Comparison of a single vs. a four intradermal sterile water injection for relief of lower back pain for women in labour: A randomised controlled trial

被引:22
|
作者
Lee, Nigel [1 ,4 ]
Webster, Joan [2 ,6 ]
Beckmann, Michael [3 ,5 ]
Gibbons, Kristen [3 ]
Smith, Tric [2 ]
Stapleton, Helen [1 ,4 ]
Kildea, Sue [1 ,4 ]
机构
[1] Mater Med Res Inst, Mater Hlth Serv, Midwifery Res Unit, South Brisbane, Qld 4101, Australia
[2] Royal Brisbane & Womens Hosp, Ctr Clin Nursing, Herston, Qld 4029, Australia
[3] Mater Med Res Inst, Mater Hlth Serv, South Brisbane, Qld 4101, Australia
[4] Australian Catholic Univ, Banyo, Qld 4014, Australia
[5] Mater Mothers Hosp, Mater Hlth Serv, South Brisbane, Qld 4101, Australia
[6] Griffith Univ, Sch Nursing & Midwifery, Brisbane, Qld 4111, Australia
关键词
Sterile water injection; Back pain in labour; Midwifery practice; Randomised controlled trial; INTRACUTANEOUS INJECTIONS; SCALE;
D O I
10.1016/j.midw.2012.05.001
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: sterile water injections are a simple, safe, effective, non-pharmacological technique for relieving back pain in labour, however the number of injections required to achieve optimal analgesia is unknown. The objective of this trial was to evaluate the degree and duration of analgesia provided by a single injection of sterile water, compared to four injections. Design: randomised controlled non-inferiority trial. Participants and setting: three hundred and five women in labour at term, requesting analgesia for back pain were recruited from two metropolitan hospitals in Brisbane, Australia. Intervention: participants were randomly assigned to receive either one (n=147) or four (n=158) sterile water injections. Outcome measures: difference in self-reported pain measured using a visual analogue scale (VAS) between baseline and 30 mins post-intervention. The clinically acceptable margin of difference was defined as <= 1 cm on the VAS between the single injection compared to four injection technique. Secondary outcomes include VAS score on injection and 10, 60, 90 and 120 mins post-intervention, analgesia use, mode of birth and maternal satisfaction. Findings: the mean difference in the pre and post (30 mins) injection scores between two groups was -1.48 cm (95% CI -2.10, -0.86) in favour of the FI technique, however the injection pain associated with the Fl was significantly greater than that of the SI technique (p < 0.001). There were no significant differences between the two groups in terms of other analgesic use, mode of birth or maternal satisfaction. Conclusion: the four injection technique was associated with increased level of analgesia at 30 mins post-intervention compared to the single injection, but also a greater degree of injection pain. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:585 / 591
页数:7
相关论文
共 40 条
  • [1] A randomised non-inferiority controlled trial of a single versus a four intradermal sterile water injection technique for relief of continuous lower back pain during labour
    Lee, Nigel
    Coxeter, Peter
    Beckmann, Michael
    Webster, Joan
    Wright, Vanessa
    Smith, Tric
    Kildea, Sue
    [J]. BMC PREGNANCY AND CHILDBIRTH, 2011, 11
  • [2] A randomised non-inferiority controlled trial of a single versus a four intradermal sterile water injection technique for relief of continuous lower back pain during labour
    Nigel Lee
    Peter Coxeter
    Michael Beckmann
    Joan Webster
    Vanessa Wright
    Tric Smith
    Sue Kildea
    [J]. BMC Pregnancy and Childbirth, 11
  • [3] A randomised controlled non-inferiority trial comparing a single and four Sterile Water Injection Technique for the relief of back pain during labour
    Lee, Nigel
    Kildea, Sue
    Coxeter, Peter
    Wright, Vanessa
    Beckmann, Michael
    Webster, Joan
    Smith, Patricia
    [J]. WOMEN AND BIRTH, 2011, 24 : S2 - S2
  • [4] Subcutaneous sterile water injection for labour pain: A randomised controlled trial
    Bahasadri, S
    Ahmadi-Abhari, S
    Dehghani-Nik, M
    Habibi, GR
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2006, 46 (02): : 102 - 106
  • [5] Correction: Sterile water injections for relief of labour pain (the SATURN trial): study protocol for a randomised controlled trial
    Nigel Lee
    Yu Gao
    Lena B. Mårtensson
    Leonie Callaway
    Belinda Barnett
    Sue Kildea
    [J]. Trials, 23
  • [6] Effectiveness of subcutaneous injection of sterile water to the lower back for pain relief in labor
    Kushtagi, Pralhad
    Bhanu, Basvanahalli Thimmegouda
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2009, 88 (02) : 231 - 233
  • [7] INTRACUTANEOUS STERILE WATER INJECTION OVER SACRUM FOR THE RELIEF OF LOW BACK PAIN IN LABOUR
    Valarmathy, S.
    Hema, J. Josephine
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (28): : 3151 - 3154
  • [8] Labour pain treated with cutaneous injections of sterile water:: a randomised controlled trial
    Mårtensson, L
    Wallin, G
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1999, 106 (07): : 633 - 637
  • [9] Effects of Intradermal Sterile Water Injections in Women with Low Back Pain in Labor: A Randomized, Controlled, Clinical Trial
    Koyucu, Refika Genc
    Demirci, Nurdan
    Yumru, Ayse Ender
    Salman, Suleyman
    Ayanoglu, Yavuz Tahsin
    Tosun, Yildiz
    Tayfur, Cihangir
    [J]. BALKAN MEDICAL JOURNAL, 2018, 35 (02) : 148 - 154
  • [10] Sterile water injections for relief of labour pain (the SATURN trial): study protocol for a randomised controlled trial (vol 23, 155, 2022)
    Lee, Nigel
    Gao, Yu
    Martensson, Lena B.
    Callaway, Leonie
    Barnett, Belinda
    Kildea, Sue
    [J]. TRIALS, 2022, 23 (01)