical, RFA, and radiographic evaluations, all implants and the reconstructions were classified as successful. All maxillary implants showed a decrease in the implant stability quotient (ISQ) value from the measurement at the time of surgery to the first follow-up, whereas two of four mandibular implants revealed an initial drop in stability. Irrespective of a specific ISQ level measured at implant surgery (ISQ range 53-74) and despite an initial decrease in stability, measurements recorded at the 12-month follow-up indicated similar stability levels for all maxillary implants (ISQ range 64-68) or the group of mandibular implants (ISQ range 72-75) but with a higher ISQ level for mandibular implants. Furthermore, the patient's acceptance of the immediate full-arch rehabilitation in both jaws was high. Conclusions: The present case report demonstrates that a slightly staged approach for full-arch rehabilitation in both jaws using immediate implant loading protocols is a realistic treatment option. Furthermore, RFA follow-up indicates that immediately occlusally loaded implants placed in reduced bone quality and quantity are more prone to loose stability in the early healing period compared with implants placed in dense bone quality.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 40 条
  • [1] Implant-supported full-arch rehabilitation with immediate loading using two different digital impression techniques: a case report with 2-year follow-up
    Garcia-Gil, Ignacio
    Brinkmann, Jorge Cortes-Breton
    Ferrero, Maria Martinez
    Sanchez-Monescillo, Andres
    Rico, Jesus Pelaez
    Suarez-Garcia, Maria Jesus
    [J]. QUINTESSENCE INTERNATIONAL, 2023, 54 (10): : 844 - 851
  • [2] Immediate postextraction implant placement with immediate loading for maxillary full-arch rehabilitation A two-year retrospective analysis
    Mozzati, Marco
    Arata, Valentina
    Gallesio, Giorgia
    Mussano, Federico
    Carossa, Stefano
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2012, 143 (02): : 124 - 133
  • [3] Implant-Supported PMMA Monolithic Full-Arch Rehabilitation with Surgical Computer-Planned Guide and Immediate Provisional: A Case Report with One Year Follow-Up
    Zizzari, Vincenzo Luca
    Tacconelli, Gianmarco
    [J]. CASE REPORTS IN DENTISTRY, 2018, 2018
  • [4] Long-term follow-up of full-arch immediate implant-supported restorations in edentulous jaws: a clinical study
    Werbelow, Laura
    Weiss, Michael
    Schramm, Alexander
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [5] Long-term follow-up of full-arch immediate implant-supported restorations in edentulous jaws: a clinical study
    Laura Werbelow
    Michael Weiss
    Alexander Schramm
    [J]. International Journal of Implant Dentistry, 6
  • [6] Immediate Versus Delayed Loading of Dental Implants Supporting Fixed Full-Arch Maxillary Prostheses: A 10-year Follow-up Report
    Pera, Paolo
    Menini, Maria
    Pesce, Paolo
    Bevilacqua, Marco
    Pera, Francesco
    Tealdo, Tiziano
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 27 - 31
  • [7] Full Digital Workflow for Prosthetic Full-Arch Immediate Loading Rehabilitation Using OT-Bridge System: A Case Report
    Piscopo, Marco
    Grande, Francesco
    Catapano, Santo
    [J]. PROSTHESIS, 2022, 4 (02): : 213 - 223
  • [8] Immediate Loading With LASER-Treated Surface Implant Two-Year Resonance Frequency Analysis Follow-up
    Duvina, Marco
    Barbato, Luigi
    Buti, Jacopo
    Delle Rose, Giovanna
    Brancato, Leila
    Casella, Giuseppe
    Longoni, Salvatore
    Sartori, Matteo
    Amunni, Franco
    Tonelli, Paolo
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) : 849 - 855
  • [9] Immediate Postextraction Screw-Retained Partial and Full-Arch Rehabilitation: A 3-Year Follow-up Retrospective Clinical Study
    Villa, Roberto
    Villa, Gabriele
    Del Fabbro, Massimo
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (05) : 627 - 636
  • [10] Implants Inserted with Low Insertion Torque Values for Intraoral Welded Full-Arch Prosthesis: 1-Year Follow-Up
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e39 - e40