Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes

被引:6
|
作者
Rana, Zaker [1 ]
Nasr, Nadim M. [1 ]
Ji, Huaying [1 ]
Lorio, Virginia [1 ]
Akbari, Stephanie [1 ]
Sebastian, Molly [1 ]
Martin, Mami [1 ]
Hong, Robert L. [1 ]
机构
[1] Virginia Hosp Ctr, Dept Radiat Oncol, Arlington, VA 22205 USA
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
APBI; brachytherapy; Mammosite; Contura; Savi; MAMMOSITE BALLOON BRACHYTHERAPY; PHASE-II TRIAL; INTERSTITIAL BRACHYTHERAPY; TREATMENT EFFICACY; RADIATION-THERAPY; AMERICAN SOCIETY; REGISTRY TRIAL; LATE TOXICITY; FOLLOW-UP; CANCER;
D O I
10.1186/s13014-015-0468-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Accelerated partial breast irradiation (APBI) with balloon and strut adjusted volume implants (SAVI) show promising results with excellent tumor control and minimal toxicity. Knowing the factors that contribute to a high skin dose, rib dose, and D-95 coverage may reduce toxicity, improve tumor control, and help properly predict patient outcomes following APBI. Methods and materials: A retrospective analysis of 594 patients treated with brachytherapy based APBI at a single institution from May 2008 to September 2014 was grouped by applicator subtype. Patients were treated to a total of 34 Gy (3.4 Gy x 10 fractions over 5 days delivered BID) targeting a planning target volume (PTV) 1.0 cm beyond the lumpectomy cavity using a high dose rate source. Results: SAVI devices had the lowest statistically significant values of D(max)Skin (81.00 +/- 29.83), highest values of D-90 (101.50 +/- 3.66), and D-95 (96.09 +/- 4.55). SAVI-mini devices had the lowest statistically significant values of D(max)Rib (77.66 +/- 32.92) and smallest V-150 (18.01 +/- 3.39). Multi-lumen balloons were able to obtain the smallest V-200 (5.89 +/- 2.21). Strut-based applicators were more likely to achieve a D(max)Skin and a D(max)Rib less than or equal to 100 %. The effect of PTV on V-150 showed a strong positive relationship (p < .001). PTV and DmaxSkin showed a weak negative relationship in multi-lumen applicators (p = .016) and SAVI-mini devices (p < .001). PTV and DmaxRib showed a weak negative relationship in multi-lumen applicators (p = .009), SAVI devices (p < .001), and SAVI-mini devices (p < .001). Conclusion: PTV volume is strongly correlated with V-150 in all devices and V-200 in strut based devices. Larger PTV volumes result in greater V-150 and V-200, which could help predict potential risks for hotspots and resulting toxicities in these devices. PTV volume is also weakly negatively correlated with max skin dose and max rib dose, meaning that as the PTV volumes increase one can expect slightly smaller max skin and rib doses. Strut based applicators are significantly more effective in keeping skin and rib dose constraints under 125 and 100 % when compared to any balloon based applicator.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes
    Zaker Rana
    Nadim M. Nasr
    Huaying Ji
    Virginia Lorio
    Stephanie Akbari
    Molly Sebastian
    Mami Martin
    Robert L. Hong
    Radiation Oncology, 10
  • [2] A Contura™ catheter provides dosimetric advantages over a MammoSite™ catheter for accelerated partial breast irradiation
    Wilder, R. B.
    Mesa, A., V
    Chittenden, L.
    Curcio, L. D.
    Khanijou, R. K.
    Eisner, M. E.
    Ravera, J.
    Tokita, K. M.
    CANCER RESEARCH, 2009, 69 (02) : 342S - 342S
  • [3] IMPROVEMENTS IN CRITICAL DOSIMETRIC ENDPOINTS USING THE CONTURA MULTILUMEN BALLOON BREAST BRACHYTHERAPY CATHETER TO DELIVER ACCELERATED PARTIAL BREAST IRRADIATION: PRELIMINARY DOSIMETRIC FINDINGS OF A PHASE IV TRIAL
    Arthur, Douglas W.
    Vicini, Frank A.
    Todor, Dorin A.
    Julian, Thomas B.
    Lyden, Maureen R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01): : 26 - 33
  • [4] Dosimetric evaluation of accelerated partial breast irradiation using VMAT technique
    Peng, Jean L.
    McDonald, Dan G.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3529 - S3531
  • [5] Dosimetric investigation of accelerated partial breast irradiation (APBI) using CyberKnife
    Xu, Qianyi
    Chen, Yan
    Grimm, Jimm
    Fan, Jiajin
    An, Lili
    Xue, Jinyu
    Pahlajani, Niraj
    LaCouture, Tamara
    MEDICAL PHYSICS, 2012, 39 (11) : 6621 - 6628
  • [6] A Contura Catheter Offers Dosimetric Advantages over a MammoSite Catheter that Increase the Applicability of Accelerated Partial Breast Irradiation
    Mesa, A.
    Curcio, L. D.
    Khanijou, R. K.
    Eisner, M. E.
    Kakkis, J. L.
    Chittenden, L.
    Agustin, J.
    Lizarde, J.
    Tokita, K. M.
    Wilder, R. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S209 - S210
  • [7] A Contura catheter offers dosimetric advantages over a MammoSite catheter that increase the applicability of accelerated partial breast irradiation
    Wilder, Richard B.
    Curcio, Lisa D.
    Khanijou, Rajesh K.
    Eisner, Martin E.
    Kakkis, Jane L.
    Chittenden, Lucy
    Agustin, Jeffrey
    Lizarde, Jessica
    Mesa, Albert V.
    Ravera, John
    Tokita, Kenneth M.
    BRACHYTHERAPY, 2009, 8 (04) : 373 - 378
  • [8] Accelerated partial breast irradiation using proton beams: Initial dosimetric experience
    Taghian, Alphonse G.
    Kozak, Kevin R.
    Katz, Angela
    Adams, Judith
    Lu, Hsiao-Ming
    Powell, Simon N.
    DeLaney, Thomas F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (05): : 1404 - 1410
  • [9] Dosimetric Analysis of Partial Arcs for Accelerated Partial Breast Irradiation (APBI) Using Rapidarc Technique
    Nan, D.
    Rana, U.
    Padannayil, N. Manthala
    Alphonse, A.
    Pokharel, S.
    Demez, N.
    Leventouri, T.
    Pella, S.
    Rana, S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7791 - 7792
  • [10] Comparative Study Between Two Normalization Prescriptions for Accelerated Partial Breast Irradiation: A Dosimetric Study
    Agarwal, P.
    Sharma, D.
    Gandhi, A.
    Binjola, A.
    Subramani, V.
    Chander, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3368 - 3368