X-Ray Diffraction and Differential Scanning Calorimetry Studies of Crystalline and Amorphous Regions in Composite Porous Films

被引:0
|
作者
Lazarev, S., I [1 ]
Golovin, Yu M. [1 ]
Polikarpov, V. M. [1 ]
Shestakov, K., V [1 ]
机构
[1] Tambov State Tech Univ, Tambov 392000, Russia
来源
JOURNAL OF SURFACE INVESTIGATION | 2019年 / 13卷 / 02期
关键词
radial distribution function; X-ray diffraction; differential scanning calorimetry; ESPA1 and MGA-95 composite polymer materials; ION-EXCHANGE MEMBRANES; ANTIFOULING PROPERTY; PERMEABILITY; SURFACE; SEM;
D O I
10.1134/S1027451019020125
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
A comparative analysis of the structural evolution of MGA-95 and ESPA1 polymer composite porous films is performed by plotting the radial distribution functions of atoms using empirical X-ray scattering intensity curves and the thermophysical parameters of melting are calculated using data from differential scanning calorimetry (DSC). In the case of the water-saturated MGA-95 sample, the atomic density in the first coordination sphere of the cellulose acetate macromolecule is shown to decrease due to the breaking of intramolecular hydrogen bonds. The atomic density of coordination spheres with radii corresponding to the lattice parameters decreased suggesting spatial disorder of the macromolecules. The DSC data for the MGA-95 film (the enthalpies of melting of the dry and water saturated samples are H = 8.57 and 6.55 J/g, respectively) suggests that sorption of water molecules leads to a decrease in the degree of crystallinity due to a change in the crystalline fractions in the polycrystals. In the case of the ESPA1 composite film, a decrease in the radius and an increase in the atomic density of the first coordination sphere are indicative of the orientational disorder of amorphous phase molecules upon the sorption of water. The appearance of additional coordination spheres with R-2 = 3.88 and R-3 = 5.26 angstrom in the swollen ESPA1 sample suggests the quantitative redistribution of crystal phases in the substrate material. A detailed analysis of endothermic peaks on the DSC curve shows that the ratio of low- and high-temperature phases varies from 64% : 36% in the dry sample up to 51% : 49% in the water saturated sample at almost identical enthalpies of melting of H = 12.18 and 11.66J/g, respectively.
引用
下载
收藏
页码:240 / 245
页数:6
相关论文
共 50 条
  • [1] X-Ray Diffraction and Differential Scanning Calorimetry Studies of Crystalline and Amorphous Regions in Composite Porous Films
    S. I. Lazarev
    Yu. M. Golovin
    V. M. Polikarpov
    K. V. Shestakov
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2019, 13 : 240 - 245
  • [2] Differential scanning calorimetry and X-ray diffraction studies of glycolipid membranes
    Ces, O
    Seddon, JM
    Templer, RH
    Mannock, DA
    McElhaney, RN
    BIOPHYSICAL CHEMISTRY: MEMBRANES AND PROTEINS, 2002, (283): : 267 - 276
  • [3] X-ray diffraction and differential scanning calorimetry studies of β′ → β transitions in fat mixtures
    Szydlowska-Czerniak, A
    Karlovits, G
    Lach, M
    Szlyk, E
    FOOD CHEMISTRY, 2005, 92 (01) : 133 - 141
  • [4] Use of Simultaneous X-ray Diffraction and Differential Scanning Calorimetry
    Pennartz, Paul
    Ferrara, Joseph D.
    Kishi, Akira
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2010, 66 : S130 - S130
  • [5] Simultaneous measurements of X-ray diffraction-differential scanning calorimetry
    Roque-Flores, Roxana Lili
    Matos, Jivaldo do Rosario
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 137 (04) : 1347 - 1358
  • [6] Simultaneous differential scanning calorimetry, X-ray diffraction and FTIR spectrometry in studies of ovalbumin denaturation
    Gorinstein, S.
    Zemser, M.
    Friedman, M.
    Chang, S.-M.
    International Journal of Peptide & Protein Research, 45 (03):
  • [7] STUDIES ON LECITHIN-CHOLESTEROL-WATER INTERACTIONS BY DIFFERENTIAL SCANNING CALORIMETRY AND X-RAY DIFFRACTION
    LADBROOK.BD
    WILLIAMS, RM
    CHAPMAN, D
    BIOCHIMICA ET BIOPHYSICA ACTA, 1968, 150 (03) : 333 - &
  • [8] Characterization of dimethyldiacyloxysilanes by differential scanning calorimetry, Raman scattering and X-ray diffraction
    Pallas, P
    Wartewig, S
    Zimmermann, I
    Richter, H
    PHARMAZIE, 2000, 55 (07): : 503 - 507
  • [9] X-ray diffraction and differential scanning calorimetry studies of a BaTiO3/polyvinylidene fluoride composites
    Elzayat, M. Y. F.
    El-Sayed, S.
    Osman, H. M.
    Amin, M.
    POLYMER ENGINEERING AND SCIENCE, 2012, 52 (09): : 1945 - 1950