Pain reduced by low-level laser therapy during use of orthodontic separators in early mixed dentition

被引:0
|
作者
Stein, Steffen [1 ]
Korbmacher-Steiner, Heike [1 ]
Popovic, Nenad
Braun, Andreas [2 ]
机构
[1] Univ Marburg, Dept Orthodont, D-35039 Marburg, Germany
[2] Univ Marburg, Dept Operat Dent, D-35039 Marburg, Germany
关键词
Low-level laser therapy; Orthodontics; Separation; Children; Pain; IBUPROFEN; IRRADIATION; DISCOMFORT; PERCEPTION; EFFICACY; LLLT;
D O I
10.1007/s00056-015-0306-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this work was to investigate whether low-level laser therapy (LLLT) applied at a defined distance from the gingiva has a pain-reducing effect in young patients undergoing orthodontic separation during the early mixed-dentition stage. A total of 40 children in early mixed dentition (mean age 8.05 years) who required separation of molars were included. The study comprised a group of 20 patients whose treatment included laser application on the day of separation and a control group of 20 patients not receiving LLLT. All patients recorded their maximum pain intensities on the day of separation (day 1) and on the following 4 days. Compared to the control group, pain perception was significantly reduced (p < 0.05) in the LLLT group on day 1 and continued to be reduced on day 2. Equivalent pain levels were recorded in both groups on days 3-5. Given our findings of a pain-reducing effect in young patients undergoing orthodontic separation during the early mixed-dentition stage, LLLT is an interesting alternative option of providing analgesia even in very young patients.
引用
收藏
页码:431 / 439
页数:9
相关论文
共 50 条
  • [1] Pain reduced by low-level laser therapy during use of orthodontic separators in early mixed dentition [Schmerzreduktion bei der Verwendung von kieferorthopädischen Separatoren durch Low-Level-Lasertherapie im frühen Wechselgebiss]
    Stein S.
    Korbmacher-Steiner H.
    Popovic N.
    Braun A.
    Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2015, 76 (5): : 431 - 439
  • [2] Low-level laser therapy for controlling pain in orthodontic patients during the use of elastic separators: randomized clinical trial
    Farias, Rodrigo Duarte
    Motta, Rogerio Heladio
    LASER PHYSICS LETTERS, 2018, 15 (09)
  • [3] The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators
    Ladan Eslamian
    Ali Borzabadi-Farahani
    Aidin Hassanzadeh-Azhiri
    Mohammad R. Badiee
    Reza Fekrazad
    Lasers in Medical Science, 2014, 29 : 559 - 564
  • [4] The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators
    Eslamian, Ladan
    Borzabadi-Farahani, Ali
    Hassanzadeh-Azhiri, Aidin
    Badiee, Mohammad R.
    Fekrazad, Reza
    LASERS IN MEDICAL SCIENCE, 2014, 29 (02) : 559 - 564
  • [5] Low-level laser therapy for orthodontic pain: a systematic review
    Li, F. J.
    Zhang, J. Y.
    Zeng, X. T.
    Guo, Y.
    LASERS IN MEDICAL SCIENCE, 2015, 30 (06) : 1789 - 1803
  • [6] Low-level laser therapy for orthodontic pain: a systematic review
    F. J. Li
    J. Y. Zhang
    X. T. Zeng
    Y. Guo
    Lasers in Medical Science, 2015, 30 : 1789 - 1803
  • [7] The Use of Low Level Laser Therapy for Pain Reduction During Fixed Orthodontic Treatment
    Pesevska, Snezana
    Maneva, Marija
    Ivanovski, Kiro
    Pandilova, Maja
    Georgieva, Silvana
    Mindova, Sonja
    Ristoska, Stevica
    Stefanovska, Emilija
    Cuckova, Gabriela Curcieva
    Apostolova, Gordana
    Apostolova, Elena
    Koneski, Filip
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2016, 7 (06): : 1004 - 1009
  • [8] Efficiency of Low-Level Laser Therapy in Reducing Pain Induced by Orthodontic Forces
    Bicakci, Ali Altug
    Kocoglu-Altan, Burcu
    Toker, Hulya
    Mutaf, Ilhan
    Sumer, Zeynep
    PHOTOMEDICINE AND LASER SURGERY, 2012, 30 (08) : 460 - 465
  • [9] LOW-LEVEL LASER THERAPY PROTOCOLS IN DENTAL MOVEMENT ACCELERATION AND IN PAIN MANAGEMENT DURING ORTHODONTIC TREATMENT
    Caccianiga, G.
    Lo Giudice, A.
    Longoni, S.
    Ceraulo, S.
    Baldoni, M.
    Leonida, A.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (06): : 59 - 68
  • [10] The effect of diode superpulsed low-level laser therapy on experimental orthodontic pain caused by elastomeric separators: a randomized controlled clinical trial
    Ida Marini
    Maria Lavinia Bartolucci
    Francesco Bortolotti
    Giulio Innocenti
    Maria Rosaria Gatto
    Giulio Alessandri Bonetti
    Lasers in Medical Science, 2015, 30 : 35 - 41