FasT-Fix Meniscal Repair: Mid-term Results

被引:61
|
作者
Barber, F. Alan [1 ]
Schroeder, F. Alexander [1 ]
Oro, Fernando Barrera [2 ]
Beauis, R. Cole [3 ]
机构
[1] Plano Orthoped & Sports Med Ctr, Plano, TX 75093 USA
[2] Cent Mil Hosp, Arthroscopy Serv, Buenos Aires, DF, Argentina
[3] Univ Saskatchewan, Div Orthoped Surg, Saskatoon, SK, Canada
关键词
Accelerated rehabilitation; Arthroscopy; FasT-Fix; Meniscus; Repair device;
D O I
10.1016/j.arthro.2008.08.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the clinical success of the FasT-Fix meniscal repair device (Smith & Nephew Endoscopy. Andover, MA) associated with an accelerated rehabilitation program. Methods: A prospectively collected consecutive series of meniscal repairs performed with the FasT-Fix device was studied. The Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee activity scores, along with the clinical examination findings and adverse events, were recorded for all patients. Associated procedures were recorded. An accelerated postoperative rehabilitation program was followed, independent of concurrent anterior cruciate ligament surgery. Results: Forty-one meniscal repairs were performed, with an average follow-up of 30.7 months (range. 12 to 58 months). Twenty-nine of 41 repairs were performed in conjunction with anterior cruciate ligment reconstruction. The other repairs were in stable knees. There were 26 medial and 15 lateral meniscus repairs. Both menisci were repaired in 5 knees. Repeat arthroscopies were performed for 12 repairs and 7 (17%) were found to have failed. The preoperative and postoperative Lysholm. Tegner, Cincinnati, and International Knee Documentation Committee activity scores were 47.3 and 87.4, 3.4 and 7.2, 38.7 and 82.8, and 2.3 and 3.4, respectively. Conclusions: The FasT-Fix meniscal repair associated with an accelerated rehabilitation program resulted in clinically effective meniscal repair in 83% at the time of follow-up. Clinical outcome measures all improved. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:1342 / 1348
页数:7
相关论文
共 50 条
  • [1] Results of all-inside meniscal repair with the FasT-Fix meniscal repair system
    Kotsovolos, ES
    Hantes, ME
    Mastrokalos, DS
    Lorbach, O
    Paessler, HH
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (01): : 3 - 9
  • [2] Pitfalls associated with FasT-Fix meniscal repair
    Miller, MD
    Kline, AJ
    Gonzales, J
    Beach, WR
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (08): : 939 - 943
  • [3] Arthroscopic meniscal repair using the fast-fix system
    Sexton, P.
    Moran, C.
    Ferguson, D.
    Waters, P.
    Roche, S.
    Shannon, F.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S102 - S102
  • [4] Meniscal repair using the FasT-Fix all-inside meniscal repair device
    Haas, AL
    Schepsis, AA
    Hornstein, J
    Edgar, CM
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (02): : 167 - 175
  • [5] Meniscal repair using the FasT-Fix device in patients with chronic meniscal lesions
    Popescu, Dragos
    Sastre, Sergi
    Caballero, Miguel
    Lee, Jin Woo Kim
    Claret, Ignasi
    Nunez, Montserrat
    Lozano, Luis
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (04) : 546 - 550
  • [6] Meniscal repair using the FasT-Fix device in patients with chronic meniscal lesions
    Dragos Popescu
    Sergi Sastre
    Miguel Caballero
    Jin Woo Kim Lee
    Ignasi Claret
    Montserrat Nuñez
    Luis Lozano
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 546 - 550
  • [7] Long-term outcome after all inside meniscal repair using the FasT-Fix system
    Zimmerer, Alexander
    Sobau, Christian
    Nietschke, Rainer
    Schneider, Marco
    Ellermann, Andree
    [J]. JOURNAL OF ORTHOPAEDICS, 2018, 15 (02) : 602 - 605
  • [8] FasT-Fix Versus Inside-Out Suture Meniscal Repair in the Goat Model
    Hospodar, Steven J.
    Schmitz, Matthew R.
    Golish, S. Raymond
    Ruder, Craig R.
    Miller, Mark D.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (02): : 330 - 333
  • [9] Using the fast-fix device in arthroscopic all-inside repair of meniscal tears
    Sexton, P.
    Moran, C. J.
    Ferguson, D.
    Shannon, F. J.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S259 - S260
  • [10] A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus
    Kocabey, Y
    Chang, HC
    Brand, JC
    Nawab, A
    Nyland, J
    Caborn, DNM
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (04): : 406 - 413