Fast beam monitor diamond-based devices for VUV and X-ray synchrotron radiation applications

被引:2
|
作者
Di Fraia, Michele [1 ]
De Sio, Antonio [2 ]
Antonelli, Matias [1 ]
Nesti, Renzo [3 ]
Panella, Dario [3 ]
Menk, Ralf H. [1 ]
Cautero, Giuseppe [1 ]
Coreno, Marcello [1 ,4 ]
Catone, Daniele [4 ]
Zema, Nicola [4 ]
Callegari, Carlo [1 ]
Pace, Emanuele [2 ]
机构
[1] Elettra Sincrotrone Trieste SCpA, Trieste, Italy
[2] Univ Firenze, Dipartimento Fis & Astron, Florence, Italy
[3] Osserv Astrofis Arcetri, Ist Nazl Astrofis, Florence, Italy
[4] CNR, Area Ric Roma Tor Vergata, ISM, Rome, Italy
关键词
CVD diamond; synchrotron; instrumentation; beam monitor; detectors; POSITION MONITOR; CVD DIAMOND; DETECTORS; BEAMLINES; HARD;
D O I
10.1107/S1600577519000791
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The improved performance of third-generation light sources and the advent of next-generation synchrotron radiation facilities require the use of extremely precise monitoring of the main photon-beam parameters, such as position, absolute and relative intensity, and temporal structure. These parameters, and associated real-time feedbacks, are fundamental at the beamline control level and at the machine control level, to improve the stability of the photon beams and to provide bunch-to-bunch quantitative information. Fast response time, high radiation hardness and visible-blind response are main features of photon-beam monitors for VUV and X-ray synchrotron radiation beamlines; hence diamond-based detectors are outstanding candidates. Here, results are presented of an extensive measurement campaign aiming at optimizing the capabilities of diamond detectors to discern time structures below the 100ps timescale. A custom-built device has been fabricated and tested at the Italian Synchrotron Radiation Laboratory Elettra in Trieste. The results obtained show that diamond is an excellent material for ultra-fast photon pulses with picosecond time resolution; finally the possibilities for application at free-electron laser sources are discussed.
引用
收藏
页码:386 / 392
页数:7
相关论文
共 50 条
  • [1] Fast beam monitor diamond-based devices for VUV and X-ray synchrotron radiation applications
    Di Fraia, Michele
    De Sio, Antonio
    Antonelli, Matias
    Nesti, Renzo
    Panella, Dario
    Menk, Ralf H.
    Cautero, Giuseppe
    Coreno, Marcello
    Catone, Daniele
    Zema, Nicola
    Callegari, Carlo
    Pace, Emanuele
    Journal of Synchrotron Radiation, 2019, 26 (02) : 386 - 392
  • [2] Diamond-based semi-transparent beam-position monitor for synchrotron radiation applications
    Bergonzo, P
    Brambilla, A
    Tromson, D
    Marshall, RD
    Jany, C
    Foulon, F
    Gauthier, C
    Solé, VA
    Rogalev, A
    Goulon, J
    JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1 - 5
  • [3] Diamond-based semi-transparent beam-position monitor for synchrotron radiation applications
    Bergonzo, P.
    Brambilla, A.
    Tromson, D.
    Marshall, R.D.
    Jany, C.
    Foulon, F.
    Gauthier, C.
    Sole, V.A.
    Rogalev, A.
    Goulon, J.
    Journal of Synchrotron Radiation, 1999, 6 (01): : 1 - 5
  • [4] Diamond detectors for synchrotron radiation X-ray applications
    De Sio, A.
    Pace, E.
    Cinque, G.
    Marcelli, A.
    Achard, J.
    Tallaire, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 558 - 561
  • [5] Characterization of beryllium and CVD diamond for synchrotron radiation beamline windows and x-ray beam monitor
    Goto, S.
    Takahashi, S.
    Kudo, T.
    Yabashi, M.
    Tamasaku, K.
    Nishino, Y.
    Ishikawa, T.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS II, 2007, 6705
  • [6] Synchrotron radiation x-ray beam profile monitor using chemical vapor deposition diamond film
    Kudo, Togo
    Takahashi, Sunao
    Nariyama, Nobuteru
    Hirono, Toko
    Tachibana, Takeshi
    Kitamura, Hideo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (12):
  • [7] A NEW BEAM POSITION MONITOR FOR X-RAY SYNCHROTRON RADIATION FACILITIES
    STEFAN, PM
    SIDDONS, DP
    HASTINGS, JB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (03): : 598 - 602
  • [8] An inexpensive spectroscopic beam monitor for hard X-ray synchrotron applications
    Owens, A.
    Andersson, S.
    Den Hartog, R.
    Quaratl, F.
    Webb, A.
    Welter, E.
    Journal of Instrumentation, 2007, 2
  • [9] An inexpensive spectroscopic beam monitor for hard X-ray synchrotron applications
    Owens, A.
    Andersson, S.
    den Hartog, R.
    Quarati, F.
    Webb, A.
    Welter, E.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [10] X-RAY, SOFT-X-RAY, AND VUV BEAM POSITION MONITOR
    KARLIN, BA
    COWAN, PL
    WOICIK, JC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 526 - 529