Fracture evolution in concrete compressive fatigue experiments based on X-ray micro-CT images

被引:33
|
作者
Skarzynski, L. [1 ]
Marzec, I [1 ]
Tejchman, J. [1 ]
机构
[1] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
关键词
Micro-CT; Plain concrete; Cyclic compression; Fatigue; Fracture; HIGH-STRENGTH; COHESIVE ELEMENTS; AGGREGATE LEVEL; DAMAGE MODEL; BEHAVIOR; PLAIN; DEM;
D O I
10.1016/j.ijfatigue.2019.02.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study examines the fatigue performance of plain concrete specimens under uniaxial compression. The experimental program was developed for investigating the fracture evolution in concrete cubic specimens subjected to cyclic compression using the advanced X-ray micro-computed tomography system SkyScan 1173. As compared to other experiments, the 3D micro-CT damage images were shown for a various number of loading cycles. The quantitative evolution of the cracking volume with increasing fatigue damage revealed a strongly non-linear shape. The increase of the total crack volume was higher by 30% as compared to the monotonic fatigue test.
引用
收藏
页码:256 / 272
页数:17
相关论文
共 50 条
  • [1] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [2] Fatigue damage evolution in asphalt mixture based on X-ray CT images
    Shan, Liyan
    Yang, Hu
    Guo, Fuyuan
    Li, Zhiwei
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 358
  • [3] X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT
    Kim, Jae G.
    Park, So E.
    Lee, Soo Y.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 63 - 75
  • [4] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [5] Automated Segmentation of Murine Lung Tumors in X-ray micro-CT Images
    Swee, Joshua K. Y.
    Sheridan, Clare
    de Bruin, Elza
    Downward, Julian
    Lassailly, Francois
    Pizarro, Luis
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [6] A realistic projection simulator for laboratory based X-ray micro-CT
    Dhaene, Jelle
    Pauwels, Elin
    De Schryver, Thomas
    De Muynck, Amelie
    Dierick, Manuel
    Van Hoorebeke, Luc
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 342 : 170 - 178
  • [7] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [8] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [9] X-ray Micro-CT based characterization of rock cuttings with deep learning
    Olsen, Nils
    Chen, Yifeng
    Turberg, Pascal
    Moreau, Alexandre
    Alahi, Alexandre
    APPLIED COMPUTING AND GEOSCIENCES, 2025, 25
  • [10] Accurate Resolution Measurement for X-Ray Micro-CT Systems
    Sen Sharma, K.
    Seshadri, S.
    Feser, M.
    Wang, G.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 337 - 340