Local vs. integrated control strategies for double-skin systems

被引:14
|
作者
Park, Cheol-Soo [1 ]
Augenbroe, Godfried [2 ]
机构
[1] Sungkyunkwan Univ, Coll Engn, Dept Architectural Engn, Suwon 440746, South Korea
[2] Georgia Inst Technol, Coll Architecture, Atlanta, GA 30332 USA
基金
新加坡国家研究基金会;
关键词
Double Skin; Control; Performance; Optimization; Integrated; GREY-BOX MODEL; FACADE;
D O I
10.1016/j.autcon.2012.11.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the follow-up in the development of occupant responsive optimal control for double-skin systems that was published previously in Park et al. [1]. The presented occupant responsive optimal control optimizes in real-time the performance of the facade in terms of energy, visual comfort (average daylight interior illuminance, uniformity, average window luminance, and outward visibility) and thermal comfort (Predicted Percentage Dissatisfied, PPD). In the aforementioned approach, the double-skin facade system was viewed as an 'isolated' system and hence treated as a local control problem, i.e., based purely on information about the state of the facade and its immediate environment. The paper extends the local control problem to an integrated control problem in which room environmental control and facade control are dealt with simultaneously. It was found that the local control leads to sub-optimality, albeit of moderate proportions. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 56
页数:7
相关论文
共 50 条
  • [1] Simulation of the thermal performance of a geometrically complex Double-Skin Facade for hot climates: EnergyPlus vs. OpenFOAM
    El Ahmar, Salma
    Battista, Francesco
    Fioravanti, Antonio
    [J]. BUILDING SIMULATION, 2019, 12 (05) : 781 - 795
  • [2] Simulation of the thermal performance of a geometrically complex Double-Skin Facade for hot climates: EnergyPlus vs. OpenFOAM
    Salma El Ahmar
    Francesco Battista
    Antonio Fioravanti
    [J]. Building Simulation, 2019, 12 : 781 - 795
  • [3] Nonlinear control systems modelling: Global vs. local
    Dzielinski, A
    Graniszewski, W
    [J]. PROCEEDINGS OF THE 2002 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2002, 1-6 : 537 - 542
  • [4] Natural cooling strategies efficiency in an office building with a double-skin facade
    Gratia, E
    De Herde, A
    [J]. ENERGY AND BUILDINGS, 2004, 36 (11) : 1139 - 1152
  • [5] Calibration of a lumped simulation model for double-skin facade systems
    Park, CS
    Augenbroe, G
    Messadi, T
    Thitisawat, M
    Sadegh, N
    [J]. ENERGY AND BUILDINGS, 2004, 36 (11) : 1117 - 1130
  • [6] The study of a double-skin ventilated window integrated with CdTe cells in a rural building
    Wang, Chuyao
    Ji, Jie
    Uddin, Md Muin
    Yu, Bendong
    Song, Zhiying
    [J]. ENERGY, 2021, 215
  • [7] Elite Bias Genetic Algorithm for Optimal Control of Double-skin Facade
    Xu Xingtian
    Chen Xi
    [J]. 2015 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION (CEC), 2015, : 3354 - 3361
  • [8] Structural Performance of Double-Skin Facade Systems Subjected to Blast Pressures
    Tuan Ngo
    Ding, Chao
    Lumantarna, Raymond
    Ghazlan, Abdallah
    Zobec, Marc
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (12)
  • [9] Smoke control through a double-skin facade used for natural ventilation
    Ding, Wenting
    Hasemi, Yuji
    [J]. ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 181 - +
  • [10] Local vs. regional vs. global supply development strategies for the global detergent industry
    Urban, GF