Towards fast and robust 4D optimization for moving tumors with scanned proton therapy

被引:17
|
作者
Buti, Gregory [1 ]
Souris, Kevin [1 ]
Montero, Ana Maria Barragan [1 ]
Lee, John Aldo [1 ]
Sterpin, Edmond [1 ,2 ]
机构
[1] Catholic Univ Louvain, Ctr Mol Imaging Radiotherapy & Oncol MIRO, IREC, B-1200 Brussels, Belgium
[2] Katholieke Univ Leuven, Lab Expt Radiotherapy, Dept Oncol, B-3000 Leuven, Belgium
关键词
lung tumors; proton therapy; robust optimization; RANGE UNCERTAINTIES; LUNG-CANCER; MONTE-CARLO; OROPHARYNGEAL CANCER; TREATMENT PLANS; MOTION; SETUP; INTERPLAY; SENSITIVITY; IMPACT;
D O I
10.1002/mp.13850
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Robust optimization is becoming the gold standard for generating robust plans against various kinds of treatment uncertainties. Today, most robust optimization strategies use a pragmatic set of treatment scenarios (the so-called uncertainty set) consisting of combinations of maximum errors, of each considered uncertainty source (such as tumor motion, setup and image-conversion errors). This approach presents two key issues. First, a subset of considered scenarios is unnecessarily improbable which could potentially compromise the plan quality. Second, the resulting large uncertainty set leads to long plan computation times, which limits the potential for robust optimization as a standard clinical tool. In order to address these issues, a method is introduced which is able to preselect a limited set of relevant treatment error scenarios. Methods Uncertainties due to systematic setup errors, image-conversion errors and respiratory tumor motion are considered. A four-dimensional (4D)-equiprobability hypersurface is defined, which takes into account the joint probabilities of the above-mentioned uncertainty sources. Only scenarios that lie on the predefined 4D hypersurface are considered, guaranteeing statistical consistency of the uncertainty set. In this regard, twelve scenarios are selected that cover maximum spatial displacements of the tumor during breathing. Subsequently, additional scenarios are considered (sampled from the aforementioned 4D hypersurface) in order to cover any estimated residual range errors. Two different scenario-selection procedures were tested: (a) the maximum displacements (MD) method that only considers twelve scaled maximum displacement scenarios and (b) maximum displacements and residual range (MDR) method which, in addition to the scaled maximum displacement scenarios, considers additional maximum range uncertainty scenarios. The methods were tested for five lung cancer patients by performing comprehensive Monte Carlo robustness evaluations. Results A plan computation time gain of 78% is achieved by applying the MD method, whilst obtaining a target robustness of D95 larger than 95% of the prescribed dose, for the worst-case scenario. Additionally, the MD method has the potential to be fully automatic which makes it a promising candidate for fast automatic planning workflows. The MDR method produced plans with excellent target robustness (D99 larger than 95% of the prescribed dose, even for the worst-case scenario), whilst still obtaining a significant plan computation time gain of 57%. Conclusions Two scenario-selection procedures were developed which achieved significant reduction of plan computation time and memory consumption, without compromising plan quality or robustness.
引用
收藏
页码:5434 / 5443
页数:10
相关论文
共 50 条
  • [1] 4D Optimization for Scanned Ion Beam Tracking Therapy for Moving Tumors
    Eley, J.
    Graeff, C.
    Luechtenborg, R.
    Durante, M.
    Howell, R.
    Newhauser, W.
    Bert, C.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3970 - 3970
  • [2] 4D optimization of scanned ion beam tracking therapy for moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Luechtenborg, Robert
    Graeff, Christian
    Bert, Christoph
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13): : 3431 - 3452
  • [3] 4D Optimized Treatment Planning for Actively Scanned Proton Therapy Delivered to Moving Target Volume
    Bernatowicz, K.
    Zhang, Y.
    Weber, D.
    Lomax, A.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3615 - 3615
  • [4] Selection of breathing phase number in 4D scanned proton treatment planning optimization for lung tumors
    Ma, Yuanyuan
    Mao, Jingfang
    Liu, Xinguo
    Dai, Zhongying
    Zhang, Hui
    Li, Yazhou
    Li, Qiang
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
  • [5] Towards a more robust 4D optimization for PBS-based moving tumor treatments
    Zhang, Y.
    Huth, I.
    Weber, D. C.
    Lomax, A. J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S110 - S110
  • [6] Experimental Validation of a 4D Dose Calculation for Scanned Proton Beam Therapy
    Krieger, M.
    Klimpki, G.
    Fattori, G.
    Hrbacek, J.
    Oxley, D.
    Safai, S.
    Weber, D.
    Lomax, A.
    Zhang, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3180 - 3180
  • [7] Treatment planning and 4D robust evaluation for proton therapy of lung tumors with large motion
    Taasti, V.
    Hattu, D.
    Vaassen, F.
    Canters, R.
    Velders, M.
    Mannens, J.
    van Loon, J.
    Rinaldi, I.
    Unipan, M.
    van Elmpt, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S264 - S266
  • [8] Comprehensive Evaluation for 4D Scanned Proton Plans
    Ribeiro, C. O.
    Meijers, A.
    Korevaar, E. W.
    Langendijk, J. A.
    Knopf, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S208 - S208
  • [9] DMLC IMRT to moving tissues - Towards 4D therapy
    Papiez, L.
    McMahon, R.
    Rangaraj, D.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2438 - 2438
  • [10] Quantifying Normal Tissue Sparing with 4D Robust Optimization of Intensity Modulated Proton Therapy
    Newpower, M.
    Ge, S.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3504 - 3505