JOINT REPLACEMENTS;
ELASTOHYDRODYNAMIC LUBRICATION;
FRICTION MOMENTS;
WEAR MECHANISMS;
ELASTIC-MODULUS;
METAL BEARINGS;
FILM THICKNESS;
PROSTHESES;
GAIT;
ARTHROPLASTY;
D O I:
10.1371/journal.pone.0071622
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
The tribological performance of an artificial hip joint has a particularly strong influence on its success. The principle causes for failure are adverse short-and long-term reactions to wear debris and high frictional torque in the case of poor lubrication that may cause loosening of the implant. Therefore, using experimental and theoretical approaches models have been developed to evaluate lubrication under standardized conditions. A steady-state numerical model has been extended with dynamic experimental data for hard-on-hard bearings used in total hip replacements to verify the tribological relevance of the ISO 14242-1 gait cycle in comparison to experimental data from the Orthoload database and instrumented gait analysis for three additional loading conditions: normal walking, climbing stairs and descending stairs. Ceramic-on-ceramic bearing partners show superior lubrication potential compared to hard-on-hard bearings that work with at least one articulating metal component. Lubrication regimes during the investigated activities are shown to strongly depend on the kinematics and loading conditions. The outcome from the ISO gait is not fully confirmed by the normal walking data and more challenging conditions show evidence of inferior lubrication. These findings may help to explain the differences between the in vitro predictions using the ISO gait cycle and the clinical outcome of some hard-on-hard bearings, e. g., using metal-on-metal.
机构:
Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USAUniv Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA
Elkins, Jacob M.
O'Brien, Megan K.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USAUniv Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA
O'Brien, Megan K.
Stroud, Nicholas J.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USAUniv Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA
Stroud, Nicholas J.
Pedersen, Douglas R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USAUniv Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA
Pedersen, Douglas R.
Callaghan, John J.
论文数: 0引用数: 0
h-index: 0
机构:
Iowa City Vet Adm Med Ctr, Iowa City, IA USA
Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USAUniv Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA
Callaghan, John J.
Brown, Thomas D.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA
Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USAUniv Iowa, Orthopaed Biomech Lab, Iowa City, IA 52242 USA