50 kHz Capacitive Micromachined Ultrasonic Transducers for Generation of Highly Directional Sound with Parametric Arrays

被引:102
|
作者
Wygant, Ira O. [1 ]
Kupnik, Mario [1 ]
Windsor, Jeffry C. [2 ]
Wright, Wayne M. [2 ]
Wochner, Mark S. [2 ]
Yaralioglu, Goksen G. [1 ]
Hamilton, Mark F. [2 ]
Khuri-Yakub, Butrus T. [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
[2] Univ Texas Austin, Appl Res Labs, Austin, TX 78713 USA
基金
美国国家科学基金会;
关键词
AIR TRANSDUCERS; PVDF FILM; BEAMS; TRANSMITTERS; PERFORMANCE; FABRICATION; DESIGN; LEVEL; WAVES;
D O I
10.1109/TUFFC.2009.1019
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, we examine the use of capacitive micromachined ultrasonic transducers (CMUTs) with vacuum-sealed cavities for transmitting directional sound with parametric arrays. We used finite element modeling to design CMUTs with 40-mu m- and 60-mu m-thick membranes to have resonance frequencies of 46 kHz and 54 kHz, respectively. The wafer bonding approach used to fabricate the CMUTs provides good control over device properties and the capability to fabricate CMUTs with large diameter membranes and deep cavities. Each CMUT is 8 cm in diameter and consists of 284 Circular membranes. Each membrane is 4 mm in diameter. Characterization of the fabricated CMUTs shows they have center frequencies of 46 kHz and 55 kHz and 3 dB bandwidths of 1.9 kHz and 5.3 kHz for the 40-mu m- and 60-mu m-thick membrane devices, respectively. With dc bias voltages of 380 V and 350 V and an ac excitation of 200 V peak-to-peak, the CMUTs generate average sound pressure levels, normalized to the device's surface, of 1,35 dB and 129 dB (re 20 mu Pa), respectively. When used to generate 5 kHz sound with a parametric array, we measured sound at 3 m with a 6 dB beamwidth of 8.7 degrees and a sound pressure level of 58 dB. To understand how detector nonlinearity (e.g., the nonlinearity of the microphone used to make the sound level measurements) affects the measured sound pressure level, we made measurements with and without an acoustic low-pass filter placed in front of the microphone; the measured sound levels agree with numerical simulations of the pressure field. The results presented in this paper demonstrate that large-area CMUTs, which produce high-intensity ultrasound. can be fabricated for transmitting directional sound with parametric arrays.
引用
收藏
页码:193 / 203
页数:11
相关论文
共 50 条
  • [1] 50-kHz capacitive micromachined ultrasonic transducers for generating highly directional sound with parametric arrays
    Wygant, Ira O.
    Kupnik, Mario
    Yaralioglu, Goksen
    Khuri-Yakub, Butrus T.
    Windsor, Jeffry C.
    Wright, Wayne M.
    Wochner, Mark S.
    Hamilton, Mark F.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 519 - +
  • [2] Capacitive micromachined ultrasonic transducers:: Next-generation arrays for acoustic imaging?
    Oralkan, Ö
    Ergun, AS
    Johnson, JA
    Karaman, M
    Demirci, U
    Kaviani, K
    Lee, TH
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (11) : 1596 - 1610
  • [3] Directional scholte wave generation and detection using interdigital capacitive micromachined ultrasonic transducers
    McLean, J
    Degertekin, FL
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (06) : 756 - 764
  • [4] Singulation for imaging ring arrays of capacitive micromachined ultrasonic transducers
    Chang, Chienliu
    Moini, Azadeh
    Nikoozadeh, Amin
    Sarioglu, Ali Fatih
    Apte, Nikhil
    Zhuang, Xuefeng
    Khuri-Yakub, Butrus T.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (10)
  • [5] Broadband capacitive micromachined ultrasonic transducers ranging from 10 kHz to 60 mHz for imaging arrays and more
    Ergun, AS
    Huang, Y
    Cheng, CH
    Oralkan, Ö
    Johnson, J
    Jagannathan, H
    Demirci, U
    Yaralioglu, GG
    Karaman, M
    Khuri-Yakub, BT
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1039 - 1043
  • [6] Capacitive Micromachined Ultrasonic Transducers for forward looking intravascular imaging arrays
    Knight, JG
    Degertekin, FL
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1079 - 1082
  • [7] Response of capacitive micromachined ultrasonic transducers
    Ge Lifeng
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [8] Micromachined capacitive immersion ultrasonic transducers
    Khuri-Yakub, BT
    Jin, XC
    Ladabaum, I
    Degertekin, FL
    ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1998, 1998, 3341 : 237 - 241
  • [9] Advances in Capacitive Micromachined Ultrasonic Transducers
    Brenner, Kevin
    Ergun, Arif Sanli
    Firouzi, Kamyar
    Rasmussen, Morten Fischer
    Stedman, Quintin
    Khuri-Yakub, Butrus
    MICROMACHINES, 2019, 10 (02)
  • [10] Capacitive micromachined ultrasonic transducers and their application
    Buhrdorf, A
    Ahrens, O
    Binder, J
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 933 - 940