Geometric and dosimetric variations of ICRU bladder and rectum reference points in vaginal cuff brachytherapy using ovoids

被引:9
|
作者
Garipagaoglu, M [1 ]
Tuncel, N
Köseoglu, FG
Gülkesen, H
Kizildag, AÜ
Toy, A
Dalmaz, MG
机构
[1] Akdeniz Univ Hosp, Dept Radiat Oncol, Sch Med, TR-07059 Antalya, Turkey
[2] Akdeniz Univ Hosp, Sch Med, Dept Biostat, Antalya, Turkey
关键词
D O I
10.1016/j.ijrobp.2003.11.039
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the interfractional geometric and dose variations of rectal reference point (R) and bladder reference point (BL) doses in patients receiving vaginal cuff irradiation using high-dose-rate brachytherapy with 2 ovoids and the change in calculated radiobiologic-equivalent dose of R and BL. Methods: ICRU-38 R and BL reference doses were calculated. The variation in positions of ovoids, R, and BL were determined. Whether the magnitude of displacement shows a time trend and has an effect on calculated R and BL doses was evaluated. The relation between the ovoid diameter and both the magnitude of displacement and changes in R and BL doses was studied. Changes in radiobiologic-equivalent dose of rectum and bladder were determined. Results: The average magnitude of displacements was 3.2 and 12.1 mm, showed no time trend, and no tendency to displacement in a certain direction. Mean changes in BL and R doses were 64-75 cGy and 47-58 cGy, respectively. There was a relation between neither ovoid size and displacement nor R and BL dose change. Dose and geometric variation showed no correlation (p > 0.05). The differences in radiobiologic-equivalent dose of R and B were not significant. Conclusion: Although there were significant differences in R and B position and doses among the fractions, the magnitudes of dose changes were relatively small, and total calculated radiobiologic-equivalent doses of R and B did not change significantly. According to the results of this study, the benefit of treatment planning is limited to supporting treatment planning in each fraction. (C) 2004 Elsevier Inc.
引用
收藏
页码:1607 / 1615
页数:9
相关论文
共 29 条
  • [1] The contribution of optimization in vaginal cuff brachytherapy using ovoids, normalized to catheter oriented dose points
    Tuncel, N
    Garipagaoglu, M
    Kizildag, AU
    Koseoglu, FG
    Toy, A
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S21 - S22
  • [2] ICRU REFERENCE POINTS AND MAXIMUM DOSES OF RECTUM AND BLADDER IN INTRACAVITARY RADIOTHERAPY
    LAHTINEN, T
    TENHUNEN, M
    VAYRYNEN, M
    RADIOTHERAPY AND ONCOLOGY, 1993, 28 (02) : 174 - 176
  • [3] VOLUMETRIC D2CC DOSE COMPARED TO ICRU REFERENCE POINT DOSE TO BLADDER IN VAGINAL CUFF BRACHYTHERAPY
    Palmgren, J. E.
    Lahtinen, T.
    Anttila, M.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S226 - S227
  • [4] Interfraction Geometric and Dosimetric Variations in Vaginal Cuff High Dose-rate Brachytherapy using CT Based Planning: A Prospective Study
    Bellon, M.
    Fraser, C.
    Sintay, B.
    Chetty, I.
    Elshaikh, M. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S381 - S382
  • [5] Planning study using various applicators for vaginal cuff brachytherapy; Three ovoids technique
    Lee, Y.
    Kim, S.
    Choi, H. J.
    Kim, H.
    Yoon, H.
    Son, T.
    Kim, M. S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1920 - S1921
  • [6] Dosimetric comparison of bladder, rectal, and vaginal surface doses between ovoids and cylinder-based vaginal brachytherapy in carcinoma of the endometrium
    Kumar, Naveen Pradeep
    Kumar, Aswin
    Jayaprakash, Puthuveettil G.
    Raghukumar, P.
    James, Francis V.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (06) : 1191 - 1195
  • [7] Dosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapy
    Jamema, Swamidas V.
    Saju, Sherly
    Mahantshetty, Umesh
    Pallad, S.
    Deshpande, D. D.
    Shrivastava, S. K.
    Dinshaw, K. A.
    JOURNAL OF MEDICAL PHYSICS, 2008, 33 (01) : 3 - 8
  • [8] INTER FRACTION VARIATIONS IN RECTUM AND BLADDER DOSES FOR HIGH-DOSE-RATE VAGINAL CUFF BRACHYTHERAPY EVALUATED BY REPETITIVE CT-EXAMINATIONS
    Sabater Marti, S.
    Berenguer, R.
    Aguayo Martos, M.
    Sevillano Capellan, M.
    Rivera, M.
    Vilar, S.
    Nunez, A. T.
    Villas, M. V.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S138 - S139
  • [9] Rectum and bladder doses defined from CT-assisted planning in PDR brachytherapy: comparison with ICRU reference doses
    Barillot, I
    Peignaux, K
    Truc, G
    Brenier, J
    Maingon, P
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S236 - S237
  • [10] Dosimetric Evaluations of the Bladder and Rectum in Brachytherapy Treatments Using Multi-Lumen Cylinders
    Dumitru, N.
    Shojaei, M.
    Pella, S.
    Leventouri, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E246 - E246