Fabrication and high acoustic performance of high frequency needle ultrasound transducer with PMN-PT/Epoxy 1-3 piezoelectric composite prepared by dice and fill method

被引:33
|
作者
Wang, Jushan [1 ]
Chen, Mingzhu [1 ]
Zhao, Xiangyong [1 ]
Wang, Feifei [1 ]
Tang, Yanxue [1 ]
Lin, Di [2 ]
Luo, Haosu [2 ]
机构
[1] Shanghai Normal Univ, Dept Phys, Key Lab Optoelect Mat & Device, Shanghai 200234, Peoples R China
[2] Univ Chinese Acad Sci, Shanghai Inst Ceram, Key Lab Inorgan Funct Mat & Devices, 215 ChengbeiRd, Shanghai 201800, Peoples R China
基金
中国国家自然科学基金;
关键词
Dice and fill; PMN-PT/Epoxy 1-3 piezoelectric composite; Thickness extension mode; Acoustic performance; High frequency and high performance; ultrasound transducer; PT SINGLE-CRYSTAL; DESIGN; MHZ;
D O I
10.1016/j.sna.2020.112528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we reported the fabrication and high acoustic performance of high frequency needle ultrasound transducer based on 0.70Pb(Mg1/3Nb2/3)O-3-0.30PbTiO(3) single crystal/Epoxy 1-3 piezoelectric composite, which was prepared by using the dice and fill (DAF) method. The as-prepared 0.70PMN-0.30 PT/Epoxy 1-3 composite has high thickness extension mode electromechanical coupling coefficient with the value of 67.3 %. The transducer is designed by PMN-PT/Epoxy 1-3 piezoelectric composite with a dimension of 550 mu m x 450 mu m x 35 mu m. The fabricated transducer has not only a high center frequency larger than 42 MHz, but also high bandwidth of-6 dB of 90.6 %, the insertion loss with the value of 16 dB and excellent transmitting sensitivity of 314 mV/V. The results are in good agreement with the values simulated by PiezoCAD software. In addition, the acoustic performance of the transducer was also obtained by measuring the acoustic filed distribution in purified water. The-3 dB acoustic beam dimension width, the value of focal length and the acoustic power were 0.38 mm x 0.42 mm, 2.3 mm and 4.4 x 10(-3)mW, respectively. The performance PMN-PT/Epoxy 1-3 piezoelectric composite ultrasound transducer fabricated by dice and fill method (DAF) achieved the effect of ultrasonic transducer fabricated by deep reactive ion etching (DRIE). The excellent acoustic performance demonstrated that the DAF prepared PMN-PT/Epoxy 1-3 piezoelectric composite have great industry application potential in high frequency ultrasonic electronics, such as microelectronics NDT and biomedical imaging. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Cold ablated high frequency PMN-PT/Epoxy 1-3 composite transducer
    Lv, Jiabing
    Xie, Xu
    Zhu, Xinle
    Li, Zhangjian
    Han, Zhile
    Cui, Yaoyao
    Zhang, Bo
    Jian, Xiaohua
    APPLIED ACOUSTICS, 2022, 188
  • [2] High Frequency PMN-PT 1-3 Composite Transducer for Ultrasonic Imaging Application
    Sun, Ping
    Wang, Gaofeng
    Wu, Dawei
    Zhu, Benpeng
    Hu, Changhong
    Liu, Changgeng
    Djuth, Frank T.
    Zhou, Qifa
    Shung, K. Kirk
    FERROELECTRICS, 2010, 408 : 120 - 128
  • [3] Micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular array
    Liu, Changgeng
    Djuth, Frank
    Li, Xiang
    Chen, Ruimin
    Zhou, Qifa
    Kirk Shung, K.
    Ultrasonics, 2012, 52 (04): : 497 - 502
  • [4] Micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular array
    Liu, Changgeng
    Djuth, Frank
    Li, Xiang
    Chen, Ruimin
    Zhou, Qifa
    Shung, K. Kirk
    ULTRASONICS, 2012, 52 (04) : 497 - 502
  • [5] Micromachined High Frequency PMN-PT 1-3 Composite Transducer via Cold Ablation Process
    Lv, Jiabing
    Li, Zhangjian
    Cui, Yaoyao
    Jian, Xiaohua
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [6] High-Performance PMN-PT Single-Crystal-Based 1-3 Composite Transducer Integrated with a Biopsy Needle
    Kreager, Benjamin C.
    Wu, Huaiyu
    Chang, Wei-Yi
    Moon, Sunho
    Mitchell, Josh
    Peng, Chang
    Huang, Chih-Chung
    Muller, Marie
    Tian, Jian
    Jiang, Xiaoning
    BIOSENSORS-BASEL, 2024, 14 (02):
  • [7] Fabrication and Performance of Endoscopic Ultrasound Radial Arrays Based on PMN-PT Single Crystal/Epoxy 1-3 Composite
    Zhou, Dan
    Cheung, Kwok Fung
    Chen, Yan
    Lau, Sien Ting
    Zhou, Qifa
    Shung, K. Kirk
    Luo, Hao Su
    Dai, Jiyan
    Chan, Helen Lai Wa
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (02) : 477 - 484
  • [8] Micromachining of High-Quality PMN-PT/Epoxy 1-3 Composite for High-Frequency (>30 MHz) Ultrasonic Transducer Applications
    Lei, Zhihong
    Xu, Guisheng
    Liu, Jinfeng
    Liu, Youjian
    Ji, Xuanrong
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (11) : 1563 - 1573
  • [9] PMN-PT/Epoxy 1-3 composite based ultrasonic transducer for dual-modality photoacoustic and ultrasound endoscopy
    Li, Yan
    Lu, Gengxi
    Chen, Jason J.
    Jing, Joseph C.
    Huo, Tiancheng
    Chen, Ruimin
    Jiang, Laiming
    Zhou, Qifa
    Chen, Zhongping
    PHOTOACOUSTICS, 2019, 15
  • [10] A Dual-layer Micromachined PMN-PT 1-3 Composite Transducer for Broadband Ultrasound Imaging
    Li, Sibo
    Huang, Wenbin
    Jiang, Xiaoning
    Jian, Xiaohua
    Cui, Yaoyao
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 773 - 776