Radiographic feasibility study of cortical bone trajectory and traditional pedicle screw dual trajectories

被引:27
|
作者
Mullin, Jeffrey P. [1 ]
Perlmutter, Breanna [1 ]
Schmidt, Eric [1 ]
Benzel, Edward [1 ]
Steinmetz, Michael P. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Neurol Surg, 9500 Euclid Ave,Mail Code S100, Cleveland, OH 44195 USA
关键词
pedicle instrumentation; cortical bone trajectory; lumbar fusion; INSERTIONAL TORQUE; FIXATION STRENGTH; PLACEMENT;
D O I
10.3171/2016.4.SPINE151483
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE In 2009, Santoni and colleagues described a novel technique of posterior instrumentation; the cortical bone trajectory (CBT) was described as a caudocephalad and medial-to-lateral trajectory. Reported indications for CBT fixation include patients with osteoporosis, single-level degenerative disease, or adjacent-segment disease (ASD). In cases of revision surgery, it is technically possible and beneficial to place a traditional pedicle screw and a CBT screw at the same spinal level and side. It remains unclear as to the feasibility of placing both a traditional and a CBT screw at all levels of the lumbar spine and with varying trajectories of the preexisting traditional pedicle screws. Therefore, the authors conducted a study to radiographically assess the feasibility of using CBT and traditional pedicle screws at the same level in a large patient population. METHODS Using a 3D Spine Navigation WorkStation, the authors assessed 47 lumbar spine CT scans. These images were obtained from 2 disparate groups of patients: those who had previously undergone traditional pedicle instrumentation (prior surgery group) and those who had not (no prior surgery group). The authors virtually placed traditional pedicle and CBT screws at each lumbar level bilaterally. It was then determined if the dual trajectories were feasible, as defined by the presence or absence of a collision of the screw trajectories based on 3D imaging. RESULTS Overall, the authors evaluated 47 patients and were able to successfully plan dual trajectories in 50% of the pedicles. The no prior surgery group, compared with the prior surgery group, had a significantly greater success rate for dual trajectories. This difference was most significant in the lower lumbar levels (L3-5) where the prior instrumented group had success rates lower than 40% compared with the no prior surgery group's success rate, which was greater than 70%. There was a significant difference between each lumbar level in the lower spine. CONCLUSIONS There is a significant difference in the feasibility of planning CBT screws in patients who have undergone prior pedicle instrumentation compared with placing CBT and traditional pedicle screws simultaneously, but dual trajectory pedicle screws are a feasible option for posterior lumbar spinal instrumentation, especially as a de novo option in osteoporotic patients or in patients with ASD who underwent previous pedicle instrumentation. Ultimately, the practical clinical utility and biomechanical effects on the spine and instrumentation construct would require additional study.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [1] The Feasibility of Assessing the Cortical Bone Trajectory Screw Placement Accuracy Using a Traditional Pedicle Screw Insertion Evaluation System
    Ding, Hongtao
    Han, Bo
    Hai, Yong
    Liu, Yuzeng
    Guan, Li
    Pan, Aixing
    Liu, Tie
    CLINICAL SPINE SURGERY, 2021, 34 (02): : E112 - E120
  • [2] Controversies in Spine Surgery Is a Cortical Bone Trajectory Superior to Traditional Pedicle Screw Trajectory?
    Kolz, Joshua M.
    Pinter, Zachariah W.
    Bydon, Mohamad
    Sebastian, Arjun S.
    CLINICAL SPINE SURGERY, 2022, 35 (06): : 225 - 228
  • [3] Lumbar pedicle cortical bone trajectory screw
    Song Tengfei
    Hsu, Wellington K.
    Ye Tianwen
    CHINESE MEDICAL JOURNAL, 2014, 127 (21) : 3808 - 3813
  • [4] Lumbar pedicle cortical bone trajectory screw
    Song Tengfei
    Wellington K Hsu
    Ye Tianwen
    中华医学杂志(英文版), 2014, (21) : 3808 - 3813
  • [5] Biomechanical comparative study of midline cortical vs. traditional pedicle screw trajectory in osteoporotic bone
    Stefan Schleifenbaum
    Ann-Cathrin Vogl
    Robin Heilmann
    Nicolas Heinz von der Hoeh
    Christoph-Eckhard Heyde
    Jan-Sven Jarvers
    BMC Musculoskeletal Disorders, 24
  • [6] Biomechanical comparative study of midline cortical vs. traditional pedicle screw trajectory in osteoporotic bone
    Schleifenbaum, Stefan
    Vogl, Ann-Cathrin
    Heilmann, Robin
    von der Hoeh, Nicolas Heinz
    Heyde, Christoph-Eckhard
    Jarvers, Jan-Sven
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [7] Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw
    Akpolat, Yusuf Tahiri
    Inceoglu, Serkan
    Kinne, Nolan
    Hunt, Devon
    Cheng, Wayne K.
    SPINE, 2016, 41 (06) : E335 - E341
  • [8] Comparison of the clinical and radiographic outcomes of cortical bone trajectory and traditional trajectory pedicle screw fixation in transforaminal lumbar interbody fusion: a randomized controlled trial
    Chenyu Wu
    Xinli Hu
    Rongjie Liu
    Cong Xu
    Yi Jiang
    Zhaohui Ge
    Kailiang Zhou
    Di Zhang
    Aimin Wu
    Haicheng Dou
    Hui Xu
    Naifeng Tian
    Zhichao Hu
    Wenfei Ni
    European Spine Journal, 2024, 33 : 1069 - 1080
  • [9] Comparison of the clinical and radiographic outcomes of cortical bone trajectory and traditional trajectory pedicle screw fixation in transforaminal lumbar interbody fusion: a randomized controlled trial
    Wu, Chenyu
    Hu, Xinli
    Liu, Rongjie
    Xu, Cong
    Jiang, Yi
    Ge, Zhaohui
    Zhou, Kailiang
    Zhang, Di
    Wu, Aimin
    Dou, Haicheng
    Xu, Hui
    Tian, Naifeng
    Hu, Zhichao
    Ni, Wenfei
    EUROPEAN SPINE JOURNAL, 2024, 33 (03) : 1069 - 1080
  • [10] Biomechanical Evaluation of Cross Trajectory Technique for Pedicle Screw Insertion: Combined Use of Traditional Trajectory and Cortical Bone Trajectory
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Asazuma, Takashi
    Nemoto, Koichi
    ORTHOPAEDIC SURGERY, 2015, 7 (04) : 317 - 323