Design and Simulation of an Integrated Centrifugal Microfluidic Device for CTCs Separation and Cell Lysis

被引:40
|
作者
Nasiri, Rohollah [1 ,2 ,3 ]
Shamloo, Amir [1 ]
Akbari, Javad [1 ]
Tebon, Peyton [2 ,3 ]
Dokmeci, Mehmet R. [2 ,3 ,4 ]
Ahadian, Samad [2 ,3 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, Tehran 1136511155, Iran
[2] Univ Calif Los Angeles, Ctr Minimally Invas Therapeut C MIT, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
关键词
microfluidics; circulating tumor cells; cell separation; micromixer; cell lysis; CIRCULATING TUMOR-CELLS; CLASSIFICATION; OPTIMIZATION; MICROMIXER; PARTICLES;
D O I
10.3390/mi11070699
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separation of circulating tumor cells (CTCs) from blood samples and subsequent DNA extraction from these cells play a crucial role in cancer research and drug discovery. Microfluidics is a versatile technology that has been applied to create niche solutions to biomedical applications, such as cell separation and mixing, droplet generation, bioprinting, and organs on a chip. Centrifugal microfluidic biochips created on compact disks show great potential in processing biological samples for point of care diagnostics. This study investigates the design and numerical simulation of an integrated microfluidic device, including a cell separation unit for isolating CTCs from a blood sample and a micromixer unit for cell lysis on a rotating disk platform. For this purpose, an inertial microfluidic device was designed for the separation of target cells by using contraction-expansion microchannel arrays. Additionally, a micromixer was incorporated to mix separated target cells with the cell lysis chemical reagent to dissolve their membranes to facilitate further assays. Our numerical simulation approach was validated for both cell separation and micromixer units and corroborates existing experimental results. In the first compartment of the proposed device (cell separation unit), several simulations were performed at different angular velocities from 500 rpm to 3000 rpm to find the optimum angular velocity for maximum separation efficiency. By using the proposed inertial separation approach, CTCs, were successfully separated from white blood cells (WBCs) with high efficiency (similar to 90%) at an angular velocity of 2000 rpm. Furthermore, a serpentine channel with rectangular obstacles was designed to achieve a highly efficient micromixer unit with high mixing quality (similar to 98%) for isolated CTCs lysis at 2000 rpm.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Computational study of an integrated microfluidic device for active separation of RBCs and cell lysis
    Jalilvand, Elahe
    Shamloo, Amir
    Gangaraj, Mojtaba Hassani
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2022, 174
  • [2] Design and simulation of a microfluidic device for acoustic cell separation
    Shamloo, Amir
    Boodaghi, Miad
    [J]. ULTRASONICS, 2018, 84 : 234 - 243
  • [3] Design of a Hybrid Inertial and Magnetophoretic Microfluidic Device for CTCs Separation from Blood
    Nasiri, Rohollah
    Shamloo, Amir
    Akbari, Javad
    [J]. MICROMACHINES, 2021, 12 (08)
  • [4] Continuous flow microfluidic device for cell separation, cell lysis and DNA purification
    Chen, Xing
    Cui, Dafu
    Liu, Changchun
    Li, Hui
    Chen, Jian
    [J]. ANALYTICA CHIMICA ACTA, 2007, 584 (02) : 237 - 243
  • [5] A centrifugal microfluidic device with integrated gold leaf electrodes for the electrophoretic separation of DNA
    Thompson, Brandon L.
    Birch, Christopher
    Nelson, Daniel A.
    Li, Jingyi
    DuVall, Jacquelyn A.
    Le Roux, Delphine
    Tsuei, An-Chi
    Mills, Daniel L.
    Root, Brian E.
    Landers, James P.
    [J]. LAB ON A CHIP, 2016, 16 (23) : 4569 - 4580
  • [6] SIMULATION OF AN INTEGRATED MICROFLUIDIC DEVICE FOR BIOPARTICLE WASH, SEPARATION AND CONCENTRATION
    Cetin, Barbaros
    Buyukkocak, Suleyman
    Zeinali, Soheila
    Ozer, Bulent
    [J]. PROCEEDINGS OF THE ASME 4TH INTERNATIONAL CONFERENCE ON MICRO/NANOSCALE HEAT AND MASS TRANSFER - 2013, 2014,
  • [7] A microfluidic electroporation device for cell lysis
    Lu, H
    Schmidt, MA
    Jensen, KF
    [J]. LAB ON A CHIP, 2005, 5 (01) : 23 - 29
  • [8] An Integrated Microfluidic Device for Rapid Cell Lysis and DNA Purification of Epithelial Cell Samples
    Ha, Seung-Mo
    Cho, Woong
    Ahn, Yoomin
    Hwang, Seung Yong
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (05) : 4250 - 4253
  • [9] A New Microfluidic Device for Electric Lysis and Separation of Cells
    Brun, M.
    Frenea-Robin, M.
    Chateaux, J. F.
    Haddour, N.
    Deman, A. L.
    Ferrigno, R.
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 6281 - 6284
  • [10] Design and verification of a blood cell separation microfluidic device
    Gawanmeh A.
    Alazzam A.
    Mathew B.
    [J]. 1600, Kassel University Press GmbH (13): : 105 - 112