Condition assesment of cable insulation systems in operating nuclear power plants

被引:43
|
作者
Anandakumaran, K [1 ]
Seidl, W
Castaldo, PV
机构
[1] Ontario Hydro Technol, Toronto, ON, Canada
[2] Ontario Hydro Nucl, Toronto, ON, Canada
关键词
This work was partially funded by the Candu Owners Group R&D program; and their support is greatly acknowledged. Technical assistance was provided by T. Mac and C. MacPhee. We also thank J. V. Lind-ley; J; Janis; S; Barreca; and D.J . Stonkus for useful suggestions and comments;
D O I
10.1109/94.775626
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Four crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated cables were subjected to accelerated thermal, radiation, and sequential radiation and thermal exposure to simulate 20, 30, and 40 yr in-service environments in Ontario Hydro Nuclear Plants. Two sets of samples were evaluated. The first set contained 15 cm cable specimens in tubular form with the conductors removed, while the second set was made up of 4.3 m cable samples wound on mandrels, The cable samples were sequentially irradiated and thermally aged and subjected to an additional accident radiation exposure followed by a simulated loss of coolant accident (LOCA)/main steam line break (MSLB) steam test. During the steam test, samples were energized and their electrical characteristics continuously monitored. The material performance of the insulation was assessed using the 15 cm specimens during the various stages of aging exposure by conventional elongation measurement and by the use of micro-specimens with differential scanning calorimeter (DSC), oxidation induction time (OIT) and infrared carbonyl absorption techniques. The results from these samples were compared with the electrical performance of the cable samples wound on mandrels that had been subjected to the LOCA/MSLB steam test. The test results indicate that with the use of micro-specimens meaningful changes were obtained until the elongation values of the samples were reduced to 50% absolute. Electrical test data obtained for XLPE and EPR during the steam tests indicate that 50% absolute elongation values provide sufficient margin to withstand additional accident radiation, and to function electrically during design basis events.
引用
下载
收藏
页码:376 / 384
页数:9
相关论文
共 50 条
  • [1] Cable condition monitoring for nuclear power plants
    Analysis and Measurement Services Corporation, AMS Technology Center, 9119 Cross Park Drive, Knoxville, TN 37923, United States
    FIIW - Future Instrum. Int. Workshop Proc., (97-100):
  • [2] Research Progress and Prospect of Cable Insulation in Nuclear Power Plants
    Gao Y.
    Liu B.
    Du B.
    Liang G.
    Sun J.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (02): : 449 - 460
  • [3] ELECTRIC CABLE INSULATION FOR NUCLEAR-PLANTS
    NOBLE, MG
    POWER ENGINEERING, 1976, 80 (07) : 60 - 63
  • [4] ELECTRIC CABLE INSULATION FOR NUCLEAR PLANTS.
    Noble, Maynard G.
    Power Engineering (Barrington, Illinois), 1976, 80 (07): : 60 - 63
  • [5] Issues of operating systems usage for nuclear power plants
    Andryushin, Alexander
    Durnev, Vladimir
    Chernyaev, Alexey
    ANNALS OF NUCLEAR ENERGY, 2014, 70 : 87 - 89
  • [6] Aging investigation of low-voltage cable insulation used in nuclear power plants
    Fabiani, Davide
    Suraci, Simone V.
    Bulzaga, Stefano
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 516 - 519
  • [7] Aging investigation of low-voltage cable insulation used in nuclear power plants
    Verardi, L.
    Fabiani, D.
    Montanari, G. C.
    Gedde, U. W.
    Linde, E.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 851 - 854
  • [8] A Condition Assesment Applied for Semi-Conductive Layer of Power Cable
    Park, Hwi-Gon
    Heo, Jee-Hyeok
    Lee, Seung-Won
    Kim, Su-Hwan
    Lim, Jang-Seob
    Lee, Kun-Ho
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 659 - 661
  • [9] Aging and condition monitoring studies of composite insulation cables used in nuclear power plants
    Anandakumaran, K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (01) : 227 - 237
  • [10] Electrical Aging Markers for Low-Voltage Cable Insulation Wiring of Nuclear Power Plants
    Verardi, L.
    Fabiani, D.
    Montanari, G. C.
    Placek, V.
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,