Variance components associated with long-echo-time MR spectroscopic imaging in human brain at 1.5T and 3T

被引:0
|
作者
Thrippleton, Michael J. [1 ]
Parikh, Jehill P. [1 ]
Semple, Scott I. K. [2 ]
Harris, Bridget A. [3 ]
Andrews, Peter J. D. [1 ]
Wardlaw, Joanna M. [1 ]
Marshall, Ian [1 ]
机构
[1] Univ Edinburgh, Ctr Clin Brain Sci, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Clin Res Imaging Ctr, Edinburgh, Midlothian, Scotland
[3] Univ Edinburgh, Crit Care Med, Edinburgh, Midlothian, Scotland
来源
PLOS ONE | 2017年 / 12卷 / 12期
关键词
REFOCUSING PULSES; WHITE-MATTER; REPRODUCIBILITY; QUANTIFICATION; METABOLITES; RELIABILITY; ACCURATE; IMAGES; ROBUST; COILS;
D O I
10.1371/journal.pone.0189872
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object Magnetic resonance spectroscopic imaging (MRSI) is increasingly used in medicine and clinical research. Previous reliability studies have used small samples and focussed on limited aspects of variability; information regarding 1.5T versus 3T performance is lacking. The aim of the present work was to measure the inter-session, intra-session, inter-subject, within-brain and residual variance components using both 1.5T and 3T MR scanners. Materials and methods Eleven healthy volunteers were invited for MRSI scanning on three occasions at both 1.5T and 3T, with four scans acquired at each visit. We measured variance components, correcting for grey matter and white matter content of voxels, of metabolite peak areas and peak area ratios. Results Residual variance was in general the largest component at 1.5T (8.6-24.6%), while withinbrain variation was the largest component at 3T (12.0-24.7%). Inter-subject variation was around 5%, while inter- and intra-session variance were both generally small. Conclusion Multiple variance contributions associated with MRSI measurements were quantified and the performance of 1.5T and 3T MRI scanners compared using data from the same group of subjects. Residual error is much lower at 3T, but other variance components remain important.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] MR Spectroscopic Imaging of Benign Prostatic Tissue: Findings at 3T Compared to 1.5T Initial Experience
    Chitkara, M.
    Westphalen, A.
    Kurhanewicz, J.
    Qayyum, A.
    Poder, L.
    Reed, G.
    Coakley, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [2] Comparison of 1.5T and 3T 1H MR spectroscopy for human brain tumors
    Kim, Ji-hoon
    Chang, Kee-Hyun
    Na, Dong Gyu
    Song, In Chan
    Kim, Seung Ja
    Kwon, Bae Ju
    Han, Moon Hee
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (03) : 156 - 161
  • [3] Comparison of Diffusion Metrics Obtained at 1.5T and 3T in Human Brain With Diffusional Kurtosis Imaging
    Shaw, Calvin B.
    Jensen, Jens H.
    Deardorff, Rachael L.
    Spampinato, Maria Vittoria
    Helpern, Joseph A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (03) : 673 - 680
  • [4] COMPARING BETWEEN MR SPECTROSCOPY DONE AT 1.5T AND 3T
    Tang, Phua Hwee
    Nisa, Sameema
    NEURO-ONCOLOGY, 2022, 24 : 77 - 77
  • [5] MR Diagnosis of Bone Metastases at 1.5T and 3T: Can STIR Imaging Be Omitted?
    Ohlmann-Knafo, S.
    Tarnoki, A. D.
    Tarnoki, D. L.
    Pickuth, D.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (10): : 924 - 932
  • [6] Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T
    Downs, Richard Keith
    Bashir, Mariah Haider
    Ng, Chin Kau
    Heidenreich, Jens Olaf
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2013, 3 (03) : 141 - 146
  • [7] Neurovascular contact in trigeminal neuralgia. A comparison between 3T and 1.5T MR imaging
    Echeveste, B. E.
    Minguez, A.
    Imaz, L.
    Trzeciak, M.
    Barriobero, N.
    Arregui, A.
    Trevino, C.
    Garcia de Eulate, R.
    Dominguez, P.
    Zubieta, J. L.
    Martinez-Vila, E.
    Irimia, P.
    CEPHALALGIA, 2015, 35 : 254 - 254
  • [8] Evaluation of optimised 3D turbo spin echo and gradient echo MR pulse sequences of the knee at 3T and 1.5T
    Abdulaal, O. M.
    Rainford, L.
    MacMahon, P. J.
    Kenny, P.
    Carty, F.
    Galligan, M.
    Cradock, A.
    Alhazmi, F. H.
    McGee, A.
    RADIOGRAPHY, 2021, 27 (02) : 389 - 397
  • [9] What you Need to Know About MR Neuroimaging at 1.5T and 3T
    Tanenbaum, L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [10] Test-Retest Reliability and Reproducibility of Short-Echo-Time Spectroscopic Imaging of Human Brain at 3T
    Gasparovic, Charles
    Bedrick, Edward J.
    Mayer, Andrew R.
    Yeo, Ronald A.
    Chen, HongJi
    Damaraju, Eswar
    Calhoun, Vince D.
    Jung, Rex E.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 324 - 332