Partial discharge inception and degradation characteristics of inverter-fed motor sample under surge voltage condition

被引:0
|
作者
Morikawa, M [1 ]
Hayakawa, N [1 ]
Okubo, H [1 ]
机构
[1] Nagoya Univ, Dept Elect Engn & Comp Sci, Chikusa Ku, Nagoya, Aichi 4648603, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Surge voltages with the rise time of the order of nano-seconds may cause partial discharge (PD) and result in the degradation of electrical insulation performance of the inverter-fed motor coils. We investigated the PD inception and degradation characteristics of twisted pair samples under surge voltage condition. Experimental results firstly revealed that there existed no obvious correlation between PD inception voltage (PDIV) and the rise time of surge voltage. Secondly, PD propagation and degradation characteristics were also investigated under the higher voltage application, and discussed in terms of charge behavior in air gap and on enamel surface. Finally, we obtained the dependence of time leading to BD on enamel coating thickness of the wire.
引用
收藏
页码:426 / 429
页数:4
相关论文
共 50 条
  • [1] Partial discharge inception and propagation characteristics of magnet wire for inverter-fed motor under surge voltage application
    Hayakawa, Naok
    Morikawa, Masato
    Okubo, Hitoshi
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (01) : 39 - 45
  • [2] Partial discharge propagation and degradation characteristics of magnet wire for inverter-fed motor under surge voltage application
    Hayakawa, N.
    Inano, H.
    Inuzuka, K.
    Morikawa, M.
    Okubo, H.
    [J]. 2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 565 - 568
  • [3] Partial Discharge Inception Voltage for Magnet Wire of Inverter-fed Motors under Surge Voltage Application
    Hayakawa, Naoki
    Shimizu, Fuminobu
    Peng, Xie
    Okubo, Hitoshi
    [J]. 2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [4] Partial discharge characteristics of inverter-fed motor coil samples under AC and surge voltage conditions
    Hayakawa, N
    Okubo, H
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (01) : 5 - 10
  • [5] Partial discharge characteristics of inverter-fed motor coil samples under ac and surge voltage conditions
    Okubo, H
    Lu, YH
    Hayakawa, N
    [J]. 2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 589 - 592
  • [6] Partial discharge inception characteristics influenced by stressed wire length of inverter-fed motor
    Okubo, H
    Lu, Y
    Morikawa, M
    Hayakawa, N
    [J]. 2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 442 - 445
  • [7] Partial Discharge Inception Characteristics and Charge Behavior for Magnet Wire under Repetitive Inverter Surge Voltage Condition
    Shimizu, Fuminobu
    Nakamura, Yusuke
    Inano, Hiroshi
    Hayakawa, Naoki
    Okubo, Hitoshi
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 195 - 195
  • [8] Partial discharge characteristics of nanocomposite enameled wire for inverter-fed motor
    Inuzuka, K.
    Inano, H.
    Hayakawa, N.
    Hirose, T.
    Hamaguchi, M.
    Okubo, H.
    [J]. 2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 594 - 597
  • [9] Reduction Method of Fluctuation in Partial Discharge Inception Voltage for Inverter-Fed Rectangular Wire Motors
    Wakimoto, Toru
    Kojima, Hiroki
    Hayakawa, Naoki
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 2017, 198 (02) : 3 - 10
  • [10] Study of Partial Discharge Inception Voltage in Inverter Fed Electric Motor Insulation Systems
    Azpiazu, Leire Elorza
    Almandoz, Gaizka
    Egea, Aritz
    Ugalde, Gaizka
    Badiola, Xabier
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (04):