Effect of Artificial Saliva Storage on Microhardness and Fracture Toughness of a Hydrothermal Glass-Ceramic

被引:10
|
作者
Fahmy, Nadia Z. [1 ]
El Guindy, Jylan [2 ]
Zamzam, Mohamed [2 ]
机构
[1] October 6 Univ, Dept Fixed Prosthodont, Fac Dent, Cairo 11511, Giza Governorat, Egypt
[2] Cairo Univ, Fac Oral & Dent Med, Dept Fixed Prosthodont, Cairo, Egypt
关键词
Artificial saliva; microhardness; fracture toughness; surface finish; hydrothermal glass-ceramic;
D O I
10.1111/j.1532-849X.2009.00448.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the effect of artificial saliva storage on the hardness, crack length, and fracture toughness of a glazed, polished, and bleached hydrothermal low-fusing glass-ceramic (Duceram LFC). Materials and Methods: Forty ceramic discs were constructed. The discs were assigned to four groups (n = 10) according to their surface finish: Gp1-Autoglaze, Gp2-Autoglaze/ground/diamond-polished, Gp3-Overglaze, Gp4-Overglaze/ground/diamond-polished. Each group was further divided into two subgroups forming eight total subgroups (n = 5). Subgroup A was unbleached; Subgroup B was bleached. Testing was performed before and after 21 days of artificial saliva storage. Data were presented as means and standard deviation (SD). ANOVA was used, along with Duncan's post hoc test for pairwise comparison between the means when ANOVA test was found significant (p <= 0.05). Results: Surface treatments such as glazing, polishing, and bleaching, saliva storage, and the interaction between these variables had a statistically significant effect on mean values of microhardness, crack length, and fracture toughness of the specimens. There was a statistically significant increase in microhardness and fracture toughness mean values, while crack length values decreased after saliva storage. Polished specimens recorded the smallest crack lengths and fracture toughness, and highest hardness values before and after saliva storage. No difference in fracture toughness values was evident between glazed and polished specimens. Mean crack lengths decreased after saliva storage in all the tested specimens. Hardness values increased after saliva storage. The autoglazed group showed significantly higher fracture toughness, lower crack length, and microhardness than the overglazed group. Conclusions: Surface finishing procedures and artificial saliva storage had a statistically significant effect on mean values of microhardness, crack length, and fracture toughness. This in vitro study suggests that fracture toughness of ceramics may be affected by different surface treatments such as glazing, polishing, bleaching, or a combination; however, in this study Duceram LFC proved its self-healing property after 3-week storage in artificial saliva.
引用
收藏
页码:324 / 331
页数:8
相关论文
共 50 条
  • [1] Effect of nucleation temperature on fracture toughness (KIC) of fluorcanasite-based glass-ceramic
    Oh, WS
    Zhang, NZ
    Anusavice, KJ
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (05) : 505 - 509
  • [2] EFFECT OF CRYSTALLINITY ON STRENGTH AND FRACTURE-TOUGHNESS OF LITHIA-BASED GLASS-CERAMIC
    ANUSAVICE, KJ
    ZHANG, NZ
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 218 - 218
  • [3] Influence of interfacial strength on the fracture toughness of glass-ceramic matrix composites
    Lingsen Wang
    Ruoyu Liu
    Jinsen Zang
    Yi Fan
    Journal of Central South University of Technology, 1997, 4 (1): : 1 - 4
  • [4] INFLUENCE OF INTERFACIAL STRENGTH ON THE FRACTURE TOUGHNESS OF GLASS-CERAMIC MATRIX COMPOSITEST
    Wang Lingsen
    Liu Ruoyu
    Zang Jinsen
    Fan Yi(PowderMetallurgy Research institute
    Journal of Central South University of Technology(English Edition), 1997, (01) : 1 - 4
  • [5] Influence of interfacial strength on the fracture toughness of glass-ceramic matrix composites
    Wang, Lingsen
    Liu, Ruoyu
    Zang, Jinsen
    Fan, Yi
    Journal of Central South University of Technology (English Edition), 1997, 4 (01): : 1 - 4
  • [6] INDENTER FLAW GEOMETRY AND FRACTURE-TOUGHNESS ESTIMATES FOR A GLASS-CERAMIC
    SHETTY, DK
    ROSENFIELD, AR
    DUCKWORTH, WH
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1985, 68 (10) : C282 - C284
  • [8] Elastic properties and fracture toughness of SiOC-based glass-ceramic nanocomposites
    To, Theany
    Stabler, Christina
    Ionescu, Emanuel
    Riedel, Ralf
    Celarie, Fabrice
    Rouxel, Tanguy
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2020, 103 (01) : 491 - 499
  • [9] Tribological behavior of zirconia-reinforced glass-ceramic composites in artificial saliva
    Santos, R. L. P.
    Buciumeanu, M.
    Silva, F. S.
    Souza, J. C. M.
    Nascimento, R. M.
    Motta, F. V.
    Henriques, B.
    TRIBOLOGY INTERNATIONAL, 2016, 103 : 379 - 387
  • [10] EFFECT OF RIBBON ORIENTATION ON THE FRACTURE-TOUGHNESS OF A METALLIC-GLASS-RIBBON-REINFORCED GLASS-CERAMIC MATRIX COMPOSITE
    VAIDYA, RU
    SUBRAMANIAN, KN
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1990, 73 (10) : 2962 - 2964