Traceability of CDs/DVDs used as retrospective 222Rn detectors to reference STAR laboratory

被引:10
|
作者
Pressyanov, D. [1 ]
Foerster, E. [2 ]
Georgiev, S. [1 ]
Dimitrova, I. [1 ]
Mitev, K. [1 ]
机构
[1] Sofia Univ St Kliment Ohridski, Fac Phys, Sofia, Bulgaria
[2] Fed Off Radiat Protect BfS, Radon Calibrat Serv Lab, Berlin, Germany
关键词
Rn-222; Traceability; CD; DVD; STAR laboratory; Retrospective measurements; RADON; ABSORPTION; POLYCARBONATES; BFS;
D O I
10.1016/j.radmeas.2013.06.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
DVDs need a proper metrological assurance. The specific feature of this method, as compared to other methods for retrospective Rn-222 measurements is the possibility for an individual a posteriori calibration of the used CD/DVD-detectors. This paper describes a procedure to ensure the traceability of this method to a reference STAR laboratory. A set of 7 groups of CDs/DVDs were exposed to 4 reference Rn-222 exposure levels. After that they were treated in the etching laboratory as "real" detectors and the Rn-222 concentrations were determined by applying an individual a posteriori calibration, correction for high track density and correction for depth at which the alpha tracks were etched. The results from all 7 groups of exposed detectors demonstrated relative variation from the reference values in the interval 3.4-23.4%. The results provide evidence that the routine measurements by the CD/DVD method warrant measurements with a relative uncertainty better than 25% and therefore this method is acceptable for large-scale applications. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:165 / 171
页数:7
相关论文
共 50 条
  • [1] Optimization of etching conditions of CDs/DVDs used as detectors for 222Rn
    Pressyanov, D.
    Mitev, K.
    Georgiev, S.
    Dimitrova, I.
    RADIATION MEASUREMENTS, 2015, 83 : 36 - 40
  • [2] Establishment of the 222Rn traceability chain with the Romanian standard system
    Sahagia, M.
    Luca, A.
    Waetjen, A. C.
    Antohe, A.
    Ivan, C.
    Varlam, C.
    Faurescu, I.
    Cassette, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 631 (01): : 73 - 79
  • [3] Study of gel materials as radioactive 222Rn gas detectors
    Espinosa, G.
    Golzarri, J. I.
    Rickards, J.
    Gammage, R. B.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 425 - 429
  • [4] Diffusion Length of Rn-222 in Home-stored CDs/DVDs - Influence on Rn-222 and Rn-220 Measurements
    Dimitrova, Ivelina S.
    Georgiev, Strahil B.
    Pressyanov, Dobromir S.
    Boshkova, Tatiana A.
    Vassileva, Philippa L.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [5] Characteristics of major filters used for 222Rn progeny measurements
    Takeshi, I
    Kenzo, F
    Shinji, T
    Ryuhei, K
    RADIATION MEASUREMENTS, 1998, 29 (02) : 161 - 164
  • [6] The calibration of activated charcoal detectors in a small 222Rn exposure chamber
    Bogacz, J
    Mazur, J
    Swakon, J
    Janik, M
    RADIATION MEASUREMENTS, 2001, 33 (06) : 873 - 878
  • [7] A 222Rn source for low-background liquid scintillation detectors
    Johnson, M
    Benziger, J
    Stoia, C
    Calaprice, F
    Chen, M
    Darnton, N
    Loeser, F
    Vogelaar, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 414 (2-3): : 459 - 465
  • [8] 222Rn absorption in plastic holders for alpha trace detectors:: A source of error
    More, H
    Hubbard, LM
    RADIATION PROTECTION DOSIMETRY, 1997, 74 (1-2) : 85 - 91
  • [9] Long term measurement of the 222Rn concentration in the Canfranc Underground Laboratory
    Amare, J.
    Bandac, I.
    Blancas, A.
    Borjabad, S.
    Buisan, S.
    Cebrian, S.
    Cintas, D.
    Coarasa, I.
    Garcia, E.
    Martinez, M.
    Nunez-Lagos, R.
    Olivan, M. A.
    Ortigoza, Y.
    de Solorzano, A. Ortiz
    Perez, C.
    Puimedon, J.
    Rodriguez, S.
    Salinas, A.
    Sarsa, M. L.
    Villar, P.
    EUROPEAN PHYSICAL JOURNAL C, 2022, 82 (10):
  • [10] Passive integrating 222Rn and 220Rn cup monitors with CR-39 detectors
    Iida, T.
    Nurishi, R.
    Okamoto, K.
    Environment International, 1996, 22 (Suppl 1):