Research on Sensors Arrangement for Capsule Endoscope Microrobot Magnetic Localization

被引:0
|
作者
Xu, Jiansheng [1 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing 100080, Peoples R China
关键词
Capsule Endoscope Microrobot; Magnetic Localization; Optimal;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The position and attitude of a capsule endoscope microrobot are essential for its application, but there are few methods to evaluate them without nuclear radiation. Magnetic localization is one of most feasible methods. It is obvious that the magnetic sensors arrangement directly influence the accuracy of the position and attitude So, I do some work on optimizing the sensors arrangement using 3D magnetic sensors from simulation. It is supposed that a cylindrical permanent magnet is embedded into the capsule microrobot. The typical arrangement simulation results show that the best accuracy of position and attitude can be obtained using the sensor data of the eight vertexes of the cubic of motion space.
引用
收藏
页码:5208 / 5211
页数:4
相关论文
共 50 条
  • [1] On localizing a Capsule Endoscope using Magnetic Sensors
    Moussakhani, Babak
    Ramstad, Tor
    Flam, John T.
    Balasingham, Ilangko
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4058 - 4062
  • [2] Inchworm-like microrobot for capsule endoscope
    Kim, B
    Lee, S
    Park, JH
    Park, JO
    IEEE ROBIO 2004: PROCEEDINGS OF THE IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, 2004, : 458 - 463
  • [3] Dipole modeling of magnetic marker for capsule endoscope localization
    Wang, Xiaona
    Meng, Max Q. -H.
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 5382 - +
  • [4] Detection of Weak Magnetic Signal for Magnetic Localization and Orientation in Capsule Endoscope
    Li, Mao
    Hu, Chao
    Song, Shuang
    Dai, Houde
    Meng, Max Q. -H.
    2009 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS ( ICAL 2009), VOLS 1-3, 2009, : 900 - +
  • [5] The software implementation of magnetic localization and orientation detection for capsule endoscope
    Ma, Tongxing
    Hu, Chao
    Meng, Max Q. -H.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 35 - 38
  • [6] Design of a Reconfigurable Sensor Array for Localization of Magnetic Capsule Endoscope
    Liu, Hongxi
    Su, Jingran
    Song, Shuang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [7] An Improved Magnetic Localization and Orientation Algorithm for Wireless Capsule Endoscope
    Hu, Chao
    Yang, Wanan
    Chen, Dongmei
    Meng, Max Q. -H.
    Dai, Houde
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2055 - 2058
  • [8] Magnetic Localization Method of Capsule Endoscope Based on Hybrid Model
    Zhang, Qi
    Li, Yuming
    Xu, Han
    Li, Xiao
    Zhang, Xiwei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [9] Localization Method for a Magnetic Capsule Endoscope Propelled by a Rotating Magnetic Dipole Field
    Popek, Katie M.
    Mahoney, Arthur W.
    Abbott, Jake J.
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 5348 - 5353
  • [10] Magnetic localization and orientation of the capsule endoscope based on a random complex algorithm
    He, Xiaoqi
    Zheng, Zizhao
    Hu, Chao
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2015, 8 : 175 - 184