Tear Film Images and Breakup Analyzed Using Fluorescent Quenching

被引:39
|
作者
King-Smith, P. Ewen [1 ]
Ramamoorthy, Padmapriya [1 ]
Braun, Richard J. [2 ]
Nichols, Jason J. [3 ]
机构
[1] Ohio State Univ, Coll Optometry, Columbus, OH 43210 USA
[2] Univ Delaware, Dept Math Sci, Newark, DE 19716 USA
[3] Univ Houston, Coll Optometry, Houston, TX USA
基金
美国国家科学基金会;
关键词
breakup; fluorescence; quenching; evaporation; tangential flow; LIPID LAYER; REPEATABILITY; EVAPORATION; PRECORNEAL; CORNEAL; INSTABILITY; VALUES; TIME;
D O I
10.1167/iovs.13-12628
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Tear evaporation should increase fluorescein concentration, causing fluorescence dimming from self-quenching for high but not low fluorescein concentration. This prediction was tested and compared to the predicted effect of "tangential flow'' that fluorescence dimming should be similar for high and low concentrations. METHODS. A custom optical system was used for video recording of tear film fluorescence in 30 subjects. The subjects were asked to blink at the start of the recording and try to keep their eyes open for the rest of the 60-second recording. An initial recording was made after instillation of 1 mu L 0.1% fluorescein followed by further recordings at 5-minute intervals using 0.5% and 5% fluorescein. RESULTS. Decay of fluorescence was considerably greater for the high (5%) concentration condition than for the low (0.1%) concentration. This is shown by "ratio images'' (ratio of the intensity of a fluorescence image at a later time divided by that of an earlier image), fluorescence decay curves, fluorescence decay rates, and histograms of estimated tear thickness decrease. For example, for the high concentration condition, decay rates were higher than for the low concentration for all 30 subjects (P < 0.0001, binomial test). Additionally, breakup time was significantly reduced for the high compared to the low concentration condition. CONCLUSIONS. The greater fluorescence decay and more rapid breakup for the high concentration condition are the results expected if thinning and breakup are mainly due to evaporation, hence causing self-quenching. Fluorescence decay rate for the low concentration condition was not significantly greater than zero.
引用
收藏
页码:6003 / 6011
页数:9
相关论文
共 50 条
  • [1] Tear film breakup and dynamics analyzed and displayed with pseudo-color images
    King-Smith, Peter Ewen
    Begley, Carolyn G.
    Braun, Richard J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [2] Tear Film Breakup and Structure Studied by Simultaneous Video Recording of Fluorescence and Tear Film Lipid Layer Images
    King-Smith, P. Ewen
    Reuter, Kathleen S.
    Braun, Richard J.
    Nichols, Jason J.
    Nichols, Kelly K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) : 4900 - 4909
  • [3] INTERPRETATION OF TEAR FILM BREAKUP
    VANLEY, GT
    LEOPOLD, IH
    GREGG, TH
    ARCHIVES OF OPHTHALMOLOGY, 1977, 95 (03) : 445 - 448
  • [4] Tear breakup dynamics: A technique for quantifying tear film instability
    Begley, CG
    Himebaugh, N
    Renner, D
    Liu, HX
    Chalmers, R
    Simpson, T
    Varikooty, J
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (01) : 15 - 21
  • [5] Mechanisms, imaging and structure of tear film breakup
    King-Smith, P. Ewen
    Begley, Carolyn G.
    Braun, Richard J.
    OCULAR SURFACE, 2018, 16 (01): : 4 - 30
  • [6] Parameter Estimation for Tear Film Breakup Dynamics
    Luke, Rayanne A.
    Braun, Richard J.
    Driscoll, Tobin A.
    Antwi, Deborah
    Begley, Carolyn G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [7] On tear film breakup (TBU): dynamics and imaging
    Braun, Richard J.
    Driscoll, Tobin. A.
    Begley, Carolyn G.
    King-Smith, P. Ewen
    Siddique, Javed I.
    MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA, 2018, 35 (02): : 145 - 180
  • [8] Tear Film Breakup Time in Diabetic Patients
    Zaman, Saliha
    Samuel, Eileen
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (07): : 774 - 774
  • [9] Evaporation is not the only mechanism of tear film breakup
    King-Smith, Peter Ewen
    Ramamoorthy, Padmapriya
    Begley, Carolyn G.
    Braun, Richard J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] Non-invasive and objective tear film breakup detection on interference color images using convolutional neural networks
    Kikukawa, Yasushi
    Tanaka, Shin
    Kosugi, Takuya
    Pflugfelder, Stephen C.
    PLOS ONE, 2023, 18 (03):