Validity of in vitro tests on aqueous spray pumps as surrogates for nasal deposition

被引:51
|
作者
Suman, JD
Laube, BL
Lin, TC
Brouet, G
Dalby, R
机构
[1] Univ Maryland, Dept Pharmaceut Sci, Baltimore, MD 21201 USA
[2] Johns Hopkins Sch Med, Dept Pediat, Baltimore, MD 21287 USA
[3] Valois Pharm, F-27100 Le Vaudreuil, France
关键词
deposition pattern; droplet size; nasal spray; plume geometry; regulatory; spray pattern;
D O I
10.1023/A:1013643912335
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. To determine whether deposition pattern is related to in vitro measurements of droplet size, plume geometry, and spray pattern between two different nasal spray pumps believed to have different performance characteristics. Methods. Ten healthy volunteers inhaled radiolabeled saline from two different spray pumps (pump A and pump B). Deposition pattern was quantified from lateral views of the nose by gamma scintigraphy, expressed as the ratio of anterior to posterior (I:O) and superior to inferior (U:L) deposition. Droplet size was determined by Malvern Mastersizer S. Spray patterns were determined at 2.5 and 5 cm from the tip of the spray nozzle. Two-dimensional images of the emitted plume were captured by high-speed still photography. Results. There were no significant differences in I:O or U:L ratios for pump A compared to pump B, indicating no significant differences in deposition pattern. The volume diameters, D-v10 and D-v50, were not statistically different for pump A compared to pump B. There was a significant difference in D-v90 between pump A and pump B, (86.9 +/- 5.8 mum and 77.4 +/- 2.4 mum, respectively; P < 0.001). The ratio of the longest to shortest diameter for the spray pattern with pump A was 1.26 +/- 0.06 at 2.5 cm and 1.44 +/- 0.08 at 5 cm. The ratio for pump B was 1.13 +/- 0.03 at 2.5 cm and 1.19 +/- 0.05 at 5 cm. Ratios at both heights were statistically different for pump A compared to pump B (P < 0.00002 and P < 0.000001, respectively) Plume geometry analysis indicated statistical differences in both the width (17.0 +/- 0.97 vs. 18.5 +/- 0.56 cm, respectively; p < 0.001) and the maximum length of the plumes (46.0 +/- 1.83 vs. 53.1 +/- 4.88 cm, respectively; p < .002). The differences in velocity of the plume and spray angle between the two pumps were not statistically different. Conclusions. Certain in vitro tests detected performance differences between the two pumps. However, these differences did not translate into different deposition patterns in vivo.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Validity of in Vitro Tests on Aqueous Spray Pumps as Surrogates for Nasal Deposition
    Julie D. Suman
    Beth L. Laube
    Ta-chun Lin
    Guillaume Brouet
    Richard Dalby
    Pharmaceutical Research, 2002, 19 : 1 - 6
  • [2] Validity of in vitro tests on aqueous spray pumps as surrogates for nasal deposition, absorption, and biologic response
    Suman, Julie D.
    Laube, Beth L.
    Dalby, Richard
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2006, 19 (04): : 510 - 521
  • [3] Characterization of nasal spray pumps and deposition pattern in a replica of the human nasal airway
    Cheng, YS
    Holmes, TD
    Gao, J
    Guilmette, RA
    Li, S
    Surakitbanharn, Y
    Rowlings, C
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (02): : 267 - 280
  • [4] HUMAN NASAL DEPOSITION OF MOMETASONE FUROATE AQUEOUS NASAL SPRAY
    Shah, S.
    Berger, R.
    Gupta, P.
    Monteith, D.
    McDermott, J.
    Connor, A.
    Li, W.
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2012, 109 (05) : A129 - A129
  • [5] Nasal deposition of ciclesonide nasal aerosol and mometasone aqueous nasal spray in allergic rhinitis patients
    Emanuel, Ivor A.
    Blaiss, Michael S.
    Meltzer, Eli O.
    Evans, Philip
    Connor, Alyson
    AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2014, 28 (02) : 117 - 121
  • [6] Comparison of Nasal Deposition and Clearance of Aerosol Generated by a Nebulizer and an Aqueous Spray Pump
    Julie D. Suman
    Beth L. Laube
    Richard Dalby
    Pharmaceutical Research, 1999, 16 : 1648 - 1652
  • [7] Comparison of nasal deposition and clearance of aerosol generated by a nebulizer and an aqueous spray pump
    Suman, JD
    Laube, BL
    Dalby, R
    PHARMACEUTICAL RESEARCH, 1999, 16 (10) : 1648 - 1652
  • [8] CLINICAL PATIENT NASAL DEPOSITION OF NONAQUEOUS BECLOMETHASONE SPRAY VERSUS AQUEOUS NASAL SPRAYS OF FLUTICASONE AND MOMETASONE
    Chand, Ramesh
    Kuehl, Philip J.
    McDonald, Jacob D.
    Leach, Chet
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (02) : A22 - A22
  • [9] CLINICALLY RELEVANT IN VITRO TESTS FOR THE ASSESSMENT OF INNOVATOR AND GENERIC NASAL SPRAY PRODUCTS
    Azimi, Mandana
    Longest, P. Worth
    Shur, Jag
    Price, Robert
    Hindle, Michael
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : A12 - A12
  • [10] Effect of Formulation- and Administration-Related Variables on Deposition Pattern of Nasal Spray Pumps Evaluated Using a Nasal Cast
    Vipra Kundoor
    Richard N. Dalby
    Pharmaceutical Research, 2011, 28 : 1895 - 1904