Measuring determination of U-values of external walls in comparison with typical catalogue values for existing buildings

被引:4
|
作者
Hoos, Thorsten [1 ]
Merzkirch, Alexander [1 ]
Maas, Stefan [1 ]
Scholzen, Frank [1 ]
Waldmann, Daniele [1 ]
机构
[1] Univ Luxemburg, Fak Nat Wissensch Technol & Kommunikat, Forsch Einheit Ingn Wissensch, L-1359 Luxembourg, Luxembourg
关键词
Heat flow density; Heat flow measurement; Hollow concrete block; Quarry stone external wall; Reconstruction;
D O I
10.1002/bapi.201510031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The economic benefit of retrofit actions for old buildings depends on possibly increasing building value and rents and also on the achieved energy savings. To estimate the savings, usually the calculated energy demand before and after the renovation is compared. Several studies show, that calculated energy demand and consumed energy often show great differences, especially for old buildings before the 1970s. One important input parameter for the energy demand calculation is the u-value of the facade which is commonly chosen by the energy expert on site, out of a catalogue, where typical values for certain wall constructions are presented. In this publication, results of heat flow measurements and dynamic simulations of different typical wall constructions of old buildings are presented. The measured and simulated u-values for those facades were between 0.9 and 1.2 W/(m(2)K) and significantly lower, than the values in the Luxembourgish catalogue, which range from 1.4 to 2.1 W/(m(2)K), depending on the construction material. The deviations between calculated building energy demand and actual consumed energy can at least partly be explained by false assumptions of energy experts on site, who use the u-value catalogue for choosing the input parameters of their calculation.
引用
收藏
页码:273 / 276
页数:4
相关论文
共 6 条
  • [1] Reassessing the Numerous Proposed and Existing U-values for Lebanon
    Saleh, Philip H.
    SECOND INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN: MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2016, : 30 - 37
  • [2] Hot box method to investigate U-values for straw bale walls with various structures
    Yang, Liu
    Yang, Jingjing
    Liu, Yan
    An, Yungang
    Chen, Jingheng
    ENERGY AND BUILDINGS, 2021, 234
  • [3] Thermal performance of 3D concrete printed walls: calculated and in-situ measured U-values
    Tamimi, Adil Al
    Hassan, Habibelrahman
    Rodriguez-Ubinas, Edwin
    Alhaidary, Haidar
    Mansouri, Abraham
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2024, 23 (06) : 1903 - 1915
  • [4] Climate Adapted Facades in Zero-Waste and Cradle to Cradle Buildings - Comparison, Evaluation and Future Recommendations, e.g. in Regard to U-Values, G-Values, Photovoltaic Integration, Thermal Performance and Solar Orientation
    Kader, Alexander
    5TH WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM (WMCAUS), 2020, 960
  • [5] Experimental and Numerical Study on the Dynamic Thermal Response of Building Interior Decoration Coatings during Intermittent Air-Conditioning in High U-Values Buildings in China
    Li, Yanru
    Chen, Yong
    Zhang, Lili
    Li, Xinyi
    ENERGIES, 2022, 15 (05)
  • [6] Determination of temperature differentials in thick pressure vessel walls from the chronological sequence of measured temperature values on the insulated external side of the wall
    Speitkamp, L.
    VGB-Kraftwerkstechnik, 1988, 68 (02): : 182 - 186