Performance evaluation of material and comparison of different temperature control strategies of a Guarded Hot Box U-value Test Facility

被引:13
|
作者
Basak, Chayan Kumar [1 ]
Sarkar, Gautam [2 ]
Neogi, Subhasis [1 ]
机构
[1] Jadavpur Univ, Sch Energy Studies, Kolkata 700032, India
[2] Jadavpur Univ, Dept Elect Engn, Kolkata 700032, India
关键词
U-value; On-off controller; PID; Pulse width modulation (PWM); Error indices; HVAC SYSTEM; COMFORT; DESIGN;
D O I
10.1016/j.enbuild.2015.07.050
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The overall energy consumption in a building could be minimized by controlling the heat gain or loss through its building components like walls, floors, roofs, window glazing etc. and for doing this, the thermal performance of the building materials should be evaluated. The U-value is one of the key measures of evaluating the thermal performance of any building material. The lesser the U-value, the less energy is required to maintain comfortable conditions inside the building. The U-value is measured using the Guarded Hot Box Test Facility. In the present work, two control strategies, one with a simple on-off and another with a Proportional-Integral-Derivative (PID) logic driven Pulse Width Modulation (PWM) technique, have been implemented, once with AC circulating fans and again with DC circulating fans inside the Guard box. Performance evaluation and comparison of them has been made in terms of three error indices viz, per unit time of Integral of Square Error (ISE); Integral of Absolute Error (IAE) and Integral of Time weighted Absolute Error (ITAE). From the experimental data obtained, it is found that the PID logic driven pulse width modulation technique with DC circulating fans installed inside the guard box shows the best temperature control profile. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 262
页数:5
相关论文
共 7 条
  • [1] Performance Evaluation of a Guarded Hot Box U-value Measurement Facility under Different Software Based Temperature Control Strategies
    Ghosh, Amrita
    Ghosh, Supratik
    Neogi, Subhasis
    4 INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER 2013), 2014, 54 : 448 - 454
  • [2] U-value assessment by infrared thermography: A comparison of different calculation methods in a Guarded Hot Box
    Nardi, Iole
    Paoletti, Domenica
    Ambrosini, Dario
    de Rubeis, Tullio
    Sfarra, Stefano
    ENERGY AND BUILDINGS, 2016, 122 : 211 - 221
  • [3] Performance Evaluation of a Guarded Hot Box Test Facility using Fuzzy Logic Controller for Different Building Material Samples
    Basak, Chayan Kumar
    Mitra, Debrudra
    Ghosh, Amrita
    Sarkar, Gautam
    Neogi, Subhasis
    5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER) 2015, 2016, 90 : 185 - 190
  • [4] U-VALUE TESTING OF WINDOWS USING A MODIFIED GUARDED HOT BOX TECHNIQUE
    RENNEKAMP, SJ
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (12): : 57 - 57
  • [5] Development of affordable hot box calorimeter to determine the U-value of inhomogeneous building material
    Alqahtani, Saad
    Ali, Hafiz Muhammad
    Ali, Hassan
    Farukh, Farukh
    Kandan, Karthikeyan
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 25 : 6492 - 6502
  • [6] Evaluation of supply air temperature control performance with different control strategies at air handling units
    Wang, Zufen
    Hashem, Marwan R.
    Song, Li
    Wang, Gang
    BUILDING AND ENVIRONMENT, 2023, 243
  • [7] Evaluation of energy efficient design strategies for different climatic zones: Comparison of thermal performance of buildings in temperate-humid and hot-dry climate
    Yilmaz, Z.
    ENERGY AND BUILDINGS, 2007, 39 (03) : 306 - 316