Optical Coherence Tomography Angiography in Mice: Quantitative Analysis After Experimental Models of Retinal Damage

被引:12
|
作者
Smith, Corey A. [1 ,2 ]
Hooper, Michele L. [2 ,3 ]
Chauhan, Balwantray C. [1 ,2 ,3 ]
机构
[1] Dalhousie Univ, Dept Ophthalmol & Visual Sci, 1276 South Pk St,Victoria Bldg,Room 2035, Halifax, NS B3H 2Y9, Canada
[2] Dalhousie Univ, Retina & Opt Nerve Res Lab, Halifax, NS, Canada
[3] Dalhousie Univ, Dept Physiol & Biophys, Halifax, NS, Canada
基金
加拿大健康研究院;
关键词
mice; optical coherence tomography angiography; experimental disease models; OCT ANGIOGRAPHY; MOUSE RETINA; OXYGEN; MICROVASCULATURE; QUANTIFICATION; PERIPAPILLARY; CONSUMPTION; EXPRESSION; GLAUCOMA; CELLS;
D O I
10.1167/iovs.18-26441
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We implemented optical coherence tomography angiography (OCT-A) in mice to: (1) develop quantitative parameters from OCT-A images, (2) measure the reproducibility of the parameters, and (3) determine the impact of experimental models of inner and outer retinal damage on OCT-A findings. METHODS. OCT-A images were acquired with a customized system (Spectralis Multiline OCT2). To assess reproducibility, imaging was performed five times over 1 month. Inner retinal damage was induced with optic nerve transection, crush, or intravitreal N-methyl-d-aspartic acid injection in transgenic mice with fluorescently labeled retinal ganglion cells (RGCs). Light-induced retinal damage was induced in albino mice. Mice were imaged at baseline and serially post injury. Perfusion density, vessel length, and branch points were computed from OCT-A images of the superficial, intermediate, and deep vascular plexuses. RESULTS. The range of relative differences measured between sessions across the vascular plexuses were: perfusion density (2.8%-7.0%), vessel length (1.9%-4.1%), and branch points (1.9%-5.0%). In mice with progressive RGC loss, imaged serially and culminating in around 70% loss in the fluorescence signal and 18% loss in inner retinal thickness, there were no measurable changes in any OCT-A parameter up to 4 months post injury that exceeded measurement variability. However, light-induced retinal damage elicited a progressive loss of the deep vascular plexus signal, starting as early as 3 days post injury. CONCLUSIONS. Vessel length and branch points were generally the most reproducible among the parameters. Injury causing RGC loss in mice did not elicit an early change in the OCT-A signal.
引用
收藏
页码:1556 / 1565
页数:10
相关论文
共 50 条
  • [1] Quantitative analysis of retinal perfusion in mice using optical coherence tomography angiography
    Alnawaiseh, Maged
    Brand, Cristin
    Bormann, Eike
    Wistuba, Joachim
    Eter, Nicole
    Heiduschka, Peter
    EXPERIMENTAL EYE RESEARCH, 2017, 164 : 151 - 156
  • [2] Quantitative Microvascular Analysis of Retinal Venous Occlusion by Optical Coherence Tomography Angiography
    Koulisis, Nicole
    Kim, Alice Yon
    Chu, Zhongdi
    Shahidzadeh, Anoush
    Wang, Ruikang K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Qualitative and Quantitative Analysis of Optical Coherence Tomography Angiography in Patients with Retinal Vasculitis
    Bessette, Angela P.
    Levison, Ashleigh Laurin
    Baynes, Kimberly
    Lowder, Careen Y.
    Srivastava, Sunil K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [4] Optical coherence tomography angiography quantitative analysis of retinal and choroidal microvasculature in patients with dyslipidemia
    Remoli Sargues, Lidia
    Monferrer Adsuara, Clara
    Castro Navarro, Veronica
    Navarro Palop, Catalina
    Montero Hernandez, Javier
    Cervera Taulet, Enrique
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : 1666 - 1671
  • [5] Automated Quantitative Analysis of Retinal Microvasculature in Normal Eyes on Optical Coherence Tomography Angiography
    Lupidi, Marco
    Coscas, Florence
    Cagini, Carlo
    Fiore, Tito
    Spaccini, Elisa
    Fruttini, Daniela
    Coscas, Gabriel
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 9 - 23
  • [6] Quantitative Retinal Microvascular Analysis in Schizophrenia With Swept Source Optical Coherence Tomography Angiography
    Bannai, Deepthi
    Adhan, Iniya
    Kasetty, Megan
    Kim, Leo A.
    Hill, Scot
    Tamminga, Carol
    Gershon, Elliot
    Keedy, Sarah
    Pearlson, Godfrey
    Keshavan, Matcheri
    Miller, John B.
    Lizano, Paulo
    BIOLOGICAL PSYCHIATRY, 2021, 89 (09) : S276 - S277
  • [7] Quantitative assessment of the retinal microvasculature using optical coherence tomography angiography
    Chu, Zhongdi
    Lin, Jason
    Gao, Chen
    Xin, Chen
    Zhang, Qinqin
    Chen, Chieh-Li
    Roisman, Luis
    Gregori, Giovanni
    Rosenfeld, Philip J.
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [8] Optical Coherence Tomography Angiography Analysis Toolbox: A Repeatable and Reproducible Software Tool for Quantitative Optical Coherence Tomography Angiography Analysis
    Girgis, Jessica M.
    Saukkonen, Daniel
    Huther, Alexander
    Alibhai, A. Yasin
    Moult, Eric M.
    Abu-Qamar, Omar
    Fujimoto, James G.
    Baumal, Caroline R.
    Witkin, Andre J.
    Duker, Jay S.
    Waheed, Nadia K.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2023, 54 (02): : 114 - 122
  • [9] Optical Coherence Tomography and Optical Coherence Tomography Angiography in Pediatric Retinal Diseases
    Wang, Chung-Ting
    Chang, Yin-Hsi
    Tan, Gavin S. W.
    Lee, Shu Yen
    Chan, R. V. Paul
    Wu, Wei-Chi
    Tsai, Andrew S. H.
    DIAGNOSTICS, 2023, 13 (08)
  • [10] Quantitative Analysis of Retinal Perfusion in Patients with Frontotemporal Dementia Using Optical Coherence Tomography Angiography
    Esser, Eliane Luisa
    Lahme, Larissa
    Dierse, Sebastian
    Diener, Raphael
    Eter, Nicole
    Wiendl, Heinz
    Duning, Thomas
    Pawlowski, Matthias
    Kraemer, Julia
    Alnawaiseh, Maged
    DIAGNOSTICS, 2024, 14 (02)