A reference material for harmonisation of D-dimer assays

被引:0
|
作者
Nieuwenhuizen, W
机构
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The term "D-dimer assay" suggests, that these assays report the concentrations of the end-stage degradation product of crosslinked fibrin. This hardly occurs in patients. Degradation products of cross linked fibrin rather occur with a wide range of molecular weights, and comprise various numbers of the D-dimer motif. Moreover, the numerical values obtained with different "D-dimer" assays vary widely. The variations are probably due to differences in reactivity of the various monoclonal antibodies used with the various D-dimer containing degradation products as they occur in patients; and to the various calibrators with a value assigned by the manufacturers. For the reasons indicated above a calibrator in the strict sense (e.g. pure D-dimer) is not feasible. This study shows that: it appears feasible to generate a conversion factor for each of the "D-dimer" assays studied? which will make the widely varying results obtained with these kits comparable; that the conversion factors can be based on a pool of real patient samples; and that the conversion factors are pool-independent. The next and final step in this study is to prepare and make available an international reference material for use by manufacturers and others facing a comparison problem. This is being carried out, in collaboration with the NIBSC (Dr. P. Gaffney), and the material is expected to, be available in early 1997.
引用
收藏
页码:1031 / 1033
页数:3
相关论文
共 50 条
  • [1] Harmonisation of D-dimer - A call for action
    Longstaff, Colin
    Adcock, Dorothy
    Olson, John D.
    Jennings, Ian
    Kitchen, Steve
    Mutch, Nicola
    Meijer, Piet
    Favaloro, Emmanuel J.
    Lippi, Giuseppe
    Thachil, Jecko
    [J]. THROMBOSIS RESEARCH, 2016, 137 : 219 - 220
  • [2] The reference ranges of D-dimer levels are different in pregnant women using various D-dimer assays
    Kessler, P.
    Petrik, R.
    Poul, H.
    Kusnierova, M.
    Horkay, G.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 592 - 592
  • [3] POOLED PATIENT SAMPLES AS REFERENCE MATERIAL FOR D-DIMER
    ADEMA, E
    GEBERT, U
    [J]. THROMBOSIS RESEARCH, 1995, 80 (01) : 85 - 88
  • [4] Comparison of the PATHFAST D-dimer assay with two POC D-dimer assays
    E Spanuth
    B Ivandic
    R Thomae
    E Giannitsis
    [J]. Critical Care, 19 (Suppl 1):
  • [5] Comparison of three D-dimer latex assays and a turbiquant D-dimer assay with FDP levels
    AlOmar, H
    Storbeck, M
    Garvey, B
    Freedman, J
    [J]. THROMBOSIS AND HAEMOSTASIS, 1997, : P1786 - P1786
  • [6] D-dimer assays for the exclusion of venous thromboembolism
    Reber, G
    de Moerloose, P
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2000, 26 (06): : 619 - 624
  • [7] D-dimer assays for the identification of menstrual blood
    Baker, David J.
    Grimes, Eileen A.
    Hopwood, Andrew J.
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2011, 212 (1-3) : 210 - 214
  • [8] A quality control for D-dimer assays.
    Ho, T
    Carrasco, L
    [J]. CLINICAL CHEMISTRY, 2002, 48 (06) : A160 - A161
  • [9] D-Dimer in normal pregnancy: determination of reference values for three commercially available assays
    Bergmann, Frauke
    Pingel, Nadine
    Czwalinna, Andreas
    Koch, Matthias
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (11) : E257 - E259
  • [10] IMPROVEMENT OF THE PERFORMANCE OF D-DIMER ASSAYS IN THE ELDERLY
    Haas, F. J. L. M.
    Schutgens, R. E. G.
    Biesma, D. H.
    [J]. HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 : 342 - 343