Prophylactic Ligature of AV Fistula Prevents High Output Heart Failure after Kidney Transplantation

被引:18
|
作者
Hetz, Patrick [1 ]
Pirklbauer, Markus [1 ]
Mueller, Silvana [2 ]
Posch, Lydia [3 ]
Gummerer, Maria [3 ]
Tiefenthaler, Martin [1 ]
机构
[1] Med Univ Innsbruck, Dept Internal Med 4, Nephrol & Hypertens, Anichstr 35, AT-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Internal Med 3, Cardiol & Angiol, Innsbruck, Austria
[3] Med Univ Innsbruck, Univ Hosp Vasc Surg, Dept Surg, Innsbruck, Austria
关键词
High-flow fistula; Fistula ligature; Heart failure; Kidney transplantation; ARTERIOVENOUS-FISTULA; PULMONARY-HYPERTENSION; HEMODIALYSIS-PATIENTS; CARDIAC-FUNCTION; DIALYSIS; ACCESS; CLOSURE;
D O I
10.1159/000508957
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background:Arteriovenous (AV) fistulas are considered the gold standard for ensuring safe and long-term vascular access in patients with haemodialysis-dependent end-stage renal disease. However, previous studies demonstrated that high-flow AV fistulas might add additional cardiovascular burden in the post-transplant setting, leading to frequent fistula closure in this population. Currently, there is no consensus regarding management of high-flow fistulas in post-transplant patients with stable kidney function. The present randomized controlled trial examines the effect of prophylactic AV fistula closure on high-output heart failure.Methods:Twenty-eight kidney transplant patients with stable graft function, absence of pre-existing severe cardiac failure, and brachial arterial flow rate of at least 1,500 mL/min were recruited and randomized in a 1:1 ratio to an intervention and control group, respectively. The intervention group was subject to immediate fistula ligature. Patients within the control group were referred to fistula ligature only if the main study endpoint high-output heart failure was reached. The latter was defined by the presence of at least 1 clinical sign (i.e., worsening NYHA score) and at least 2 of the following echocardiographic parameters: diameter of right atrium (major) >53 mm, right atrium (minor) >44 mm, inferior vena cava >= 21 mm, right pulmonary artery >20 mm, TAPSE <16 mm, systolic pulmonal artery pressure >40 mm Hg, and/or left ventricular eccentricity index <1. During a 24-month follow-up period, quarterly measurements of kidney function, NT-proBNP, and lactate dehydrogenase as well as a biannual echocardiographic check-up were performed.Results:High-output heart failure attributable to high-flow fistula was reported in 5 of 13 control patients (38.5%), whereas no patient in the intervention group presented with clinical and echocardiographic signs of high-output heart failure during the follow-up period. Thus, prophylactic ligature of high-flow fistulas avoided high-output heart failure in our patient population (p= 0.013). Three patients in the control group, however, had to undergo fistula ligature due to aneurysm formation (n= 2) and steal phenomenon (n= 1). Median NT-proBNP levels decreased from 317 ng/L pre-ligature to 223 ng/L post-ligature (p= 0.003). Serum creatinine levels did not significantly differ before and after AV fistula ligature (1.69 vs. 1.60 mg/dL, respectively,p= 0.059). Improvement of echocardiographic findings (e.g., a decrease in systolic pulmonary arterial pressure) was found in 7 of 8 ligature patients but did not reach statistical significance.Conclusion:Prophylactic ligature of high-flow AV fistulas after kidney transplantation can avoid high-output heart failure, and a more liberal approach to close AV fistulas might be justified.
引用
收藏
页码:511 / 519
页数:9
相关论文
共 50 条
  • [1] PROPHYLACTIC CLOSING OF AV FISTULA PREVENTS HIGH OUTPUT HEART FAILURE - A SINGLE-CENTER RANDOMISED CONTROLLED TRIAL
    Hetz, Patrick
    Mueller, Silvana
    Posch, Lydia
    Tiefenthaler, Martin
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1657 - 1657
  • [2] High Output Heart Failure Associated With Arteriovenous Fistula in the Setting of Kidney Transplantation
    Chang, Rachel S.
    Hu, Jiun-Ruey
    Beckman, Joshua A.
    Forbes, Rachel C.
    Shawar, Saed H.
    Concepcion, Beatrice P.
    KIDNEY INTERNATIONAL REPORTS, 2021, 6 (02): : 544 - 551
  • [3] Remote Stab Wound Resulting in AV Fistula and High-Output Heart Failure
    Rymer, Jennifer A.
    Anderson, Lindsay L.
    Posenau, J. Trevor
    Jones, W. Schuyler
    CASE REPORTS IN CARDIOLOGY, 2013, 2013
  • [4] A FORMIDABLE FISTULA: IMPROVED HIGH OUTPUT HEART FAILURE AFTER FISTULA CLOSURE
    Henstenburg, Brian
    Patel, Zeel J.
    George, Alvin J.
    Sheikh, Tarick
    Jacobs, Larry E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 2671 - 2671
  • [5] INCIDENCE OF AV FISTULA CLOSURE DUE TO HIGH OUTPUT CARDIAC FAILURE IN KIDNEY TRANSPLANTED PATIENTS
    Schier, Tabea
    Goebel, Georg
    Boesmueller, Claudia
    Gruber, Ingrid
    Tiefenthaler, Martin
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 260 - 260
  • [6] HIGH OUTPUT CARDIAC FAILURE DUE TO LARGE AV FISTULA
    Amberker, Deepa
    Khan, Talal
    Arif, Azka
    Ranganna, Karthik
    Doyle, Alden
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2014, 63 (05) : A25 - A25
  • [7] De novo heart failure after kidney transplantation in the presence of an arteriovenous fistula
    van Rhijn, Peter
    Stoumpos, Sokratis
    SCOTTISH MEDICAL JOURNAL, 2023, 68 (02) : NP36 - NP37
  • [8] AV Fistula Leading to High-Output Cardiac Failure in a Kidney Transplant Population: Our Experience
    Ahmad, Yahya R.
    Fattah, Hasan
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 648 - 649
  • [9] High output heart failure 8 months after an acquired arteriovenous fistula
    Durakoglugil, ME
    Kaya, MG
    Boyaci, B
    Cengel, A
    JAPANESE HEART JOURNAL, 2003, 44 (05): : 805 - 809
  • [10] Kidney Failure After Heart Transplantation
    Escoresca Ortega, A. M.
    de Azua Lopez, Z. Ruiz
    Hinojosa Perez, R.
    Ferrandiz Millon, C. M.
    Diaz Martin, A.
    Corcia Palomo, Y.
    Lage Galle, E.
    TRANSPLANTATION PROCEEDINGS, 2010, 42 (08) : 3193 - 3195