Corrosion rate of steel in concrete - From laboratory to reinforced structures

被引:4
|
作者
Elsener, B
机构
关键词
corrosion rate; polarization resistance; localized corrosion; current distribution; macrocell; galvanostatic pulse; monitoring;
D O I
10.4028/www.scientific.net/MSF.247.127
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Measuring corrosion rate of rebars in reinforced concrete is essential for establishing service life prediction of structures and controlling the efficiancy of repair methods. Different electrochemical techniques, all based on measuring the polarization resistance, are used in the laboratory and on site, In calculating corrosion rate from the experimentally determined Rp value, two main problems arise: current distribution between the small counter elelctrode and the rebars on real structures and localized corrosion attacks. In this work results from laboratory experiments on macrocell corrosion are presented, showing the influence of resistivity and geometrical arrangement on the macrocell corrosion rate under open circuit conditions and under an external anodic pulse. From the results it can be concluded that the polrization resistance measured experimentally corresponds to the corrosion rate of the anode in the macrocell, Most of the imposed current is flowing to the local anode and thus signal confinement for local corrosion attacks is not necessary. The segmented counter electrode opens a way to determined localized corrosion rates.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 50 条
  • [1] Corrosion rate of steel in concrete - From laboratory to reinforced concrete structures
    Elsener, B
    CORROSION OF REINFORCEMENT IN CONCRETE: MONITORING, PREVENTION AND REHABILITATION, 1998, (25): : 92 - 103
  • [2] Corrosion rate of steel in concrete - from laboratory to reinforced structures
    Elsener, B.
    Materials Science Forum, 1997, 247 : 127 - 138
  • [4] Investigation of corrosion of steel stirrups in reinforced concrete structures
    Lu, Zhao-Hui
    Ou, Yi-Bin
    Zhao, Yan-Gang
    Li, Chun-Qing
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 127 : 293 - 305
  • [5] Monitoring Corrosion of Steel Bars in Reinforced Concrete Structures
    Verma, Sanjeev Kumar
    Bhadauria, Sudhir Singh
    Akhtar, Saleem
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [6] Steel corrosion and service life of reinforced concrete structures
    Bertolini, Luca
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2008, 4 (02) : 123 - 137
  • [7] Empirical model of corrosion rate for steel reinforced concrete structures in chloride-laden environments
    Lu, Zhao-Hui
    Lun, Pei-Yuan
    Li, Wengui
    Luo, Zhiyu
    Li, Yuelin
    Liu, Peng
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (01) : 223 - 239
  • [9] Steel-Reinforced Concrete Structures: Assessment and Repair of Corrosion
    Seifert, Lando
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2020, 71 (08): : 1408 - 1409
  • [10] On-site measurements on corrosion rate of steel in reinforced concrete
    Department of Architectural Engineering, Seonam University, Jeonbuk, Korea, Republic of
    不详
    不详
    不详
    ACI Mater J, 2007, 6 (638-642):