How does scanner choice and 3D model resolution affect data accuracy?

被引:10
|
作者
Balolia, Katharine L. [1 ]
Massey, Jason S. [2 ,3 ]
机构
[1] Australian Natl Univ, Sch Archaeol & Anthropol, Canberra, ACT, Australia
[2] Univ Minnesota, Sch Med, Dept Integrat Biol & Physiol, Minneapolis, MN 55455 USA
[3] Monash Univ, Dept Anat & Dev Biol, Melbourne, Vic, Australia
关键词
Accuracy; CT scanning; laser scanning; resolution; virtual measurements; white light scanning;
D O I
10.1111/joa.13343
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Researchers using digital methods often collect data from 3D models at different resolutions, obtained using different scanning techniques. Although previous research has sought to understand whether scanning method and model resolution affect data accuracy, no study has systematically evaluated the sources of error associated with scanning method, data acquisition method and model resolution with the aim of providing practical recommendations about the model resolution required to yield sufficiently accurate data for specimens of given sizes. In this study, using data taken from primate specimens of three broad size categories, we test whether 3D models obtained using five different scanners (Breuckmann SmartSCAN, DAVID/HP 3D Pro S3, NextEngine 2020i, Creaform Go!Scan 20 and microCT/clinicalCT) yield accurate measurements. We assess whether caliper measurements can be used alongside measurements collected from 3D surface models, whether scanning resolution affects measurement accuracy, and how scan resolution, estimated using each scanner's proprietary software, compares to model resolution measured in a standardized way. Each scanner produces 3D models that yield accurate measurements for each size category, however, combining caliper data with those taken from digital models can be problematic. Our results indicate that the accuracy of measurements taken from 3D models depends on both object size and model resolution. Based on our findings, we recommend that small specimens should be scanned at <0.3 mm, medium specimens at 0.3-0.7 mm, and large specimens at 0.3-0.5 mm resolutions if data taken from 3D surface models are to be combined with caliper datasets. We further show, for the first time, that discrepancies in estimated final model resolution are frequently observed across software packages. We therefore recommend that researchers ensure that final model resolutions are adequate based on specimen size and are independently verified using a software package other than the scanner's proprietary software. Finally, we consider the implications of the findings that measurements obtained from surface models are variably consistent with those obtained using calipers.
引用
收藏
页码:679 / 692
页数:14
相关论文
共 50 条
  • [1] Accuracy Comparison of the Optical 3D Scanner and CT Scanner
    Mendricky, Radomir
    Sobotka, Jiri
    MANUFACTURING TECHNOLOGY, 2020, 20 (06): : 791 - 801
  • [2] Does Valuation Model Choice Affect Target Price Accuracy?
    Demirakos, Efthimios G.
    Strong, Norman C.
    Walker, Martin
    EUROPEAN ACCOUNTING REVIEW, 2010, 19 (01) : 35 - 72
  • [3] 3D SUPER-RESOLUTION APPROACH FOR SPARSE LASER SCANNER DATA
    Hosseinyalamdary, S.
    Yilmaz, A.
    ISPRS GEOSPATIAL WEEK 2015, 2015, II-3 (W5): : 151 - 157
  • [4] Accuracy Improvement Method of a 3D Laser Scanner Based on the D-H Model
    Chen, Kai
    Zhan, Kai
    Yang, Xiaocong
    Zhang, Da
    SHOCK AND VIBRATION, 2021, 2021
  • [5] How Does the Choice of Distributed Meteorological Data Affect Hydrologic Model Calibration and Streamflow Simulations?
    Elsner, Marketa M.
    Gangopadhyay, Subhrendu
    Pruitt, Tom
    Brekke, Levi D.
    Mizukami, Naoki
    Clark, Martyn P.
    JOURNAL OF HYDROMETEOROLOGY, 2014, 15 (04) : 1384 - 1403
  • [6] How does choice affect evaluations?
    Brown, C
    Feinberg, F
    ADVANCES IN CONSUMER RESEARCH, VOLUME XXIX, 2002, 29 : 331 - 332
  • [7] On The Effectiveness and Accuracy of .Decimal's 3D Scanner System
    Newton, J.
    Li, K.
    John, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E504 - E505
  • [8] INFLUENCE OF CT SCANNER CHARACTERISTICS ON 3D RECONSTRUCTION ACCURACY
    DORE, S
    KEARNEY, RE
    DEGUISE, J
    CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY CONFERENCE : PROCEEDINGS - 1989, 1989, : 25 - 26
  • [9] 3D Data Processing for Enhancement of Face Scanner Data
    Bozkurt, Nesli
    Halici, Ugur
    Ulusoy, Ilkay
    Akagunduz, Erdem
    2009 IEEE 17TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, VOLS 1 AND 2, 2009, : 690 - 693
  • [10] ROS BASED ADJUSTABLE RESOLUTION COMPACT 3D SCANNER
    Dion, Scott
    Tatoglu, Akin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 4, 2020,