Optimization of Receptor Occupancy Assays in Mass Cytometry: Standardization Across Channels with QSC Beads
被引:6
|作者:
Bringeland, Gerd Haga
[1
,2
]
Bader, Lucius
[3
,4
]
Blaser, Nello
[5
]
Budzinski, Lisa
[6
]
Schulz, Axel R.
[6
]
Mei, Henrik E.
[6
]
Myhr, Kjell-Morten
[1
,2
]
Vedeler, Christian A.
[1
,2
]
Gavasso, Sonia
[1
,2
]
机构:
[1] Haukeland Hosp, Dept Neurol, Jonas Lies Vei 65, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Med, Bergen, Norway
[3] Haukeland Hosp, Bergen Grp Epidemiol & Biomarkers Rheumat Dis, Dept Rheumatol, Bergen, Norway
[4] Univ Bergen, Dept Clin Sci, Bergen, Norway
[5] Univ Bergen, Dept Math, Bergen, Norway
[6] German Rheumatism Res Ctr Berlin DRFZ, Berlin, Germany
关键词:
receptor occupancy;
biomarkers;
QSC beads;
CyTOF;
standardization;
optimization;
multiple sclerosis;
natalizumab;
quantitative analysis;
mass cytometry;
FLOW-CYTOMETRY;
D O I:
10.1002/cyto.a.23723
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Receptor occupancy, the ratio between amount of drug bound and amount of total receptor on single cells, is a biomarker for treatment response to therapeutic monoclonal antibodies. Receptor occupancy is traditionally measured by flow cytometry. However, spectral overlap in flow cytometry limits the number of markers that can be measured simultaneously. This restricts receptor occupancy assays to the analysis of major cell types, although rare cell populations are of potential therapeutic relevance. We therefore developed a receptor occupancy assay suitable for mass cytometry. Measuring more markers than currently available in flow cytometry allows simultaneous receptor occupancy assessment and high-parameter immune phenotyping in whole blood, which should yield new insights into disease activity and therapeutic effects. However, varying sensitivity across the mass cytometer detection range may lead to misinterpretation of the receptor occupancy when drug and receptor are detected in different channels. In this report, we describe a method for optimization of mass cytometry receptor occupancy measurements by using antibody-binding quantum simply cellular (QSC) beads for standardization across channels with different sensitivities. We evaluated the method in a mass cytometry-based receptor occupancy assay for natalizumab, a therapeutic antibody used in multiple sclerosis treatment that binds to alpha 4-integrin, which is expressed on leukocyte cell surfaces. Peripheral blood leukocytes from a treated patient were stained with a panel containing metal-conjugated antibodies for detection of natalizumab and alpha 4-integrin. QSC beads with known antibody binding capacity were stained with the same metal-conjugated antibodies and were used to standardize the signal intensity in the leukocyte sample before calculating receptor occupancy. We found that QSC bead standardization across channels corrected for sensitivity differences for detection of drug and receptor and generated more accurate results than observed without standardization. (c) 2019 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.