摘要
AIM: To evaluate the effectiveness and safety of complex orbital fracture reconstruction with titanium implants. METHODS: A retrospective review of 46 patients treated with complex orbital fractures reconstruction using titanium implants from January 2005 to December 2008 was conducted. The following data were recorded: age, gender, mechanism of injury, preoperative and postoperative orbital CT, visual acuity, diplopia, ocular motility and Hertel exophthalmometer. RESULTS: The most common cause was motor vehicle accident (47.8%), followed by industrial injury (30.4%). All patients had improved appearance after operation and CT scan at one week after operation showed the fracture defects of orbit and neighboring areas had been reconstructed. Forty-six cases had various degrees of enophthalmos before operation. Among them, 32 cases were completely corrected, 11 cases improved obviously and 3 cases had no improvement after operation. Thirty-six patients with visual acuity =20/60 revealed diplopia of various degrees, including 26 patients had diplopia in right ahead and/or reading positions. At the sixth month after operation, diplopia disappeared in five patients, 7 patients still had diplopia in right ahead and/or reading positions, 14 patients had diplopia in positions rather than right ahead and reading positions (<20 degrees) and ten patients had diplopia only at peripheral gazing (>20 degrees). All patients had various degrees of ocular motility disorders before operation. At the sixth month after operation, eyeball movement disorder disappeared in 9 patients, 31 patients showed improvement and 6 patients had no improvement. Complications of implant infection, rejection and displacement were not reported after operation. CONCLUSION: The application of titanium implants in the repair of complex orbital fractures greatly improves the appearance and functional results, which is a favorable material for plastic surgery of complex orbital fracture.
引用
收藏
页码:488 / 492
页数:5
相关论文
共 50 条
  • [1] Reconstruction of complex orbital fracture with titanium implants
    Wen-Shu Yi 1
    International Journal of Ophthalmology, 2012, (04) : 488 - 492
  • [2] Use of bioresorbable implants for orbital fracture reconstruction
    Young, Stephanie M.
    Sundar, Gangadhara
    Lim, Thiam-Chye
    Lang, Stephanie S.
    Thomas, George
    Amrith, Shantha
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (08) : 1080 - 1085
  • [3] Use of Lorenz Titanium Implants in Orbital Fracture Repair
    Chang, Shu-Hong
    Custer, Philip L.
    Mohadjer, Yasaman
    Scott, Evan
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 25 (02): : 119 - 122
  • [4] Orbital Implants in Orbital Fracture Reconstruction: A Ten-Year Series
    Seen, Sophia
    Young, Stephanie
    Lang, Stephanie S.
    Lim, Thiam-Chye
    Amrith, Shantha
    Sundar, Gangadhara
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2021, 14 (01) : 56 - 63
  • [5] A Novel Patient-specific Titanium Mesh Implant Design for Reconstruction of Complex Orbital Fracture
    Kittichokechai, Pakaporn
    Sirichatchai, Kanin
    Puncreobutr, Chedtha
    Lohwongwatana, Boonrat
    Saonanon, Preamjit
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2022, 10 (01) : E4081
  • [6] Reconstruction of complex midfacial defects with individualized titanium implants
    Kokemueller, H.
    von See, C.
    Essig, H.
    Tavassol, F.
    Ruecker, M.
    Schramm, A.
    Majdani, O.
    Gellrich, N. -C.
    HNO, 2011, 59 (04) : 319 - 326
  • [7] Reconstruction of orbital blowout fractures using MEDPOR titanium mesh implants
    Han, Xiaohui
    Yang, Shunhai
    Dong, Zhizhang
    Feng, Wangqiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 12411 - 12415
  • [8] Orbital Bony Reconstruction With Presized and Precontoured Porous Polyethylene-Titanium Implants
    Blessing, Nathan W.
    Rong, Andrew J.
    Tse, Brian C.
    Erickson, Benjamin P.
    Lee, Bradford W.
    Johnson, Thomas E.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 37 (03): : 284 - 289
  • [9] Orbital implants for fracture repair
    Bratton, Emily M.
    Durairaj, Vikram D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (05) : 400 - 406
  • [10] Surgical Outcomes of Orbital Fracture Reconstruction Using Patient-Specific Implants
    Blumer, Michael
    Essig, Harald
    Steigmiller, Klaus
    Wagner, Maximilian Eberhard
    Gander, Thomas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (06) : 1302 - 1312