An analytical fit and EGSnrc code (MC) calculations of personal dose equivalent conversion coefficients for mono-energetic electrons

被引:7
|
作者
Al Kanti, Hassan [1 ]
El Hajjaji, O. [1 ]
El Bardouni, T. [1 ]
Mohammed, Maged [2 ]
机构
[1] Abdelmalek Essaadi Univ, Fac Sci, Radiat & Nucl Syst Lab, Tetouan, Morocco
[2] Ibn Tofail Univ, Fac Sci, SIMO LAB, Kenitra, Morocco
关键词
Conversion coefficients; Personal dose equivalent; Electron; EGSnrc; CYLINDER PHANTOM; ENERGY;
D O I
10.1016/j.apradiso.2019.108906
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This study aims for calculating a new set of the personal dose equivalent conversion coefficients H-p(d)/phi when d = 0.07, 3, and 10 mm, for mono-energetic electron beams ranged from 0.06 MeV to 50 MeV for H-p(0.07), from 0.7 MeV to 50 MeV for H-p(3) and from 2 MeV to 50 MeV for H-p(10), which has incident on ICRU slab phantom. Additionally, we have calculated the conversion coefficients of a dose to the lens eye of into a new cylindrical phantom of the ORAMED project. The cylindrical phantom was proposed for calculating the eye lens dose equivalent as a cylinder much better approximates the form of a head than a slab. The ICRU tissue of density of 1 g/cm(3) which is consists of 4-elemental has been used in slab and cylindrical phantoms. The calculations were carried out with EGSnrc code Monte Carlo (MC) and a new an analytical fit is applied to the data. Our results are found in a good agreement with those published by Veinot and Hertel (2012)), with a local difference less than 1.5%. We have concluded that new analytical fits provide a convenient approach for determining conversion coefficients for discrete incident such as MC.
引用
收藏
页数:7
相关论文
共 5 条
  • [1] Personal Dose Equivalent Conversion Coefficients Skins Dose for Mono-Energetic Photons, Electrons, and Positrons: Monte Carlo Approach and Development of an Analytical Approach
    Al Kanti, Hassan
    El Hajjaji, O.
    El Bardouni, T.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2019, 74 (05) : 520 - 528
  • [2] Personal Dose Equivalent Conversion Coefficients Skins Dose for Mono-Energetic Photons, Electrons, and Positrons: Monte Carlo Approach and Development of an Analytical Approach
    Hassan Al Kanti
    O. El Hajjaji
    T. El Bardouni
    Moscow University Physics Bulletin, 2019, 74 : 520 - 528
  • [3] Personal dose equivalent conversion coefficients for electrons to 1 Ge V
    Veinot, K. G.
    Hertel, N. E.
    RADIATION PROTECTION DOSIMETRY, 2012, 149 (03) : 347 - 352
  • [4] Conversion coefficients calculation of mono-energetic photons from air-kerma using Monte Carlo and analytical methods
    Al Kanti, Hassan
    El Hajjaji, O.
    El Bardouni, T.
    Boukhal, H.
    Mohammed, Maged
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2020, 32 (01) : 288 - 293
  • [5] Conversion coefficients from fluence and air kerma to personal dose equivalent for monoenergetic photons using analytical fit and Monte Carlo simulation
    Al Kanti, Hassan
    El Hajjaji, O.
    El Bardouni, T.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (01): : 31 - 44