Electrogenerated chemiluminescence reaction of lucigenin with isatin at a platinum electrode

被引:14
|
作者
Qi, HL [1 ]
Zhang, CX [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Xian 710062, Peoples R China
关键词
electrogenerated chemiluminescence; lucigenin; isatin; enhancement;
D O I
10.1002/bio.750
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrogenerated chemiluminescence (ECL) reaction of lucigenin with isatin was investigated at a platinum electrode in a neutral aqueous solution. The ECL intensity of lucigenin at -0.65 V was greatly enhanced by isatin, and the ECL intensity was about 50 times higher than that of lucigenin without isatin. The enhanced ECL was believed to be produced by the chemiluminescence reaction between reduced lucigenin and superoxide anion that was generated by the reaction of electrochemically reduced isatin with dissolved oxygen. The conditions for the determination of isatin were optimized. Under the optimized condition, the enhanced ECL intensity vs. isatin concentration was linear in the range 4.8 x 10(-7) - 1.9 x 10(-5) g/mL; with a detection limit of 3.3 x 10(-8) g/mL, and the relative standard derivation 1.0 x 10(-6) g/mL isatin was 3.8%. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 50 条
  • [1] Electrogenerated chemiluminescence of lucigenin at mesoporous platinum electrode and its biosensing application to superoxide dismutase
    Nam, Sungju
    Lee, Won-Yong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 808 : 59 - 64
  • [2] Electrogenerated chemiluminescence of Lucigenin in ethanol solution at a polycrystalline gold electrode
    Cui, Hua
    Zhang, Hao
    Shi, Ming-Juan
    Wang, Wei
    Dong, Yong-Ping
    Guo, Ji-Zhao
    ELECTROANALYSIS, 2007, 19 (16) : 1703 - 1710
  • [3] Highly Sensitive Determination of Riboflavin Based on the Enhanced Electrogenerated Chemiluminescence of Lucigenin at a Platinum Electrode in a Neutral Aqueous Solution
    Chengxiao Zhang
    Honglan Qi
    Analytical Sciences, 2002, 18 : 819 - 822
  • [4] Highly sensitive determination of riboflavin based on the enhanced electrogenerated chemiluminescence of lucigenin at a platinum electrode in a neutral aqueous solution
    Zhang, CX
    Qi, HL
    ANALYTICAL SCIENCES, 2002, 18 (07) : 819 - 822
  • [5] A new electrogenerated chemiluminescence peak of lucigenin in the hydrogen-evolution region induced by platinum nanoparticles
    Guo, Ji-Zhao
    Cui, Hua
    Xu, Sheng-Liang
    Dong, Yong-Ping
    JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (02): : 606 - 611
  • [6] Chemiluminescence of lucigenin by electrogenerated superoxide ions in aqueous solutions
    Okajima, T
    Ohsaka, T
    LUMINESCENCE, 2003, 18 (01) : 49 - 57
  • [7] The electrogenerated chemiluminescent behavior of hemin and its catalytic activity for the electrogenerated chemiluminescence of lucigenin
    Chen, GN
    Zhang, L
    Lin, RE
    Yang, ZC
    Duan, JP
    Chen, HQ
    Hibbert, DB
    TALANTA, 2000, 50 (06) : 1275 - 1281
  • [8] ELECTROGENERATED CHEMI-LUMINESCENCE OF LUCIGENIN IN AQUEOUS ALKALINE-SOLUTIONS AT A PLATINUM-ELECTRODE
    HAAPAKKA, KE
    KANKARE, JJ
    ANALYTICA CHIMICA ACTA, 1981, 130 (02) : 415 - 418
  • [9] Electrogenerated chemiluminescence of quantum dots with lucigenin as coreactant for sensitive detection of catechol
    Dong, YongPing
    Zhou, Ying
    Wang, Jiao
    Dong, YuQiong
    Wang, ChengMing
    TALANTA, 2016, 146 : 266 - 271
  • [10] Electrogenerated chemiluminescence of platinum octaethylporphyrin.
    Long, TR
    Richter, MM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U120 - U120