Preclinical evaluation of a novel device for delivering brachytherapy to the margins of resected brain tumor cavities

被引:14
|
作者
Stubbs, JB
Frankel, RH
Schultz, K
Crocker, I
Dillehay, D
Olson, JJ
机构
[1] Proxima Therapeut Inc, Alpharetta, GA USA
[2] Emory Univ, Sch Med, Div Anim Resources, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Neurosurg, Atlanta, GA 30322 USA
[4] Emory Univ, Sch Med, Dept Pathol, Atlanta, GA 30322 USA
[5] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
brachytherapy; glioma; resection; radiation therapy; dog;
D O I
10.3171/jns.2002.96.2.0335
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The objectives of this study were to evaluate the safety and performance of a new brachytherapy applicator in the treatment of resected brain tumors in a canine model. Methods. The brachytherapy applicator is an inflatable balloon catheter that is implanted in the resection cavity remaining after a brain tumor has been debulked. After implantation the balloon is inflated with Iotrex, a sterile solution containing organically bound iodine-125. The low-energy photons emitted by the iodine-125 deposit a therapeutic radiation dose across short distances from the surface of the balloon. After delivery of a prescribed radiation dose to the targeted volume, the radioactive fluid is retrieved and the catheter removed. Small resections of the right frontal lobe were performed in large dogs. Magnetic resonance (MR) images were obtained and used to assess tissue response and to measure the conformance between the resection cavity wall and the balloon surface. In four animals a dose ranging from 36 to 59 Gy was delivered. Neurological status and histological characteristics of the brain were assessed. in all dogs. Implantation and explantation as well as inflation and deflation of the device were easily accomplished and well tolerated. The device was easily visualized on MR images, which demonstrated the expected postsurgical changes. The resection cavity and the balloon were highly conformal (range 93-100%). Histological changes to the cavity margin were consistent with those associated with surgical trauma. Additionally, radiation-related changes were observed at the margins of the resection cavity in dogs in which the brain was irradiated. Conclusions. This balloon catheter and I-125 radiotherapy solution system can safely and reliably deliver radiation to the margins of brain cavities created by tumor resection. Results of this study showed that intracranial pressure changes due to balloon inflation and deflation were unremarkable and characteristic of the imaging properties and radiation safety profile of the device prior to its clinical evaluation. Clinically relevant brachytherapy (adequate target volume and total dose) was accomplished in all four animals subjected to treatment.
引用
收藏
页码:335 / 343
页数:9
相关论文
共 50 条
  • [1] Dosimetric Evaluation of Permanent Brachytherapy Radioisotopes for Resected Metastatic Brain Tumors
    Badkul, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E244 - E244
  • [2] Dosimetric properties of a novel brachytherapy balloon applicator for the treatment of malignant brain-tumor resection-cavity margins
    Dempsey, JF
    Williams, JA
    Stubbs, JB
    Patrick, TJ
    Williamson, JF
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02): : 421 - 429
  • [3] The Dosimetric Evaluation of Cesium 131 Brachytherapy Permanent Implants for Resected Brain Tumors
    Badkul, R.
    Butler-xu, Y.
    Jiang, H.
    Demez, N.
    Awan, S.
    Saleh, H.
    Wang, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E858 - E859
  • [4] Dosimetric properties of a novel brachytherapy balloon applicator for the treatment of malignant brain-tumor resection-cavity margins
    Dempsey, James F.
    Williams, Jeffery A.
    Stubbs, James B.
    Patrick, Timothy J.
    Williamson, Jeffrey F.
    International Journal of Radiation Oncology, Biology, Physics, 42 (02): : 421 - 429
  • [5] Evaluation of a Balloon Implant for Simultaneous Magnetic Nanoparticle Hyperthermia and High-Dose-Rate Brachytherapy of Brain Tumor Resection Cavities
    Wan, Shuying
    Rodrigues, Dario B.
    Kwiatkowski, Janet
    Khanna, Omaditya
    Judy, Kevin D.
    Goldstein, Robert C.
    Bloem, Marty Overbeek
    Yu, Yan
    Rooks, Sophia E.
    Shi, Wenyin
    Hurwitz, Mark D.
    Stauffer, Paul R.
    CANCERS, 2023, 15 (23)
  • [6] Preclinical Pharmacological Evaluation of a Novel Multiple Kinase Inhibitor, ON123300, in Brain Tumor Models
    Zhang, Xiaoping
    Lv, Hua
    Zhou, Qingyu
    Elkholi, Rana
    Chipuk, Jerry E.
    Reddy, M. V. Ramana
    Reddy, E. Premkumar
    Gallo, James M.
    MOLECULAR CANCER THERAPEUTICS, 2014, 13 (05) : 1105 - 1116
  • [7] Preclinical evaluation of a novel extracorporeal bioartificial liver device (BAL).
    Block, GD
    Amiot, B
    Patzer, JF
    HEPATOLOGY, 1996, 24 (04) : 1434 - 1434
  • [8] Cryobiopsy in the Upper Urinary Tract: Preclinical Evaluation of a Novel Device
    Klein, Jan-Thorsten
    Berger, Franziska
    Linzenbold, Walter
    Jaeger, Luise
    Enderle, Markus D.
    Boesmueller, Hans
    Mundhenk, Jens
    Schwentner, Christian
    Bolenz, Christian
    UROLOGY, 2019, 123 : 273 - 279
  • [9] Preclinical safety evaluation of a novel helical rotational thrombectomy device
    Future, Adrian
    Houser, Stuart L.
    Wood, Todd
    Howk, Kreg A.
    Simmons, Quincey R.
    Sauro, Dennis
    Badway, Dan
    Smith, Chad
    Giugliano, Gregory R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 35B - 35B
  • [10] Development of a Novel Dual-Modality Balloon Implant for Simultaneous HDR Brachytherapy and Magnetic Nanoparticle Hyperthermia of Brain Tumor Resection Cavities
    Wan, S.
    Rodrigues, D.
    Stauffer, P.
    Yu, Y.
    Kwiatkowski, J.
    Judy, K.
    Khanna, O.
    Bloem, M.
    Goldstein, R.
    Hurwitz, M.
    Shi, W.
    MEDICAL PHYSICS, 2021, 48 (06)