Atherosclerotic carotid bifurcation phantoms with stenotic soft inclusions for ultrasound flow and vessel wall elastography imaging

被引:19
|
作者
Chayer, Boris [1 ]
van den Hoven, Marcel [1 ,2 ]
Cardinal, Marie-Helene Roy [1 ]
Li, Hongliang [1 ,3 ]
Swillens, Abigail [4 ]
Lopata, Richard [2 ]
Cloutier, Guy [1 ,3 ,5 ]
机构
[1] Univ Montreal Hosp Res Ctr CRCHUM, Lab Biorheol & Med Ultrason, Montreal, PQ, Canada
[2] Eindhoven Univ Technol, Dept Biomed Engn, Eindhoven, Netherlands
[3] Univ Montreal, Inst Biomed Engn, Montreal, PQ, Canada
[4] Univ Ghent, IBiTech BioMMeda, Ghent, Belgium
[5] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 09期
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
vascular phantom; carotid atherosclerotic plaque; duplex ultrasound; shear wave elastography; strain elastography; flow loop experiments; phantom fabrication process; VALIDATION; ELASTICITY; STIFFNESS; QUANTIFICATION; HEMODYNAMICS; SIMULATION; MODULUS; ARTERY;
D O I
10.1088/1361-6560/ab1145
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As the complexity of ultrasound signal processing algorithms increases, it becomes more difficult to demonstrate their added value and thus robust validation strategies are required. We propose a method of manufacturing ultrasonic vascular phantoms mimicking an atheromatous plaque in an internal carotid artery bifurcation for applications in flow imaging and elastography. During the fabrication process, a soft inclusion mimicking a stenotic lipid pool was embedded within the vascular wall. Mechanical testing measured Young's moduli of the vascular wall and soft inclusion at 342 +/- 25 kPa and 17 +/- 3 kPa, respectively. B-mode, color Doppler, power Doppler, shear wave elastography, and strain elastography images of the different phantoms were produced to show the validity of the fabrication process. Because of their realistic geometries and mechanical properties, those phantoms may become advantageous for fluid-structure experimental modeling and validation of new ultrasound-based imaging technologies.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Atherosclerotic carotid bifurcation phantoms with a stenotic soft inclusion for flow-structure ultrasound imaging analysis
    Chayer, Boris
    van den Hoven, Marcel
    Cardinal, Marie-Helene Roy
    Li, Hongliang
    Madiena, Craig
    Swillens, Abigail
    Lopata, Richard
    Cloutier, Guy
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1216 - 1218
  • [2] Anthropomorphic Carotid Artery Phantom for Ultrasound Flow and Vessel Wall Elastography Imaging
    Almutairi, Fahad F. F.
    Alyami, Jaber H. H.
    CURRENT MEDICAL IMAGING, 2023, 19 (11) : 1324 - 1336
  • [3] Walled Carotid Bifurcation Phantoms for Imaging Investigations of Vessel Wall Motion and Blood Flow Dynamics
    Chee, Adrian J. Y.
    Ho, Chung Kit
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (11) : 1852 - 1864
  • [4] PRESSURE DIFFERENCE ESTIMATION IN NON-STENOTIC CAROTID BIFURCATION PHANTOMS USING VECTOR FLOW IMAGING
    Nguyen, Tin-Quoc
    Traberg, Marie Sand
    Olesen, Jacob Bjerring
    Moshavegh, Ramin
    Moller-Sorensen, Peter Hasse
    Lonn, Lars
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    Hansen, Kristoffer Lindskov
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (02): : 346 - 357
  • [5] Design of Anthropomorphic Atherosclerotic Carotid Artery Flow Phantoms for Ultrasound Images
    Galluzzo, Francesca
    Leonardo, Filippo
    Ceruti, Alessandro
    De Marchi, Luca
    Corsi, Cristiana
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 721 - 724
  • [6] Blood flow dynamics in carotid bifurcation and vessel wall changes
    Remuzzi, A
    Piccinelli, M
    Antiga, L
    Caverni, L
    De Monti, M
    BIOMEDICINE & PHARMACOTHERAPY, 2004, 58 (08) : 463 - 463
  • [7] Characteristics and Correlations of Wall Shear Stress and Flow Turbulence in the Carotid Bifurcation Evaluated Using an Ultrasound Vector Flow Imaging
    Liu, Mengmeng
    Song, Di
    Hong, Shaofu
    Dong, Yinghui
    Gao, Wenjing
    Du, Yigang
    Zhu, Lei
    Xu, Jinfeng
    Dong, Fajin
    JOURNAL OF VASCULAR RESEARCH, 2024, 61 (01) : 38 - 49
  • [8] Anatomical flow phantoms of the nonplanar carotid bifurcation, part II: Experimental validation with Doppler ultrasound
    Meagher, S.
    Poepping, T. L.
    Ramnarine, K. V.
    Black, R. A.
    Hoskins, P. R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (02): : 303 - 310
  • [9] Fast Von Mises strain imaging on ultrasound carotid vessel wall by flow driven diffusion method
    Zhang, HongMei
    Song, ManMan
    Yang, Ming
    Song, Yan
    Zhang, FuRong
    Zhang, AiFeng
    Ruan, LiTao
    Wan, MingXi
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (03) : 669 - 686
  • [10] Fast Von Mises strain imaging on ultrasound carotid vessel wall by flow driven diffusion method
    HongMei Zhang
    ManMan Song
    Ming Yang
    Yan Song
    FuRong Zhang
    AiFeng Zhang
    LiTao Ruan
    MingXi Wan
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 669 - 686