Equivalent Inertial Force Method of Seismic Calculation for Subway Station in Soft Site

被引:1
|
作者
Wang, Guofu [1 ]
Shang, Jinhua [1 ]
Ma, Xianfeng [2 ]
Xu, Xiyong [1 ]
机构
[1] Jinan Rail Transit Grp Co Ltd, Jinan 250000, Peoples R China
[2] Tongji Univ, Dept Geotech Engn, Shanghai 200092, Peoples R China
关键词
D O I
10.1155/2016/4751071
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
On the basis of the structural characteristics of subway stations, structural inertial force can be simplified as multiple concentrated force acting on the member connecting node by using equivalent inertial force method of seismic calculation in soft site, and then internal forces of the structure will be analyzed. According to the principle that the maximum bending moment values of equivalent inertial force method and dynamic time-history analysis method are equal and the location is the same, the value of equivalent inertial force is determined, and the shear and axial force are ensured by introducing correction factor. The result shows that the calculation results of equivalent inertial force method are accurate and reliable. It can meet the design requirements and improve computational efficiency.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Influence of ground structure on the seismic response of underground subway station in soft site
    Long, Hui
    Chen, Guoxing
    Zhuang, Haiyang
    [J]. ADVANCES IN CIVIL ENGINEERING AND ARCHITECTURE INNOVATION, PTS 1-6, 2012, 368-373 : 2769 - 2775
  • [2] Analysis of Equivalent Static Method for Subway Station
    Chen, Liang
    Yang, Dejian
    [J]. ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 1382 - 1386
  • [3] Analysis of seismic response influence of high rise building nearby subway station in soft site
    Long, Hui
    Chen, Guoxing
    Zhuang, Haiyang
    [J]. PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 2105 - 2111
  • [4] Response Displacement Method for Seismic Calculation of Subway Station Complex Structure of TOD Mode
    An, Junhai
    Feng, Fuqiang
    Zhang, Yanhua
    Li, Ming
    [J]. BUILDINGS, 2023, 13 (12)
  • [5] Experimental Study on the Seismic Response of Subway Station in Soft Ground
    Ma Xianfeng
    Wang Guobo
    Wu Jun
    Ji Qianqian
    [J]. JOURNAL OF EARTHQUAKE AND TSUNAMI, 2017, 11 (05)
  • [6] Investigations of seismic response to an irregular-section subway station structure located in a soft clay site
    Tang, Baizan
    Li, Xiaojun
    Chen, Su
    Zhuang, Haiyang
    Chen, Hua-Peng
    [J]. ENGINEERING STRUCTURES, 2020, 217
  • [7] Seismic responses of subway station with different distributions of soft soil in Tianjin
    Yang D.
    Duan M.
    [J]. Frontiers of Structural and Civil Engineering, 2014, 8 (2) : 187 - 193
  • [8] Seismic Response Analysis of Subway Station in Tianjin Soft Soil Area
    Yang, Dejian
    Li, Ya
    [J]. PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 2171 - 2176
  • [9] Seismic responses of a complicated subway underground station in soft soil layers
    Wang J.
    Zhuang H.
    Ma G.
    Yu X.
    Dou Y.
    Li J.
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (19): : 115 - 122and160
  • [10] Effect of soft layer on seismic response of subway station in layered stratum
    Li, Yayong
    Jin, Xiaoguang
    Feng, Yuansheng
    Luo, Wei
    [J]. JOURNAL OF VIBROENGINEERING, 2016, 18 (03) : 1602 - 1616