Determination of three penicillin residues in milk by solid-phase extraction-ultra performance liquid chromatography-tandem mass spectrometry using a covalent triazine framework sorbent

被引:3
|
作者
Li Qin [1 ]
Dai Shuyu [2 ]
Yang Yuan [2 ]
Feng Yumin [2 ]
Lian Hongzhen [3 ]
Zhang Shusheng [2 ]
Zhang Wenfen [2 ,4 ]
机构
[1] Food & Drug Inspect Inst Zhengzhou, Zhengzhou 450006, Peoples R China
[2] Zhengzhou Univ, Coll Chem, Zhengzhou 450001, Peoples R China
[3] Nanjing Univ, Coll Chem & Chem Engn, Nanjing 210023, Peoples R China
[4] China Natl Tobacco Corp, Zhengzhou Tobacco Res Inst, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
covalent triazine frameworks (CTFs); solid-phase extraction (SPE); ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS); penicillin; milk; AMPICILLIN;
D O I
10.3724/SP.J.1123.2022.07002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method based on solid-phase extraction-ultra performance liquid chromatography-tandem mass spectrometry (SPE-UPLC-MS/MS) was established for the determination of gpenicillin, cloxacillin, ampicillin residues in milk. Using self-made covalent triazine frameworks (CTFs) as the solid-phase extraction sorbents, the main factors influencing the efficiency of the solid-phase extraction columns, such as the sorbent amount, eluent type, eluent volume, and flow rate, were optimized. The extraction and purification conditions for the samples were also investigated. The optimal extraction effect was achieved at a flow rate of 3 mL/min with 60 mg CTFs and 6 mL eluent solution (acetonitrile). Separation was carried out on a Waters ACQUITY UPLC BEH C18 column, and 0. 1% formic acid aqueous solution-acetonitrile was used as the mobile phases for gradient elution. The filtrate was detected by ultra performance liquid chromatography-tandem mass spectrometry, identified by electrospray ionization (ESI) in the positive mode using multiple reaction monitoring, and quantified using external standards. The calibration curves of the three penicillins showed good linearity and the correlation coefficients of the linear regression equations for the three target analytes were all greater than 0. 999. The limits of detection (LODs) and limits of quantification (LOQs) were 0. 05 - 0. 10 mu g/kg and 0. 1 - 0.4 mu g/kg, respectively. The average recoveries of the three analytes were 84. 9% - 94. 1%, and the relative standard deviations (RSDs, n = 5) were 1. 66% - 3. 27%. Moreover, the mechanism of interaction between the CTFs and the target analytes was analyzed. The results revealed the existence of pi-pi and hydrogen-bond interactions between the CTFs and analytes. The results further indicated that the CTFs could be successfully used for the enrichment and purification of penicillins in milk. The proposed method has the advantages of high precision, good reproducibility, high resolution, and short analysis time, and it is suitable for the qualitative and quantitative determination of trace targets in complex matrices.
引用
收藏
页码:998 / 1004
页数:7
相关论文
共 28 条
  • [1] [Anonymous], 2008, 22975 GBT
  • [2] [Anonymous], 2007, 21315 GBT
  • [3] Chu H C, 2013, J GUIZHOU NORMAL U N, V31, P77
  • [4] [郝杰 Hao Jie], 2017, [食品科学, Food Science], V38, P266
  • [5] Hou Y F, 2022, FEBS OPEN BIO, V12, P2213
  • [6] Ju S Y, 2018, APPL PHYS A-MATER, V39, P144
  • [7] Li L F, 2013, J DAIRY SCI TECHNOLO, V36, P24
  • [8] Liang JingJing Liang JingJing, 2018, Food and Fermentation Industries, V44, P265
  • [9] Simultaneous determination of 11 prohibited and restricted veterinary drugs and their metabolites in animal -derived foods by ultra performance liquid chromatography-tandem mass spectrometry coupled with solid phase extraction
    Liu Bolin
    Xie Jian
    Zhao Ziwei
    Wang Xiuli
    Shuan Xiaomei
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (04) : 406 - 414
  • [10] Rapid and simultaneous determination of amoxicillin, penicillin G, and their major metabolites in bovine milk by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Liu, Chuangji
    Wang, Hai
    Jiang, Yanbin
    Du, Zhenxia
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (7-8): : 533 - 540