Evaluation of Electrical Capacitance Tomography Sensors for Concentric Annulus

被引:21
|
作者
Ye, Jiamin [1 ]
Yang, Wuqiang [2 ]
机构
[1] Univ Leeds, Sch Proc Environm & Mat Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Capacitance sensor; concentric annulus; electrical capacitance tomography (ECT); image reconstruction; internal-external electrode (IEE); IMAGE-RECONSTRUCTION ALGORITHMS; GAS-LIQUID; FLOW; SYSTEM; MODEL;
D O I
10.1109/JSEN.2012.2217955
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical capacitance tomography (ECT) sensor is commonly used with circular or square pipes or vessels. In this paper, an ECT sensor of concentric annulus shape is presented. To investigate the effect of the configuration of electrodes and the measuring strategy on the quality of reconstructed images, the ECT sensors with internal-external electrodes (IEE) and external electrodes (EE) are investigated. For the IEE sensor, six different measuring strategies are considered. The capacitance between different electrode pairs is calculated for some typical permittivity distributions using a finite element method (FEM). The obtained capacitance data are then used to reconstruct images using Landweber iteration algorithm. The sensitivity distributions for the IEE and EE sensors are analyzed. Simulation results show that the IEE sensor with 12 external electrodes and four internal electrodes combining with an external-opposite strategy can reconstruct good images for most permittivity distributions.
引用
收藏
页码:446 / 456
页数:11
相关论文
共 50 条
  • [1] Concentric-annulus electrical capacitance tomography sensors
    Ye, Jiamin
    Li, Yi
    Wang, Haigang
    Ge, Ruihuan
    Yang, Wuqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (09)
  • [2] Optimization of large scale concentric-annulus electrical capacitance tomography sensor with internal electrodes
    Liu, Zaixing
    Wang, Haigang
    Yang, Wuqiang
    Ge, Ruihuan
    MEASUREMENT, 2022, 188
  • [3] Design of electrical capacitance tomography sensors
    Yang, Wuqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (04)
  • [4] Simulation design of electrical capacitance tomography sensors
    Olmos, A. Martinez
    Primicia, J. Alberdi
    Marron, J. L. Fernandez
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2007, 1 (04) : 216 - 223
  • [5] An evaluation of the rotation of electrodes in multi-plane electrical capacitance tomography sensors
    Ye, Jiamin
    Mao, Mingxu
    Wang, Haigang
    Yang, Wuqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (12)
  • [6] Fringe effect of electrical capacitance and resistance tomography sensors
    Sun, Jiangtao
    Yang, Wuqiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (07)
  • [7] Characterization of Electrical Capacitance Tomography Sensors With Different Diameter
    Ye, Jiamin
    Wang, Haigang
    Yang, Wuqiang
    IEEE SENSORS JOURNAL, 2014, 14 (07) : 2240 - 2251
  • [8] Electrical Capacitance Tomography: Current Sensors/Algorithms and future Advances
    Neumayer, M.
    Steiner, G.
    Watzenig, D.
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 929 - 934
  • [9] OPTIMAL DESIGN AND FABRICATION STEPS OF ELECTRICAL CAPACITANCE TOMOGRAPHY SENSORS
    Ramanathan, Prabhu
    Arulmozhivarman, P.
    Tatavarti, Rao
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (03) : 301 - 310
  • [10] Evaluation of electrical resistance tomography with voltage excitation compared with electrical capacitance tomography
    Wang, Ruican
    Frias, Marco A. Rodriguez
    Wang, Haigang
    Yang, Wudiang
    Ye, Jiamin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (12)