Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm

被引:12
|
作者
Stathakis, Sotirios [1 ]
Esquivel, Carlos [1 ]
Gutierrez, Alonso N. [1 ]
Shi, ChengYu [1 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Radiat Oncol, San Antonio, TX 78229 USA
关键词
Spatially fractionated radiation therapy; Grid therapy; Collapsed cone convolution superposition; GRID THERAPY; FILM; IRRADIATION; ADVANTAGE; CANCERS; PHOTON;
D O I
10.1016/j.apradiso.2009.06.012
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle(3) treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater (R) phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle(3) predicted dose distributions and the measurements for the majority of experiments performed. A higher magnitude of discrepancy (15%) was observed using a high photon beam energy (18 MV) and small GRID opening. Skin dose at the GRID openings was higher than the corresponding open field by a factor as high as three for both photon energies and was found to be independent of the open-to-blocked area ratio. Conclusion: In summary, we reaffirm that the MLC can be used to deliver spatially fractionated GRID therapy and show that various GRID patterns may be generated. The Pinnacle(3) TPS can accurately calculate the dose of the different GRID patterns in our study to within 5% for the majority of the cases based on film and ion chamber measurements. Disadvantages of MLC-based GRID therapy are longer treatment times and higher surface doses. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1939 / 1944
页数:6
相关论文
共 18 条
  • [1] A Novel Approach to Delivering Multi-Leaf Collimator Based Spatially Fractionated Radiation Therapy
    Maloney, K.
    Cardarelli, G.
    Klein, E.
    Schwer, M.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E684 - E684
  • [2] Dosimetric Effect of Multi-Leaf Collimator Transmission On Intensity-Modulated Radiation Therapy
    Yang, R.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Novel Monte Carlo dose calculation algorithm for robotic radiosurgery with multi leaf collimator: Dosimetric evaluation
    Heidorn, Sarah-Charlotta
    Kilby, Warren
    Fuerweger, Christoph
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 55 : 25 - 32
  • [4] Dose-based optimisation for multi-leaf collimator tracking during radiation therapy
    Mejnertsen, Lars
    Hewson, Emily
    Nguyen, Doan Trang
    Booth, Jeremy
    Keall, Paul
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [5] Evaluation and Validation of a Set of Dosimetric and Geometric Accuracy Tests of the Collapsed Cone Convolution Superposition Dose Calculation Algorithm for the RefleXion Treatment Planning System
    Bassalow, R.
    Zaks, D.
    Maganti, S.
    Voronenko, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E159 - E159
  • [6] Dosimetric evaluation of MRI-guided multi-leaf collimator tracking and trailing for lung stereotactic body radiation therapy
    Uijtewaal, Prescilla
    Borman, Pim T. S.
    Woodhead, Peter L.
    Hackett, Sara L.
    Raaymakers, Bas W.
    Fast, Martin F.
    [J]. MEDICAL PHYSICS, 2021, 48 (04) : 1520 - 1532
  • [7] Modulated electron radiation therapy using a conventional multi-leaf collimator: A feasibility study
    Ding, M
    Li, J
    Price, R
    Paskalev, K
    McNeedey, SW
    Qin, L
    Xiong, W
    Ma, C
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1447 - 1447
  • [8] A software approach to speed up collapsed cone convolution superposition dose calculation on multi-processor personal computers
    Corbit, C.
    Narayanan, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2411 - 2411
  • [9] Evaluation of dosimetric effect caused by slowing with multi-leaf collimator (MLC) leaves for volumetric modulated arc therapy (VMAT)
    Xu, Zhengzheng
    Wang, Iris Z.
    Kumaraswamy, Lalith K.
    Podgorsak, Matthew B.
    [J]. RADIOLOGY AND ONCOLOGY, 2016, 50 (01) : 121 - 128
  • [10] Discrepancy of Intensity Modulation Radiation Therapy Dose Delivery due to the Dose-Dynamic Multi-Leaf Collimator Gravity Effect
    Lee, Jeong-Woo
    Chung, Jin-Beom
    Lee, Doo-Hyun
    Park, Jeong-Hoon
    Choe, Bo-Young
    Suh, Tae-Suk
    Jang, Hong-Seok
    Hong, Semie
    Park, Byung-Moon
    Kang, Min-Young
    Choi, Kyoung-Sik
    Kim, You-Hyun
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 53 (06) : 3436 - 3443