The power supply system for the DEPFET pixel detector at BELLE II

被引:9
|
作者
Rummel, Stefan [1 ]
机构
[1] Univ Munich, D-85748 Garching, Germany
关键词
BELLE II; DEPFET; APS; Vertex detector; Power supply; Power distribution; Electronics; Detector system;
D O I
10.1016/j.nima.2012.04.041
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The upgrade of the KEKB accelerator towards 8 x 10(35) cm(-2) s(-1) poses several challenges for the BELLE II detector. Especially the innermost detector will be faced with a significant radiation of several MRad per year as well as a high hit density. To cope with this a silicon pixel detector will be used for the inner layers of the silicon tracker. The pixel detector (PXD) consists of two layers of DEPFET active pixel sensors. The DEPFET technology has an unique set of advantages like low power dissipation in the active area, flexible device size, radiation hardness and a thinning procedure allowing to adjust the thickness of the device over a wide range. The two layers close to the interaction point together with a low material budget will improve the IP resolution by a factor of 2 compared to the previous installed silicon detector. In addition silicon stand-alone pattern recognition will be possible together with the four layers of double sided strip detectors (DSSD) of the strip detector. The PXD detector system consists of the DEPFET modules with integrated readout chips, the data handling hybrid receiving the data and sending them to compute nodes performing an online pattern recognition. Moreover the power supply system provides the supply voltages for the DEPFET from a position outside of the detector. The power distribution is designed to provide low output impedance over all frequencies and transient response with appropriate overshoots. The PXD pose several challenges to the power distribution system-number of voltages, tight requirements on regulation and noise. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 50 条
  • [1] The Belle II DEPFET pixel detector
    Luetticke, F.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [2] The Belle II DEPFET pixel detector
    Moser, Hans-Guenther
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 85 - 87
  • [3] DEPFET pixel detector in the Belle II experiment
    Abudinen, F.
    Ackermann, K.
    Ahlburg, P.
    Albalawi, M.
    Alonso, O.
    Andricek, L.
    Ayad, R.
    Babu, V
    Bai, Y.
    Bilka, T.
    Blanco, R.
    Boronat, M.
    Bozek, A.
    Camien, C.
    Caldwell, A.
    Chekelian, V
    Deschamps, B.
    Dieguez, A.
    Dingfelder, J.
    Dolezal, Z.
    Esperante, D.
    Fras, M.
    Frey, A.
    Fuster, J.
    Gabriel, M.
    Gadow, K.
    Gebauer, U.
    Germic, L.
    Gessler, T.
    Getzkow, D.
    Gioi, L.
    Gomis, P.
    Heck, M.
    Hemperek, T.
    Hensel, M.
    Hoek, M.
    Kandra, J.
    Kapusta, P.
    Kiesling, C.
    Kisielewski, B.
    Kittlinger, D.
    Klose, D.
    Kodys, P.
    Koffmane, C.
    Konorov, I
    Krivokuca, S.
    Krueger, H.
    Kuhr, T.
    Kuehn, W.
    Kvasnicka, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 657 - 659
  • [4] The ultralight DEPFET pixel detector of the Belle II experiment
    Luetticke, Florian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 118 - 121
  • [5] The DEPFET pixel detector for the Belle II experiment at SuperKEKB
    Kodys, P.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [6] Belle II pixel detector: Performance of final DEPFET modules
    Paschen, B.
    Abudinen, F.
    Ackermann, K.
    Ahlburg, P.
    Albalawi, M.
    Alonso, O.
    Andricek, L.
    Ayad, R.
    Babu, V.
    Bai, Y.
    Bilka, T.
    Blanco, R.
    Boronat, M.
    Bozek, A.
    Camien, C.
    Caldwell, A.
    Chekelian, V.
    Deschamps, B.
    Dieguez, A.
    Dingfelder, J.
    Dolezal, Z.
    Esperante, D.
    Fras, M.
    Frey, A.
    Fuster, J.
    Gabriel, M.
    Gadow, K.
    Gebauer, U.
    Germic, L.
    Gessler, T.
    Getzkow, D.
    Gioi, L.
    Gomis, P.
    Heck, M.
    Hemperek, T.
    Hensel, M.
    Hoek, M.
    Huber, S.
    Kandra, J.
    Kapusta, P.
    Kiesling, C.
    Kisielewski, B.
    Kittlinger, D.
    Klose, D.
    Kodys, P.
    Koffmane, C.
    Konorov, I.
    Krivokuca, S.
    Krueger, H.
    Kuhr, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 958
  • [7] DEPFET sensors development for the Pixel Detector (PXD) of Belle II
    Avella, P.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [8] DCDB and SWITCHERB, the Readout ASICs for Belle II DEPFET Pixel Detector
    Peric, Ivan
    Fischer, Peter
    Knopf, Jochen
    Thi Hong Hanh Nguyen
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1536 - 1539
  • [9] Gated Mode Operation of DEPFET Sensors for the Belle II Pixel Detector
    Valentan, Manfred
    Prinker, Eduard
    Mueller, Felix
    Koffmane, Christian
    Richter, Rainer
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [10] THE BELLE-II DEPFET PIXEL DETECTOR AT THE SUPERKEKB FLAVOUR FACTORY
    Heindl, Stefan
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 576 - 580