An experimental study on the identification of delamination in a composite material by the passive electric potential CT method

被引:7
|
作者
Nakatani, K.
Kubo, S.
Sakagami, T.
Shiozawa, D.
Takagi, M.
机构
[1] Osaka Univ, Grad Sch Engn, Dept Mech & Syst Engn, Suita, Osaka 5650871, Japan
[2] Konan Univ, Dept Mech Engn, Nada Ku, Kobe, Hyogo 6588501, Japan
关键词
piezoelectric materials; PVDF; delamination identification; non-destructive evaluation; inverse analysis;
D O I
10.1088/0957-0233/18/1/006
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
When a piezoelectric film is glued on the surface of a structure member subjected to mechanical load, a distribution of electric potential is induced. In the existence of defects in the member, a characteristic variation of electric potential is observed. Based on this phenomenon, the passive electric potential CT (computed tomography) method is developed for detecting and identifying defects in a structure. In this study, the applicability of the passive electric potential CT method to the identification of a delamination in a CFRP laminate was experimentally examined. CFRP laminate specimens, which have an artificial interlaminer delamination, with a piezoelectric film on their surface were subjected to three-point bending. The electric potential distribution on the piezoelectric film was measured by a non-contact voltmeter. Characteristic variation reflecting the location and the size of the delamination is observed in the measured electric potential distributions. To identify the delamination, an inverse method was constructed based on the least-squares residual evaluated between the measured and computed electric potential distributions. The location and size of the delamination were estimated accurately. It was shown that the passive electric potential CT method using a piezoelectric film was useful for the quantitative identification of interlaminar delamination in laminated composite materials.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [1] Identification of delamination in layered composite materials by the electric potential CT method
    Kubo, Shiro
    Kuchinishi, Manabu
    Sakagami, Takahide
    Ioka, Seiji
    International Journal of Applied Electromagnetics and Mechanics, 2001, 15 (1-4 SPEC) : 261 - 267
  • [2] Identification of delamination in layered composite materials by the electric potential CT method
    Kubo, S
    Kuchinishi, M
    Sakagami, T
    Ioka, S
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2001, 15 (1-4) : 261 - 267
  • [3] An experimental study on applicability of passive electric potential CT method to crack identification
    Shiozawa, D
    Kubo, S
    Sakagami, T
    JSME INTERNATIONAL JOURNAL SERIES A-SOLID MECHANICS AND MATERIAL ENGINEERING, 2004, 47 (03) : 419 - 425
  • [4] Passive electric potential CT method using piezoelectric material for crack identification
    Shiozawa, D
    Kubo, S
    Sakagami, T
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2004, 12 (01) : 71 - 79
  • [5] Passive electric potential CT method using piezoelectric material for identification of plural cracks
    Shiozawa, D
    Kubo, S
    Sakagami, T
    Takagi, M
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2006, 11 (01): : 27 - 36
  • [6] Passive electric potential CT method using piezoelectric material for identification of plural cracks
    Department of Mechanical Engineering, Kobe University, 1-1, Rokkodai, Nada, Kobe 657-8501, Japan
    不详
    CMES Comput. Model. Eng. Sci., 2006, 1 (27-36):
  • [7] An experimental study on applicability of passive electric potential CT method to identification of three-dimensional surface crack
    Shiozawa, Daiki
    Kubo, Shiro
    Sakagami, Takahide
    Nihon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2005, 71 (07): : 1038 - 1045
  • [8] Experimental study on applicability of passive electric potential CT method for identification of three-dimensional surface crack
    Shiozawa, Daiki
    Kubo, Shiro
    Sakagami, Takahide
    JSME INTERNATIONAL JOURNAL SERIES A-SOLID MECHANICS AND MATERIAL ENGINEERING, 2006, 49 (03) : 426 - 435
  • [9] Passive electric potential CT method using piezoelectric film for identification of defects
    Kubo, Shiro
    Sakagami, Takahide
    Ioka, Seiji
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2013, 21 (06) : 917 - 928
  • [10] Detection of delamination in graphite/epoxy composite by electric potential method
    Chu, YW
    Yum, YJ
    KORUS 2001: 5TH KOREA-RUSSIA INTERNATIONAL SYMPOSIUM ON SCIENCE AND TECHNOLOGY, VOL 3, PROCEEDINGS, 2001, : 15 - 17