Non-enzymatic glucose sensing on copper-nickel thin film alloy

被引:21
|
作者
Poetzelberger, Isabella [1 ]
Mardare, Andrei Ionut [1 ,2 ]
Hassel, Achim Walter [1 ,2 ]
机构
[1] Johannes Kepler Univ Linz, Inst Chem Technol Inorgan Mat, Altenberger Str 69, A-4040 Linz, Austria
[2] Johannes Kepler Univ Linz, Christian Doppler Lab Combinatorial Oxide Chem, Inst Chem Technol Inorgan Mat, Altenberger Str 69, A-4040 Linz, Austria
关键词
Glucose; Electrocatalytic oxidation; Flow type scanning droplet cell microscopy; Copper nickel alloys; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; NANOHYBRID FILMS; ALKALINE MEDIA; SENSOR; NANOPARTICLES; ELECTROOXIDATION; FABRICATION; BIOSENSORS; GRAPHENE;
D O I
10.1016/j.apsusc.2016.12.193
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A simple and cost efficient glucose sensor was constructed using 3D printing having as active material a copper-15 at.% nickel thin film thermally co-evaporated on copper plated circuit boards. The glucose detection in alkaline solution was studied in detail by cyclic voltammetric and chronoamperometric measurements. The sensor suitability for being used in both quantitative and qualitative glucose detection was demonstrated and calibration of its response to various amounts of glucose revealed two linear regimes with different sensitivities. Glucose levels between 0 and 10 mM are most efficiently quantified as indicated by an amperometric signal increase of 240 mu Acm(-2) for each 1 mM increase of glucose concentration. The potentiostatic stability of the sensor was evaluated and its complete insensitivity after 7 h was solely attributed to the irreversible transformation of glucose into gluconolactone. A sensor life time of 20 cycles was demonstrated during potentiodynamic cycling when the sensor response remains constant at its maximum level. The magnitude of possible glucose quantification errors were evaluated as interferences induced by additions of ascorbic and uric acids. A worst case scenario of 96 % accuracy of glucose levels quantification was demonstrated using 25 times higher concentrations of interfering substances as compared to the glucose level. (C) 2016 Elsevier B. V. All rights reserved.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [1] Copper-nickel oxide nanofilm modified electrode for non-enzymatic determination of glucose
    Hasanzadeh, Mahsa
    Hasanzadeh, Zahra
    Alizadeh, Sakineh
    Sayadi, Mehran
    Nezhad, Mojtaba Nasiri
    Sabzi, Reza E.
    Ahmadi, Sajjad
    [J]. JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2020, 10 (03): : 245 - 255
  • [2] Incorporation of nickel particles into a polyaniline thin film for non-enzymatic glucose sensing in alkaline medium
    Belgherbi, Ouafia
    Messoudi, Meriem
    Bezi, Hamza
    Seid, Lamria
    Chouder, Dalila
    Lamiri, Leila
    Tounsi, Assia
    Akhtar, M. Saeed
    Saeed, M. A.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (04) : 851 - 863
  • [3] Dendritic core-shell copper-nickel alloy@metal oxide for efficient non-enzymatic glucose detection
    Wei, Huige
    Xu, Qizhou
    Li, Ang
    Wan, Tong
    Huang, Yan
    Cui, Dapeng
    Pan, Duo
    Dong, Binbin
    Wei, Renbo
    Naik, Nithesh
    Guo, Zhanhu
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 337
  • [4] A Non-enzymatic Glucose Sensor Based on Graphene Modified Copper-Nickel Bimetallic Dendrite Structure
    Ren, Zhaodi
    Cao, Lei
    Guo, Qihao
    Dong, Rui
    Zhong, Shengquan
    Sun, Xiaoliang
    Liu, Yuanan
    [J]. CHEMISTRYSELECT, 2022, 7 (41):
  • [5] Porous Copper Oxide Thin Film Electrodes for Non-Enzymatic Glucose Detection
    Carinelli, Soledad
    Salazar-Carballo, Pedro A.
    Melian, Julio Ernesto De la Rosa
    Garcia-Garcia, Francisco
    [J]. CHEMOSENSORS, 2023, 11 (05)
  • [6] Glucose sensing characterization of non-enzymatic nickel film and nickel foam electrodes in sodium hydroxide solution
    Tekacharin, Parit
    Chobaomsup, Viriyah
    Kamchaddaskorn, Atthadej
    Jongprateep, Oratai
    Saisriyoot, Maythee
    Surawathanawises, Krissada
    Boonyongmaneerat, Yuttanant
    Techapiesancharoenkij, Ratchatee
    [J]. SIAM PHYSICS CONGRESS 2018 (SPC2018): A CREATIVE PATH TO SUSTAINABLE INNOVATION, 2018, 1144
  • [7] Non-Enzymatic Detection of Glucose in Neutral Solution Using PBS-Treated Electrodeposited Copper-Nickel Electrodes
    Goodnight, Lindsey
    Butler, Derrick
    Xia, Tunan
    Ebrahimi, Aida
    [J]. BIOSENSORS-BASEL, 2021, 11 (11):
  • [8] Synthesis of copper nanorods for non-enzymatic amperometric sensing of glucose
    Xiangjian Liu
    Wenxiu Yang
    Lulu Chen
    Jianbo Jia
    [J]. Microchimica Acta, 2016, 183 : 2369 - 2375
  • [9] Synthesis of copper nanorods for non-enzymatic amperometric sensing of glucose
    Liu, Xiangjian
    Yang, Wenxiu
    Chen, Lulu
    Jia, Jianbo
    [J]. MICROCHIMICA ACTA, 2016, 183 (08) : 2369 - 2375
  • [10] Copper/reduced graphene oxide film modified electrode for non-enzymatic glucose sensing application
    Phetsang, Sopit
    Kidkhunthod, Pinit
    Chanlek, Narong
    Jakmunee, Jaroon
    Mungkornasawakul, Pitchaya
    Ounnunkad, Kontad
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)