PET Image Reconstruction with Correction for Non-periodic Deformable Motion

被引:0
|
作者
Klyuzhin, Ivan S. [1 ]
Stortz, Greg [1 ]
Sossi, Vesna [1 ]
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
TRACKING; GATE; CT;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Image reconstruction techniques that use rectangular basis functions (pixels and voxels) may not be optimal when non-periodic, deformable motion correction is required. Here we propose a new approach to PET image reconstruction and non-rigid motion correction that is based on representing the imaged objects with regularized, spatially bounded sets of disconnected points. Motion correction is performed by explicitly incorporating the object motion into the reconstruction algorithm, though the dynamically adjusted coordinates of the points. Within the proposed approach, the images are reconstructed iteratively in list-mode, and the system matrix calculation is based on the localized estimation of the probabilistic weights for every point in the generated point set, using an optimized point search algorithm. To validate the motion correction, a digital phantom of a freely moving mouse was generated using mesh deformation operators such as armatures and curve modifiers. From the simulated PET list-mode data and a priori known motion trajectory, we reconstructed 3D images corrected for deformable, non-periodic motion without using the traditional gate-based methods. In addition, the stability of the reconstructed images with respect to the point set parameters and deformations was investigated.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] PET Image Reconstruction and Deformable Motion Correction Using Unorganized Point Clouds
    Klyuzhin, Ivan S.
    Sossi, Vesna
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (06) : 1263 - 1275
  • [2] Development of a Digital Unrestrained Mouse Phantom with Non-Periodic Deformable Motion
    Klyuzhin, Ivan S.
    Stortz, Greg
    Sossi, Vesna
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] ECG-Gated Interventional Cardiac Reconstruction for Non-periodic Motion
    Rohkohl, Christopher
    Lauritsch, Guenter
    Biller, Lisa
    Hornegger, Joachim
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT I, 2010, 6361 : 151 - +
  • [4] Motion compensation for PET image reconstruction using deformable tetrahedral meshes
    Manescu, P.
    Ladjal, H.
    Azencot, J.
    Beuve, M.
    Shariat, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (24): : 9269 - 9293
  • [5] Theoretical Comparison of Motion Correction Techniques for PET Image Reconstruction
    Asma, Evren
    Manjeshwar, Ravindra
    Thielemans, Kris
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1762 - 1767
  • [6] Optimal Quadrature Formulas for Non-periodic Functions in Sobolev Space and Its Application to CT Image Reconstruction
    Hayotov, A. R.
    Jeon, S.
    Lee, C. -O.
    Shadimetov, Kh. M.
    FILOMAT, 2021, 35 (12) : 4177 - 4195
  • [7] Respiratory Motion Correction in 4D-PET by Simultaneous Motion Estimation and Image Reconstruction (SMEIR)
    Kalantari, F.
    Li, T.
    Jin, M.
    Wang, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3661 - 3661
  • [8] Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR)
    Kalantari, Faraz
    Li, Tianfang
    Jin, Mingwu
    Wang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (15): : 5639 - 5661
  • [9] IMAGE-PROCESSING OF HRTEM IMAGES WITH NON-PERIODIC FEATURES
    DEJONG, AF
    COENE, W
    VANDYCK, D
    ULTRAMICROSCOPY, 1989, 27 (01) : 53 - 66
  • [10] PET Image Reconstruction and Motion Correction using Direct Backprojection on Point Grids and Clouds
    Klyuzhin, Ivan S.
    Dinelle, Katherine
    Sossi, Vesna
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4351 - 4356