Effect of Pre-Analytical Conditions on the Thrombodynamics Assay

被引:19
|
作者
Dashkevich, Natalia M. [1 ,2 ,3 ]
Vuimo, Tatiana A. [4 ]
Ovsepyan, Ruzanna A. [4 ]
Surov, Stepan S. [4 ]
Soshitova, Natalia P. [2 ]
Panteleev, Mikhail A. [2 ,3 ,5 ,6 ]
Ataullakhanov, Fazoil I. [2 ,3 ,4 ,5 ,6 ]
Negrier, Claude [1 ,7 ]
机构
[1] Univ Lyon 1, EA 4174, F-69365 Lyon, France
[2] HemaCore LLC, Moscow, Russia
[3] Ctr Theoret Problems Physicochem Pharmacol, Moscow, Russia
[4] Fed Res & Clin Ctr Pediat Hematol Oncol & Immunol, Moscow, Russia
[5] Natl Res Ctr Hematol, Moscow, Russia
[6] Moscow MV Lomonosov State Univ, Dept Phys, Moscow, Russia
[7] Hop Edouard Herriot, Unite Hemostase Clin, Lyon, France
基金
俄罗斯基础研究基金会;
关键词
Coagulation tests; thrombodynamics; pre-analytical variables; BLOOD COLLECTION TUBES; THROMBIN GENERATION; CLOT GROWTH; FACTOR-VII; COAGULATION; STANDARDIZATION; THROMBOPLASTIN; PROPAGATION; INITIATION; DYNAMICS;
D O I
10.1016/j.thromres.2013.12.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Standardization of pre-analytical conditions is the obligatory step for all potential diagnostic tests. Spatial clot growth (Thrombodynamics) is a new global hemostasis assay that considers spatial organization of coagulation. The principal parameter is rate of fibrin clot growth from the tissue-factor coated surface. In this work we studied the pre-analytical variables of Thrombodynamics assay that include conditions of blood collection, sample preparation and storage. Materials and Methods: Blood of apparently healthy volunteers was used. Eight types of citrate blood collection tubes were tested, centrifugation conditions for plasma preparation were evaluated and impact of plasma freezing/thawing was tested. Results: Among the blood collection tubes tested, BD Vacutainer glass tubes showed a significantly higher clot growth rate compared to plastic tubes. There was no difference between 3.2% and 3.8% of sodium citrate. For plasma preparation, a single 15 min centrifugation at 1 600 g shows significantly increased clot growth rate compared to plasma obtained by two sequential centrifugations (15 min 1 600 g, 5 min 10 000 g). There was no significant difference between 1 600 g and 2 100 g if the second centrifugation was performed. For the second centrifugation there was no difference between 20 min at 1 600 g and 5 min at 10 000 g. Frozen-thawed plasma showed increased clot growth rate compared to fresh plasma. Conclusion: The data represent the necessary steps for the standardization of Thrombodynamics assay and for the formulation of the operating guide. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:472 / 476
页数:5
相关论文
共 50 条
  • [41] PRE-ANALYTICAL ERRORS AND PATIENT SAFETY
    Plebani, Mario
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2012, 31 (04) : 265 - 270
  • [42] QUALITY INDICATORS OF THE PRE-ANALYTICAL PHASE
    Majkic-Singh, Nada
    Sumarac, Zorica
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2012, 31 (03) : 174 - 183
  • [43] Pre-analytical variables in miRNA analysis
    Becker, Nils
    Lockwood, Christina M.
    CLINICAL BIOCHEMISTRY, 2013, 46 (10-11) : 861 - 868
  • [44] Pre-analytical recommendations in clinical proteomics
    Lehmann, S.
    Ducoroy, P.
    Riviere, M.
    BULLETIN DU CANCER, 2008, 95 : S79 - S80
  • [45] Is a pre-analytical process for urinalysis required?
    Petit, Morgane
    Beaudeux, Jean-Louis
    Majoux, Sandrine
    Hennequin, Carole
    ANNALES DE BIOLOGIE CLINIQUE, 2017, 75 (05) : 519 - 524
  • [46] Pre-analytical variation of laboratory variables
    Watine, J
    Miédougé, M
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (03) : 263 - 263
  • [47] Blood gas pre-analytical considerations
    Mollard, JF
    ANNALES DE BIOLOGIE CLINIQUE, 2000, 58 (04) : 472 - 483
  • [48] Assessment of Pre-Analytical Sample Handling Conditions for Comprehensive Liquid Biopsy Analysis
    Gerber, Teresa
    Taschner-Mandl, Sabine
    Saloberger-Sindhoeringer, Lisa
    Popitsch, Niko
    Heitzer, Ellen
    Witt, Volker
    Geyeregger, Rene
    Hutter, Caroline
    Schwentner, Raphaela
    Ambros, Inge M.
    Ambros, Peter F.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2020, 22 (08): : 1070 - 1086
  • [49] Pre-analytical and analytical variability of reticulocyte counts in dogs
    Franchi, Roberta
    Giraldi, Marco
    Bertazzolo, Walter
    Bartolini, Francesca
    Di Maria, Francesca Maria
    Paltrinieri, Saverio
    VETERINARY RECORD, 2023, 192 (09) : no
  • [50] Harmonization of pre-analytical quality indicators
    Plebani, Mario
    Sciacovelli, Laura
    Aita, Ada
    Chiozza, Maria Laura
    BIOCHEMIA MEDICA, 2014, 24 (01) : 105 - 113