Development of a universal interface for the exchange of medical image data using magneto-optical media

被引:0
|
作者
Kaminsky, J
Rodt, T
Newe, A
Donnerstag, F
Zumkeller, M
机构
[1] Med Hochschule Hannover, Neurochirurg Klin, D-30625 Hannover, Germany
[2] Med Hochschule Hannover, Kliniken Neuroradiol, D-30625 Hannover, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2004年 / 49卷 / 1-2期
关键词
digital images; magneto-optical disc; DICOM; PACs; interface;
D O I
10.1515/BMT.2004.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Digital images generated by medical imaging form the basis for radiological diagnosis and surgical planning. Despite the advent of the DICOM 3.0 standard for medical image communication, widespread application of the existing information is often limited by incompatibility of the data formatting used by different equipment generations, and the manufacturer-specific standards employed. An exchange interface based on magneto optical discs has been developed to retrieve and present medical image data regardless of the technological hardware and the specific formats used. Specially adapted routines to retrieve the data first had to be developed. A modular program structure was used to allow flexibility in the implementation of further routines and other exchange media. Over 20,000 CT and MRI images including header information obtained from different General Electric and Siemens scanners were extracted successfully from MO discs. The image data were used for follow up and surgical planning and were transferred to a PAC-server. The interface proved reliable and easy to use. Support for further proprietary formats is currently being developed. The present exchange interface permits reliable retrieval of digital images for diagnostic and surgical planning purposes, regardless of the hardware generation and manufacturer-specific formats.
引用
收藏
页码:6 / 10
页数:5
相关论文
共 50 条
  • [1] Universal interface for exchange of medical images via magneto-optical discs
    Kaminsky, J
    Kischnik, B
    Graubner, G
    Newe, A
    Lotz, J
    Hussein, S
    Becker, H
    Samii, M
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (02) : 99 - 104
  • [2] Exchange of medical images via an universal magneto-optical disc interface.
    Kaminsky, J
    Newe, A
    Lotz, J
    Graubner, G
    Hussein, S
    Becker, H
    Samii, M
    [J]. CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 1061 - 1061
  • [3] Perpendicular magnetic recording using magneto-optical media
    Matsumoto, K
    [J]. FUJITSU SCIENTIFIC & TECHNICAL JOURNAL, 2001, 37 (02): : 155 - 163
  • [4] Magneto-optical data storage
    McDaniel, T
    [J]. COMMUNICATIONS OF THE ACM, 2000, 43 (11) : 56 - 63
  • [5] Interface wall energy in exchange-coupled magneto-optical recording films
    Hwang, WK
    Liu, JR
    Shieh, HPD
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5A): : 2715 - 2720
  • [6] New magneto-optical recording media
    Ferre, J
    [J]. MAGNETIC STORAGE SYSTEMS BEYOND 2000, 2001, 41 : 181 - 200
  • [7] ERASABLE MAGNETO-OPTICAL RECORDING MEDIA
    HARTMANN, M
    BRAAT, J
    JACOBS, B
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1984, 20 (05) : 1013 - 1018
  • [8] Image correction in magneto-optical microscopy
    Paturi, P
    Larsen, BH
    Jacobsen, BA
    Andersen, NH
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (06): : 2999 - 3001
  • [9] Image contrast in polarization microscopy of magneto-optical media through plastic substrates
    Hsieh, YC
    Mansuripur, M
    [J]. ODS - 1997 OPTICAL DATA STORAGE TOPICAL MEETING, CONFERENCE DIGEST, 1997, : 70 - 71
  • [10] MODELING MAGNETO-OPTICAL THIN-FILM MEDIA FOR OPTICAL-DATA STORAGE
    BALASUBRAMANIAN, K
    MARATHAY, AS
    MACLEOD, HA
    [J]. THIN SOLID FILMS, 1988, 164 : 391 - 403