Utility of Motor Evoked Potentials for Intraoperative Nerve Root Monitoring

被引:36
|
作者
MacDonald, David B. [1 ]
Stigsby, Bent [1 ]
Al Homoud, Iftetah [1 ]
Abalkhail, Tariq [1 ]
Mokeem, Amal [1 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Neurosci, Clin Neurophysiol Sect, Riyadh 11211, Saudi Arabia
关键词
Motor evoked potentials; Intraoperative monitoring; Nerve roots; TRANSCRANIAL ELECTRICAL-STIMULATION; SPINAL DEFORMITY SURGERY; MAGNETIC STIMULATION; LUMBOSACRAL RADICULOPATHY; NEUROPHYSIOLOGICAL DETECTION; DIAGNOSTIC UTILITY; SCOLIOSIS SURGERY; INJURY; CORD; MUSCLE;
D O I
10.1097/WNP.0b013e31824ceeaf
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
There is no entirely satisfactory way to monitor nerve root integrity during spinal surgery. In particular, standard free-running electromyography carries a high false-positive rate and some false-negative rate of injury. Stimulated electromyography to direct root stimulation can only be done intermittently, and roots are often inaccessible. This article reviews to what extent muscle motor evoked potential (MEP) monitoring might help. It presents background considerations, describes MEP methodology, and summarizes relevant experimental animal and clinical studies. Based on current evidence, root compromise can cause myotomal MEP deterioration that in some cases may be reversible. However, because of radicular overlap, limited sampling, confounding factors, and response variability, the effects range from no appreciable change to variable degrees of amplitude reduction to disappearance and some false-positive and false-negative results should be expected. For root monitoring, multichannel MEP recordings should span adjacent myotomes and avoid mixed myotome derivations. Only amplitude reduction warning criteria have been studied, but no percentage cutoff consensus has emerged, and this approach is troubled by response variability. There is some evidence that MEPs might reduce false electromyographic results. In conclusion, muscle MEPs could compliment electromyography but seem unlikely to completely solve the problem of nerve root monitoring.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 50 条
  • [1] A new criterion for detection of radiculopathy based on motor evoked potentials and intraoperative nerve root monitoring
    Traba, Alfredo
    Romero, Juan Pablo
    Arranz, Beatriz
    Vilela, Concepcion
    CLINICAL NEUROPHYSIOLOGY, 2018, 129 (10) : 2075 - 2082
  • [2] Intraoperative Monitoring of Facial Nerve Motor-Evoked Potentials in Children
    Bozinov, Oliver
    Grotzer, Michael A.
    Sarnthein, Johannes
    WORLD NEUROSURGERY, 2015, 84 (03) : 786 - 794
  • [3] Utility of Intraoperative Somatosensory and Motor Evoked Potentials in Detecting Cervical Root Avulsion
    Kesner, Vita G.
    Crum, Brian A.
    NEUROLOGY, 2009, 72 (11) : A129 - A129
  • [4] INTRAOPERATIVE MONITORING OF MOTOR EVOKED-POTENTIALS
    PEREON, Y
    BERNARD, JM
    ANESTHESIA AND ANALGESIA, 1994, 79 (06): : 1206 - 1206
  • [5] Facial nerve motor evoked potentials elicited by transcranial electrical stimulation for intraoperative monitoring
    Fukuda, Masafumi
    Oishi, Makoto
    Saito, Akihiko
    Takao, Tetsuro
    Fujii, Yukihiko
    NEUROLOGICAL SURGERY, 2008, 36 (04): : 315 - 321
  • [6] Intraoperative monitoring of pudendal nerve somatosensory evoked potentials
    Emerson, R
    Feldstein, N
    Adams, D
    Gallo, E
    Dowling, K
    NEUROLOGY, 1996, 46 (02) : 2050 - 2050
  • [7] Intraoperative motor evoked potentials monitoring in spinal neurosurgery
    Cioni, B
    Meglio, M
    Rossi, GF
    ARCHIVES ITALIENNES DE BIOLOGIE, 1999, 137 (2-3): : 115 - 126
  • [8] INTRAOPERATIVE MONITORING OF MOTOR FUNCTION BY MAGNETIC MOTOR EVOKED-POTENTIALS
    LEE, WY
    HOU, WY
    YANG, LH
    LIN, SM
    NEUROSURGERY, 1995, 36 (03) : 493 - 500
  • [9] Clinical Utility and Limitations of Intraoperative Monitoring of Visual Evoked Potentials
    Luo, Yeda
    Regli, Luca
    Bozinov, Oliver
    Sarnthein, Johannes
    PLOS ONE, 2015, 10 (03):
  • [10] Intraoperative motor evoked potentials
    Isley, MR
    Balzer, JR
    Pearlman, RC
    Zhang, XF
    AMERICAN JOURNAL OF ELECTRONEURODIAGNOSTIC TECHNOLOGY, 2001, 41 (04): : 266 - 338